II. Overview

UT261B Phase Sequence and Motor Rotation Indicator (hereinafter referred to be as UT261B) is a 

handheld battery powered instrument, widely used to identify phase orientation of three-phase industrial 

equipments and motor rotation direction.

 

 

III. Unpacking Inspection

 

IV . Safety Information

      

Caution:

  Specifies the conditions and actions that may cause damage to UT261B.

     

 Warning:

 Specifies the conditions and actions that may pose hazards to the User.

 

To prevent electric shocking or fire, it is necessary to comply  with the following codes:

 

 

 It is required to read through following safety instructions prior to operation or maintenance

  

 Comply with local and national safety codes; 

 It is required to use personal protective equipments; 

 It is required to operate the instrument as per the instructions of manufacturer, or otherwise the safety 

 features/protective measures provided by the instrument may be affected;   

    

 Inspect the insulator of testing lead for damage or exposed metal; inspect testing lead for continuity 

 and replace the damaged testing lead.  

 Please take extreme caution when working with voltage higher than 30Vacrms, 42Vac Peak or 60Vdc, 

 for it may pose electric hazard. 

 

    

 Keep finger away from alligator clip contact and behind the finger protection device when using 

 alligator clip. 

 

 Adverse impact will be caused to the measurement by the impedance  generated by  the transient 

 current of extra operating circuit in parallel;  

 

   

 Please ensure the instrument operates normally prior to measuring dangerous voltage (30V ac rms, 

 42 V AC peak value or 60 V DC above)

 

    

 

Testing time should not exceed 10min when measuring the voltage 500V ~ 600V AC above;  

 Do not operate UT261B when removing any part; 
 Do not operate UT261B around explosive gas, steam or dust; 

 Do not operate UT261B in a wet place; 
 It is required to remove testing lead from the power and UT261B prior to replacing the  battery.  

V. Functional Description 

5.1 Symbols

Following symbols are applied on UT261B or in the manual.

CAT  III

Risk of electric shock 
Warning 
Dangerous voltage 
Double or reinforced insulation
Grounding 
AC or DC
Comply with European Union directives 

Conforms to Overvoltage Category III, Pollution Degree 2 as per 

IEC61010-1. CATIII refers to the degree of protection against the 

transients and usually includes the equipments in fixed installations 

(eg: electricity meter and primary overcurrent protection device).

5.2 Instrument Description

See the instrument indicator, button and jack as shown in Figure 1:

Graphical description

Phase input jack (U, V, W); 
L1, L2, L3 phase indicators; 
Clockwise rotation LED indicator; 
Counter-clockwise rotation LED indicator;

Power switch 
Motor location indicator
Power LED indicator 
Instruction Table

Check the product for any crack or scratch. If any item is missing or damaged, please contact nearby 

UNIT service center.
Standard items included in the shipment:

  The Instrument-----------------------------1 pc

  Operating Manual-------------------------1pc

  Test Leads----------------------------------3pcs

  Alligator Clips-------------------------------3pcs

  Carrying Bag--------------------------------1pc

  9V Battery------------------------------------1pc