background image

Property of Ultrasonic Power Corporation - © 2019 
Publication # 190610

 

 

 

 
 

Sonic Touch II® (PPC30) User Manual 

 
 
 
 

 

 
 
 
 
 
 

Ultrasonic Power Corporation 

239 E. Stephenson Street 

Freeport, IL 61032, U.S.A. 

Phone: 815-235-

6020 • 1-800-575-0168 

Fax: 815-232-2150 

 

Email: 

sonic@upcorp.com

 

 

www.upcorp.com

 

 

Summary of Contents for Sonic Touch II

Page 1: ...poration 2019 Publication 190610 Sonic Touch II PPC30 User Manual Ultrasonic Power Corporation 239 E Stephenson Street Freeport IL 61032 U S A Phone 815 235 6020 1 800 575 0168 Fax 815 232 2150 Email...

Page 2: ...aspects of the system configuration prior to start up We know that your Ultrasonic Power Corporation cleaning system will serve you for years to come Thank You again for selecting Ultrasonic Power Co...

Page 3: ...r Login 14 8 Setup 16 9 Alarms 17 10 Alarm history 19 11 Frequency Display 20 12 Power Output Display 21 13 Ultrasonics Configuration 22 14 Heat Configuration 28 15 Pump Configuration Optional 34 16 S...

Page 4: ...amage injury and or death High Voltage Proper Voltage Failure to comply with this safety statement may result in equipment damage injury and or death Caution Moving Parts Failure to comply with this s...

Page 5: ...2 W Max Without USB Interface Reverse Polarity Protection Dimensions W x H x D 7 8 in x 5 5 in x 2 in Weight 1 433 lbs IF 1 USB 2 0 Type A 0 49 A IF 2 USB 2 0 Type A 0 49 A IF 3 Ethernet 1x RJ45 shiel...

Page 6: ...care Wear grounding strap and or properly rated footwear Upon power up of the system the panel will cycle through the loading screen as seen in the image At this time you may choose to calibrate touch...

Page 7: ...BRATION The touch calibration page allows the user to increase the touch control accuracy should it fall out of calibration To calibrate touch control press the visible target with your finger A secon...

Page 8: ...the home screen for the Sonic Touch II This page allows the user start stop control for configured peripherals ultrasonic intensity control frequency sweep control temperature control and displays al...

Page 9: ...ic Power Corporation 2019 Publication 190610 6 BASIC NAVIGATION CONTROL Every page contains these common features navigation button 1 home button 2 user login button 3 back button 4 and an error refre...

Page 10: ...y of Ultrasonic Power Corporation 2019 Publication 190610 Pressing the back button reverts the user to the previous page if any Pressing the home button from any other page will direct the user to the...

Page 11: ...rporation 2019 Publication 190610 The error refresh button clears addressed errors alarms This button will only function if the errors alarms have been corrected Errors alarms will be examined in furt...

Page 12: ...the user to view the options accessible at the current permissions level The figure below displays the options available at the Supervisor permission level Not all of these features are available in t...

Page 13: ...n 2019 Publication 190610 Pressing the user login shortcut will direct the user to the login page The figure below displays the user login page Information regarding login information will be examined...

Page 14: ...pervisor permission allows full access to all features and capabilities including those of Operator permission The user login page displays from top to bottom password entry logout button the current...

Page 15: ...d will display ready to accept the password once entered Upon entering the desired password press the enter return button in the bottom right corner of the keypad _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Page 16: ...er Mode may be toggled on in order to disable low liquid level protection for the usage of high quality DI water This mode is only for usage if the system is otherwise incapable of running due to an i...

Page 17: ...bottom of every page and in the alarm page itself Potentially common active errors alarms include not limited to 1 Output Power Error This error occurs if one or more outputs experiences an issue 2 L...

Page 18: ...button If multiple alarms are active they can be viewed form the alarms page Up down arrows are used to navigate through the alarms and the alarms page contains and additional error refresh button loc...

Page 19: ...Property of Ultrasonic Power Corporation 2019 Publication 190610 10 ALARM HISTORY The alarm history page allows the user to view past active alarms Up down arrows are used to navigate through the alar...

Page 20: ...Caution Ensure tank contains the minumum required amount of liquid prior to operation Warning Ensure proper drainage or liquid removal is installed prior to operation The values displayed here are mea...

Page 21: ...onal location to adjust power intensity Caution Ensure tank contains the minumum required amount of liquid prior to operation Warning Ensure proper drainage or liquid removal is installed prior to ope...

Page 22: ...ows the user to operate the peripheral directly from the home screen 2 Timer Countdown allows the peripheral to operate for a predetermined amount of time 9 59 59 maximum 3 Schedule 7 Day Timer allows...

Page 23: ...23 Property of Ultrasonic Power Corporation 2019 Publication 190610 The currently set mode is displayed below the...

Page 24: ...0 This configuration page may be accessed by pressing the on the main page or via the navigation window To cycle between operation modes press the dial once with your finger Each time the dial is pres...

Page 25: ...ower Corporation 2019 Publication 190610 In manual mode the user may enable the peripheral by pressing in either of the two locations highlighted in red The Run button starts the peripheral The Reset...

Page 26: ...red The time may be entered via the up down arrows or by pressing the numeric windows The Run button starts the peripheral The Reset button stops the peripheral and resets the time to the value previ...

Page 27: ...r location highlighted in red Start and stop times may be entered via the up down arrows or by pressing the numeric windows The day to be programmed is changed via the drop down window If a day is to...

Page 28: ...user to operate the peripheral directly from the home screen 2 Timer Countdown allows the peripheral to operate for a predetermined amount of time 9 59 59 maximum 3 Schedule 7 Day Timer allows the pe...

Page 29: ...29 Property of Ultrasonic Power Corporation 2019 Publication 190610 The currently set mode is displayed below the...

Page 30: ...0 This configuration page may be accessed by pressing the on the main page or via the navigation window To cycle between operation modes press the dial once with your finger Each time the dial is pres...

Page 31: ...ower Corporation 2019 Publication 190610 In manual mode the user may enable the peripheral by pressing in either of the two locations highlighted in red The Run button starts the peripheral The Reset...

Page 32: ...red The time may be entered via the up down arrows or by pressing the numeric windows The Run button starts the peripheral The Reset button stops the peripheral and resets the time to the value previ...

Page 33: ...her location highlighted in red Start and stop times may be entered via the up down arrows or by pressing the numeric windows The day to be programmed is changed via the drop down window If a day is t...

Page 34: ...s the user to operate the peripheral directly from the home screen 2 Timer Countdown allows the peripheral to operate for a predetermined amount of time 9 59 59 maximum 3 Schedule 7 Day Timer allows t...

Page 35: ...35 Property of Ultrasonic Power Corporation 2019 Publication 190610 The currently set mode is displayed below the...

Page 36: ...mation and pump system the liquid will fall below the Low Liquid Level sensor and trigger an error By holding this button the user is capable of running the pump even while this error is in effect Thi...

Page 37: ...37 Property of Ultrasonic Power Corporation 2019 Publication 190610 In manual mode the user may enable the peripheral by pressing in either of the two locations highlighted in red...

Page 38: ...asonic Power Corporation 2019 Publication 190610 The Run button starts the peripheral The Reset button stops the peripheral In Timer mode the user may input the time value by pressing either location...

Page 39: ...tton starts the peripheral The Reset button stops the peripheral and resets the time to the value previously entered Pressing this button again clears the value The time value may be increased decreas...

Page 40: ...ia the up down arrows or by pressing the numeric windows The day to be programmed is changed via the drop down window If a day is to be disabled set the start and stop times equal to each other This i...

Page 41: ...directly from the home screen 2 Timer Countdown allows the peripheral to operate for a predetermined amount of time 9 59 59 maximum 3 Schedule 7 Day Timer allows the peripheral to operate via a 7 day...

Page 42: ...of Ultrasonic Power Corporation 2019 Publication 190610 This configuration page may be accessed by pressing the on the main page or via the navigation window To cycle between operation modes press th...

Page 43: ...2019 Publication 190610 with your finger Each time the dial is pressed the system will index through each mode in a single direction In manual mode the user may enable the peripheral by pressing in ei...

Page 44: ...asonic Power Corporation 2019 Publication 190610 The Run button starts the peripheral The Reset button stops the peripheral In Timer mode the user may input the time value by pressing either location...

Page 45: ...tton starts the peripheral The Reset button stops the peripheral and resets the time to the value previously entered Pressing this button again clears the value The time value may be increased decreas...

Page 46: ...via the up down arrows or by pressing the numeric windows The day to be programmed is changed via the drop down window If a day is to be disabled set the start and stop times equal to each other This...

Page 47: ...thin the working volume of the tank Intensity and sweep controls are located on this page for convenience while attempting to optimize performance within the tank Caution Ensure tank contains the minu...

Page 48: ...ormance levels inside the tank Variables include but are not limited to 1 Power intensity 2 Frequency sweep 3 Water Composition 4 Liquid Level Temperature 5 Surfactant Solution Ratio 6 Containment Bou...

Page 49: ...n 190610 18 MACHINE STATS The machine stats page allows the user to view elapsed time meter for multiple components of the system The filter elapsed time meter holds the ability to be reset This featu...

Page 50: ...g page allows the user to download recorded data onto a flash drive FAT32 format at least 1 GB This is a list of parameters that the system records whenever the ultrasonics are on 1 Timestamp 2 LCS 3...

Page 51: ...d information will be made visible The USB device is automatically ejected following a download Downloaded information may be viewed as a spreadsheet using Microsoft Excel The save interval of the dat...

Page 52: ...he SDM includes 1 System information 2 Software information 3 Hardware information 4 Motion information 5 Logger information 6 Profiler information 7 System dump feature The SDM houses the System Dump...

Page 53: ...2019 Publication 190610 21 DIAGNOSTICS SYSTEM DUMP INSTRUCTIONS Insert a USB or other device into the USB port and look to the USB Log Backup page Once the system recognizes the device alternate optio...

Page 54: ...54 Property of Ultrasonic Power Corporation 2019 Publication 190610 Redirect to the SDM found in the diagnostics page Select the orange System Dump tile Select a system dump option...

Page 55: ...on 2019 Publication 190610 Confirm the system dump option selection Allow the system 10 15 seconds for the system dump to take place The loading bar will remain at 0 for the entirety of this operation...

Page 56: ...56 Property of Ultrasonic Power Corporation 2019 Publication 190610 Confirm the abort selection At this point the page should state that the system dump is already completed Select continue...

Page 57: ...to the SDM page Again select the orange System Dump tile At this point the user will have the option to perform another system dump in which case the previous steps are repeated by selecting Ok Other...

Page 58: ...y save to a USB or another external device The other folders located in this page house internal data pertinent to the system The figure below displays a USB flash drive as MY_USB this name may not al...

Page 59: ...2019 Publication 190610 Once the folder is selected files stored in the device will be displayed In this case a previously stored system dump and data logging files exist Press the disk image or Save...

Page 60: ...Power Corporation 2019 Publication 190610 Upon a successful download press Continue Revert to the USB Log Backup page and press Eject USB The USB flash drive may then be uninstalled for further troubl...

Page 61: ...r Customer if the first Purchaser is a distributor only and is not otherwise transferable without the prior written consent of UPC THIRD PARTY COMPONENT WARRANTY Concerning any products and components...

Page 62: ...r component which has been i incorrectly operated or misused ex operating the equipment dry dropping heavy objects into the cleaning tank incorrect voltage connections ii altered or iii modified d exp...

Page 63: ...ardless of any other agreement between the first Purchaser or Customer if the first Purchaser is a distributor and UPC this Warranty will be governed and controlled in all respects by the laws of the...

Page 64: ...f the first Purchaser is a distributor place of business using a transportation method of its choosing or through consultation with the first Purchaser or Customer if the first Purchaser is a distribu...

Page 65: ...y Policy All warranty repairs are subject to an initial inspection and approval by an authorized UPC repair representative to determine if the requested repairs are covered by an applicable UPC Warran...

Page 66: ...in the Pricing Schedule Shipping Expenses Abandoned Product Failure to Authorize Repair in Timely Manner Shipping expenses are the responsibility of the customer UPC recommends a shipping method which...

Page 67: ...equipment must be completed UPC reserves the right to refuse acceptance of equipment A 95 hour Cleaning Fee will be assessed for the cleaning of equipment that is considered by UPC to be excessively d...

Page 68: ...icated above all product returns for service must have a RMA number prior to shipment to UPC Product without an RMA number will be refused Please ship with shipment costs pre paid to Ultrasonic Power...

Page 69: ...Evaluation Fee 145 00 Waived with warranty replacement due to defect NON Warranty 600 00 Expired warranty equipment malfunction customer damage Repair Rates for Immersible Transducers Comments Warran...

Page 70: ...ms Comments Warranty Repair 0 00 UPC Warranty Applies Test Evaluation Fee 300 00 Waived with warranty replacement due to defect NON Warranty Quote Expired warranty equipment malfunction customer damag...

Page 71: ...of Ultrasonic Power Corporation 2019 Publication 190610 From RMA Ship To Ultrasonic Power Corporation 239 East Stephenson Street Freeport IL 61032 Attention RMA Coordinator cut here FRAGILE ELECTRONI...

Page 72: ...72 Property of Ultrasonic Power Corporation 2019 Publication 190610 Please contact your Ultrasonic Power Corporation representative with any question regarding your Ultrasonic cleaning system...

Reviews: