OPERATING MANUAL

AC POWER DISTRIBUTION PANEL

DPAC1UT-AB-I-2-590

www.unipowerco.com

Manual No. DPAC1U-590-2

© 2016 UNIPOWER LLC

All Rights Reserved

dpac1ut_ab_i_2_590-man-rev2-0516.indd

NORTH AMERICA • 3900 Coral Ridge Drive, Coral Springs, Florida 33065, USA • Tel: +1 954-346-2442 • Fax: +1 954-340-7901 • sales-northamerica@unipowerco.com

EUROPE • Parkland Business Centre, Chartwell Road, Lancing  BN15 8UE,  ENGLAND  • Tel: +44(0)1903 768200 • Fax: +44(0)1903 764540  • sales-europe@unipowerco.com

Summary of Contents for DPAC1UT-AB-I-2-590

Page 1: ...ts Reserved dpac1ut_ab_i_2_590 man rev2 0516 indd NORTH AMERICA 3900 Coral Ridge Drive Coral Springs Florida 33065 USA Tel 1 954 346 2442 Fax 1 954 340 7901 sales northamerica unipowerco com EUROPE Pa...

Page 2: ...man rev2 0516 indd FIGURES Figure 1 Front View 4 Figure 2 Rear View 4 Figure 3 Internal Wiring 5 Figure 4 External Wiring of 5 Contents 1 0 DESCRIPTION 4 2 0 SAFETY WARNINGS 6 3 0 WARRANTY summary 6 4...

Page 3: ...ack space and can be mounted in either a 19 or 23 inch relay rack with corresponding brackets It can be mounted from the front of the rack with offsets every inch from front to back to align with exis...

Page 4: ...with a single 10 position terminal block on each side A and B see Figure 3 below Figure 3 Rear View 1 5 Figure 4 below is a schematic for the internal wiring while figure 5 is for the external wiring...

Page 5: ...ide are marked G N L1 L2 and are supplied by a single phase 120 240VAC source The input current rating is 25Afor each side N L1 L2 terminals of the A side are paralleled with the B side as shown in th...

Page 6: ...h the maximum specified ambient temperature 2 5 Reduced Air Flow Installation of these panels in a rack should be such that the amount of air flow required for safe operation is not compromised 2 6 Me...

Page 7: ...Nominal SAFETY CERTIFICATIONS UL60950 1 2nd Ed CSA22 2 No 60950 1 2nd Ed EN60950 1 2nd Ed ENVIRONMENTAL Operating Temp Range 0 C to 50 C Storage Temp Range 40 C to 85 C Humidity 0 to 95 Non Condensin...

Page 8: ...thout proper packing 6 0 INSTALLATION 6 1 Mounting This distribution panel can be mounted in either 19 or 23 inch racks by using the appropriate brackets Mount it from the front of the rack using the...

Page 9: ...7 3 Turn on the input power source Check the AC output voltage from L1 and L2 to N at each set of output terminals loads with a digital AC voltmeter The voltage should be approximately 120VAC 7 4 On...