LSG Low Smoke Generator 

w/ Power Fog Industrial 9D

Operator’s Manual

www.ultratecfx.com

VER.

 04.11.12

Summary of Contents for LSG PFI-9D

Page 1: ...LSG Low Smoke Generator w Power Fog Industrial 9D Operator s Manual www ultratecfx com VER 04 11 12...

Page 2: ...ating Procedure w Air Option 6 Operation Procedure LSG MK II High Pressure w 20 50lbs Cylinders 7 Figure A 8 Operation Procedure LSG MK II Low Pressure w 350lbs Dewar Tank 9 Figure B 10 Options 11 Opt...

Page 3: ...fering from asthma or allergenic sensitivity may experience irritation discomfort or allergic symptoms when exposed to fog effects 4 Ensure that this unit is grounded at all times Failure to do so may...

Page 4: ...Volt High Pressure PFI 9D System w Road Case CLF 4427 LSG Low Smoke Generator PFI 9D 220 240 Volt High Pressure PFI 9D System w Road Case LSG PFI 9D System on a Cart CLF 4431 LSG Low Smoke Generator...

Page 5: ...www ultratecfx com 5 LSG PFI 9D System in a Roadcase 39 5 28 75 34 5 23 25 29 6 24 20 36 32 2 22 28 02 LSG w PFI 9D Technical Drawings LSG PFI System on a Cart...

Page 6: ...s the fog machine will be fully heated and is ready for full output the indicator will be on solid 6 It may be necessary to prime fluid into the system to expel any air The Variflow control on the rem...

Page 7: ...cure all cylinders to prevent tipping hazards 4 An LSG MK II High Pressure requires high pressure CO2 cylinders These are normally available in 20 50lb sizes It is recommended that cylinders equipped...

Page 8: ...MK II to depressurize the system before attempting to disconnect hoses Note that the valves and lines may be extremely cold during operation Prevent handling and flexing of lines when chilled Figure A...

Page 9: ...intain the liquid at 50C These tanks provide the best performance and price characteristics of the LSG systems Check with your local gas supplier for availability as not every location may carry these...

Page 10: ...ger the LSG MK II to depressurize the system before attempting to disconnect the hoses Note that the valves and lines may be extremely cold during operation Prevent handling and flexing of lines when...

Page 11: ...Adapter CXP 1046 is available This adapter is compatible with the Power Fog Industrial Power Fog Industrial w Air Option Power Fog Industrial 9D and Power Fog Industrial 9D w Air Option Optional Show...

Page 12: ...ready to operate but still in heating mode fog is not available at this point Quick Flashing Light Indicates unit is ready to operate but still in heating mode some fog is available at this point Soli...

Page 13: ...e dry and odorless Pro Beam Long Lasting Fog Fluid With a hang time 2 3x greater than the Director s Choice Fog Fluid the Pro Beam solution produces a slightly less white fog while remaining clean dry...

Page 14: ...y is based on destination of the original sale Any additional costs incurred are the responsibility of the Dealer and or the customer Abuse or poor maintenance is not accepted Proof of purchase or pro...