background image

1. VERSION  GB 

GHISS  16, 24, 32, 40, 48, 56 R AP 

GHISS  16, 24, 32, 40, 48, 56 R AE 

GHISS  16, 24, 32, R AP PV 

GHISS  16, 24, 32, R AE PV 

GHISS  16, 24, 32, 40, B AP 

GHISS  16, 24, 32, 40, B AE 

GHISS  16, 24, 32, B AP PV 

GHISS  16, 24, 32, B AE PV 

®

USER’S MANUAL AND 
OPERATING INSTRUCTIONS 

STANDARD GAS DEVICE WITH 
CAST-IRON SEGMENTED HEAT-
EXCHANGER, WITH DIRECT 
SPARK IGNITION (AE), 
AND PIEZO IGNITION (AP) 

Summary of Contents for GHISS 16R AE

Page 1: ...24 32 R AP PV GHISS 16 24 32 R AE PV GHISS 16 24 32 40 B AP GHISS 16 24 32 40 B AE GHISS 16 24 32 B AP PV GHISS 16 24 32 B AE PV USER S MANUAL AND OPERATING INSTRUCTIONS STANDARD GAS DEVICE WITH CAST IRON SEGMENTED HEAT EXCHANGER WITH DIRECT SPARK IGNITION AE AND PIEZO IGNITION AP ...

Page 2: ...mation we presented on the following pages carefully and keep it because you will need it later too If you take our advice our product will serve you reliably for long years to come TABLE OF CONTENTS GENERAL Suitability 2 Devices 2 Important details to know 3 Basic safety rules 3 General introduction 4 Identification 4 Construction 4 Technical data 6 Hydraulic operation 8 Pump 9 Electric connectio...

Page 3: ...a year The present operating instructions contains all the important information in connection with the use of the device for the user therefore it is practical to keep it close to the boiler If the device is sold or relocated it should always be accompanied by the operating instructions so that the new owner and or repairman could get sufficient information BASIC RULES OF SAFETY The user is to pa...

Page 4: ...pump on building heating side automatic de airing valve closed expansion tank and safety blow off valve or the version without those made for already existing heating systems Its hot water container has an absolutely hygienic water space provided with double enamel coating and high output magnesium anode protection For protection against over pressure originating from the expansion of hot water fo...

Page 5: ...rd pipe 12 Gas pipe 13 Gas valve 14 Ignition controller only on AE type 15 Ignition electrode 16 Nozzle holding collector 17 Pressure meter 18 Draining tap 19 Expansion tank 20 Filling tap 21 100 l tank 22 Hot water for use draining tap The construction and main parts of GHISS B AP and GHISS B AE type devices are the following The construction and main parts of GHISS B AP PV és GHISS B AE PV type ...

Page 6: ...e mbar 25 Burner nozzle pressure H mbar 12 8 12 5 11 6 12 11 5 11 5 Burner nozzle pressure S mbar 14 5 13 5 12 5 13 12 5 13 Burner nozzle diameter H Ø mm 2 35 2 35 2 35 2 35 2 45 2 45 Burner nozzle diameter S Ø mm 2 6 2 6 2 6 2 6 2 6 2 7 Amount of fuel H M3 h 1 6 2 5 3 4 4 3 5 2 6 1 Amount of fuel S M3 h 2 0 2 9 3 9 5 0 6 0 7 1 Tanked PB gas Connecting gas pressure mbar 28 30 Burner nozzle pressur...

Page 7: ...ter pressure bar 6 6 6 6 Container test overpressure bar 10 10 10 10 Gas technical data Classification according to gas used II2H S3B P Piped natural gas Connecting gas pressure mbar 25 Burner nozzle pressure H mbar 12 8 12 5 11 6 12 Burner nozzle pressure S mbar 14 5 13 5 12 5 13 Burner nozzle diameter H Ø mm 2 35 2 35 2 35 2 35 Burner nozzle diameter S Ø mm 2 6 2 6 2 6 2 6 Amount of fuel H m3 h ...

Page 8: ...SS R AE PV type devices Legends 1 Forward 2 Return 3 Gas 4 Network water 5 Draining 6 Filling up 7 Hot water for use 8 Circulation 9 Hot water for use drainage 10 Boiler thermostat 11 Restricting thermostat 12 Thermometer The hydraulic switching of GHISS B AP and GHISS B AE type devices The hydraulic switching of GHISS B AP PV and GHISS B AE PV type devices ...

Page 9: ...n save electric energy The pressure loss of PV type boilers Upon the first start up of the boiler and after a longer shut down it is practical to check the turnability of the axle of the pump with the help of a screwdriver It is forbidden to operate the pump without water The hydraulic loss of the boilers With the exception of the GHISS PV type devices there is no heating circulation pump in the d...

Page 10: ...at F B T Smoke gas safety thermostat F T Fixed thermostat SZ T Room thermostat N Neutral conductor F SZ Heating circulation pump L Phase conductor L J Indicator lamp flame indicator PE Protective grounding 1L Gas magnetic valve switched phase K H J Error indication of restrictors BVE Boiler control unit Supplementary unit necessary for the connection of the indirect container In case of connection...

Page 11: ...oke gas safety thermostat F T Fixed thermostat SZ T Room thermostat N Neutral conductor F SZ Heating circulation pump L Phase conductor L J Indicator lamp flame indicator PE Protective grounding 1L Gas magnetic valve switched phase K H J Error indication of restrictors BVE Boiler control unit Supplementary unit necessary for the connection of the indirect container In case of connection the wire i...

Page 12: ...ometer 2 Smoke gas restricting thermostat 3 Temperature restricting thermostat 4 Main switch 5 Winter Summer switch 6 Mode of operation indicator lamp 7 Error indicator lamp 8 Reset button lighted 9 Boiler temperature setting button 10 Hot water for use temperature setting button ...

Page 13: ...ilot light burner by pressing the piezo ignition 2 3 times then release the button after 15 20 seconds If switching on is unsuccessful it is to be repeated in 2 minutes required for the short ventilation of the combustor After the device has been started up you can check the existence of the pilot light through the spy hole By slightly pushing in the control button of the combined gas valve turn i...

Page 14: ... Set the boiler regulating thermostat 9 according to the desired temperature Set the mode of operation switch 5 according to the desired mode of operation and turn it on Winter mode of operation heating and the production of hot water for use at the indirect container connected to the boiler and on GHISS B devices I Summer mode of operation the production of hot water for use with the indirect con...

Page 15: ...then turn on again the exterior separator switch of the boiler o Check the setting of the room thermostat and carry out on it a switching on and a switching off o Check the setting of the boiler temperature regulator and set it at the desired temperature o Put the winter summer switch into winter position I In case of the GHISS B type in the summer setting the boiler only produces hot water for us...

Page 16: ...t or the room thermostat goes off o In the event of an ignition error the illuminated reset button is lit in red AE o The procedure of re starting is the following press the reset button wait until the ignition procedure is repeated and operation starts If the start up procedure is unsuccessful again re starting can be repeated after 1 2 minutes The number of repeated re starts can be maximum 3 Af...

Page 17: ...at at minimum o Set the room thermostat at 10 C SHUTTING DOWN FOR A LONGER PERIOD OF TIME In this case the following is to be done o Turn off the main switch of the boiler the green light goes off o Turn off the external separation switch of the boiler o Turn off the gas tap If there is a danger of freezing drain the heating water and the water from the hot water for use system CLEANING The outer ...

Page 18: ... carefully and abide by the advice and instructions described The external deflector belonging to the GHISS R 48 and 56 devices are attached in a separate box SIZES AND WEIGHT GHISS 16 24 32 40 R GHISS 48 56 R Type GHISS 16 R GHISS 16 R PV GHISS 24 R GHISS 24 R PV GHISS 32 R GHISS 32 R PV GHISS 40 R GHISS 48 R GHISS 56 R A 410 485 560 635 710 785 Mm B 195 232 5 270 307 5 345 382 5 Mm C 130 130 130...

Page 19: ... B AP GHISS B AE GHISS B AP PV GHISS B AE PV Type GHISS 16 B GHISS 16 B PV GHISS 24 B GHISS 24 B PV GHISS 32 B GHISS 32 B PV GHISS 40 B A 635 635 635 635 mm B 317 5 317 5 317 5 317 5 mm C 130 130 130 150 mm D 105 105 105 125 mm Weight 147 160 173 190 kg ...

Page 20: ...e of the fuel specified for the boiler according to the standards o The closed expansion tank of the system should be of the necessary size and pre tensioning pressure so it can compensate the changes in pressure of the system due to the change in temperature o The output of the heating circulation pump as well as the place and direction of installation should satisfy the new requirements o The hy...

Page 21: ... B AP PV GHISS B AE PV GHISS B 16 GHISS B16 PV GHISS B 24 GHISS B24 PV GHISS B 32 GHISS B32 PV GHISS B 40 1 forward 1 Ø 2 return 1 Ø 3 gas Ø 4 cold water for use Ø 5 hot water for use Ø 6 circulation Ø A 240 315 390 465 mm B 240 202 5 165 127 5 mm C 188 150 5 113 75 5 mm D 155 117 5 80 42 5 mm The selection of the type best fitting the heating system of the building is the task of the designer If ...

Page 22: ...are located within the appliance box Access can be achieved in the following way o Lift off the top of the boiler which is fixed by snaps o Screw out the screws of the top of the appliance box now you have access to the connecting hooks There is 230 V 50 Hz voltage present on the connectors of the device therefore in order to avoid accidents before you remove the top of the appliance box turn off ...

Page 23: ...ted for and what is at disposal upon connection o Check the cleanness of the gas pipe and if necessary install a filter in front of the boiler The gas connection must ensure gas of the appropriate quantity and pressure and the appropriate operation of the measuring and safety system must be checked After you have connected the device to the gas system check whether the seal is intact and whether t...

Page 24: ...AND DRAINING THE SYSTEM With the GHISS R AP and GHISS R AE type devices the filling up of the system can be executed through the filling up draining tap on the boiler With the GHISS R AP PV and GHISS R AE PV types if the device has been connected to the water system filling up can be performed through the filling up tap located on the device or through the filling up draining tap With the GHISS B ...

Page 25: ...g with the GHISS B type the boiler performs only the production of hot water for use while in the case of the GHISS R type if the indirect container and the necessary electronic unit are connected In other cases the device does not work in the summer position o Set the boiler regulating thermostat at the desired temperature o Turn on the main switch of the boiler the green light must be on While c...

Page 26: ...appen that during continuous operation the boiler stops and the error indicator lamp lights up For re establishment do the following o Take off the door of the boiler fastened by snaps o There are two protective hexagon plastic caps at the bottom of the appliance box Twist them off and under each of them is a press button The one on the left is the smoke gas restricting the one on the right is the...

Page 27: ...ng it on and off o The operation of the boiler thermostat by turning it off and on o The operation of the room thermostat by turning it off and on o The operation of the pump o The operation of the external separator by turning it off and on o If everything is operating perfectly the checking of the draught of the chimney and heating technical calibration follows ...

Page 28: ... drain the water from the heating and the hot water for use systems MAINTENANCE Based on the standards and regulations gas devices require regular maintenance and periodical check ups This increases the operational safety of the device and with the maintenance we can secure that the device always operates with the best degree of efficiency thus we can achieve the most optimal gas consumption Befor...

Page 29: ... 17 25 9 17 17 37 14 17 29 5 14 17 29 5 14 17 29 5 Number of nozzles pcs 2 3 4 5 6 7 Nozzle size Ø mm 2 35 1 45 1 45 2 35 1 45 1 45 2 35 1 6 1 6 2 35 1 6 1 6 2 45 1 6 1 6 2 45 1 6 1 6 Nozzle pressure mbar 12 8 21 4 25 9 12 5 21 4 27 11 6 16 5 22 12 0 17 2 24 1 11 5 19 5 24 5 11 5 18 6 24 Gas consumption m3 h 1 6 0 49 0 65 2 54 0 74 0 98 3 33 0 97 1 28 4 28 1 25 1 65 5 13 1 5 1 98 6 13 1 8 2 37 The...

Page 30: ...e measuring stub A o Start the boiler in the manner introduced earlier o Remove closing valve number 1 of the gas valve o With the help of bolt number 2 set the pressure value to the value specified in the table the bolt under the closing bolt By turning the bolt to the right pressure increases by turning it into the opposite direction it decreases o Remove the measuring device and put back the cl...

Page 31: ...aned and the inside surface of the cast heat exchanger becomes accessible o Check the cleanness of the surfaces of the heat exchanger and clean it if soot settlement is visible If the layer of soil is too thick you can use commercially available soot removing chemicals o Assembly logically is the reverse of the steps of disassembly The cleaning of GHISS B type boilers Attention Upon any maintenanc...

Page 32: ...k the condition of the anode rod and the washer ring if need be replace 9 Check the condition of the boiler filling up pipe manually clean it mechanically during the course of self feed rinsing 3 Remove the sediment with the help of the water jet applied through the cleaning hole through the draining tap of the boiler After cleaning mount the fittings in reverse order onto the structure of the boi...

Page 33: ...33 SERVICE INSTRUCTIONS 1 VERSION GB ...