background image

~ 1 ~ 

1. It's  available  for  indoor  use,  if  using  outdoors,  must  be  protected  by  waterproof

canopy. 

2. Choose  the  smooth  and  stable  installation  place,  don't  touch  the  detector  during

security checking to avoid false alarm. 

3. Make sure there's no big metal object or strong magnetic field around the detector

within 1~2 meters. 

4. Detector probe mustn't install in high temperature or wet circumstance.

5. Please wait 1 minute for its self-diagnosing when machine starts.

6. Do not disassemble the control units except for the professional technician.

7.

Follow  the  user  manual  carefully  and  make  sure  the  right  wire  connection  before

starting. 

   

 

  Please  read  carefully  the  following  considerations  to  avoid  the 

potential damage during installation. 

   

Summary of Contents for UB800

Page 1: ... magnetic field around the detector within 1 2 meters 4 Detector probe mustn t install in high temperature or wet circumstance 5 Please wait 1 minute for its self diagnosing when machine starts 6 Do not disassemble the control units except for the professional technician 7 Follow the user manual carefully and make sure the right wire connection before starting Please read carefully the following c...

Page 2: ... When the passengers carry metal content over preset parameters value the detector will automatically alarm meanwhile side LED lights will accurately indicate the alarm location It greatly helps security guards faster and easier to find out the prohibited metal objects such as guns knives keys etc ...

Page 3: ... etc 2 Movable Metallic Items Installation near movable items it should stay away from the detector at least 0 5 2 meters to avoid false alarm Especially install the detector at factory gate or ground floor Pls pay attention to the effect of rolling gate iron walk through metal detectors elevators and cars on the detector 3 Vibration effection The installation ground should be flat and fixed to pr...

Page 4: ...rces are as follows Electrical Control Box Radio Equipment Interphone Electronic Computer And Peripheral Equipment Video Monitor High Power Motor Power Transformer Ac Power Lines Thyristor Control Circuit High Power Switching Power Supply Inverter Welder Engine Motor etc 5 Tips for working in line When installing the detectors in line the distance between two walk through metal detectors cannot be...

Page 5: ...nterference capability 100 frequencies for option To work with neighbouring gates at 40cm Alarm volume range from level 1 to 9 Alarm tones Change from 0 to 9 10 different tones for choosing Detecting speed up to 100 passenger min Anti interference function using advanced interactive transmitting and receiving to avoid interference Password Protection The sensitivity and programing parameters can o...

Page 6: ... 6 PARTS 1 Main Control Unit 2 Side LED indicator 3 Side door frame panel 4 Infrared Sensor 5 Waterproof Foot Cover 6 Power supply socket 2 4 5 6 3 1 ...

Page 7: ...r panel 2 Put the control unit case and door panels as above picture shown then connect the left and right door panel with the control unit case by bolts and nuts Tighening screws 3 Probe line of the left and right door panel tight inserted into the motherboard corresponding socket respectively ...

Page 8: ...ntrol unit case cover 5 Lift the walk through metal detector to the vertical position and move to the assigned position 6 Plug power cable CONTROL PANEL There are six buttons on the operation panel 1 LEFT Turn left 2 RIGHT Turn right ...

Page 9: ...onfirm 6 POWER Turn on off 7 Infrared Remote Control 8 7 inch color LCD screen Remote control Turn ON OFF Can turn on off detector quickly Back to normal working status PASS CTN ALARM CTN Confirm Enter Save menu back Turn upward and number increase Turn downward and number decrease Turn left ...

Page 10: ... numbers to change the parameters directly NORMAL WORKING STATUS 1 Into the self checking interface After powered on the walk through metal detector automatically enter into self checking interface 2 LCD screen normal working status as below ...

Page 11: ...rface the up key increase the number the down key reduce the number right key let the cursor turn right Initial password 000000 3 Press the Enter key to enter the menu interface the up down left and right keys to select the menu item Press Enter key to open the submenu press the power button to exit the menu ...

Page 12: ...p and down keys to select the location to enter the single zone self learning mode If for manual adjusting parameters press the left or right button to select the current area digit to ones digit tens digit hundreds digit The up and down key to adjust the digit 0 9 the sensitivity 0 999 total 1000 sensitivity can be adjusted left and right adjust to ten digit or hundred digit Press Enter key to sa...

Page 13: ...previous menu 7 Frequency According to the site requirements on the walk through metal detector operating frequency required use the left and right key to select the operating frequency of automatic adjusting or manually adjust to set the working frequency band Press Enter key to enter the submenu Press power key to return to the previous menu ...

Page 14: ...us menu Note After the Working frequency automatically opened the walk though metal detector will automatically check the magnetic field around and choose the best frequency to adapt to the current environment every time so the boot time will be extended After finished adjusted can turn off automatic opening working frequency function ...

Page 15: ...to increased as 10 digit the up and down keys increased as 1 digit the Enter key to save and return to the previous menu 10 Alarm Set The Ring setting LED setting Zone setting as below Left right key to select the item Press Enter key to enter the submenu press power key to return to the previous menu ...

Page 16: ...and down key to adjust parameters Press Enter key to save the data and return to the previous menu 12 LED setting LED lights up time 0 9 adjustable up and down key to adjust the numbers Press Enter key to save and return to the previous menu 13 Zone setting can be divided into 6 12 18 zones and 33 zones Left right key to select the item Press Enter key to save and return to the previous menu ...

Page 17: ...e date and time parameters left and right key to increase reduce the numbers of Date Press Enter key to save and return to the previous menu 15 Language Set the language Left Right key to select the language Note Currently only English language option If need customize other languages pls contact us ...

Page 18: ... directly return to the previous menu 17 Alarm query Up and down key to adjust date month year value left and right keys to select the adjusting items 0 shows the alarm record of that date Press Enter key to enter the alarm recording interface the data display content for the alarm location strength and LED lights 18 More Brightness Signal out situation Device Info Left right key to select the ite...

Page 19: ...19 Brightness Screen brightness setting Left and right to adjust the brightness Press Enter key to save and return to the previous menu 20 Signal out left and right key to select the item Press Enter key to save and return to the previous menu ...

Page 20: ...ferent options Up Down Left Right Select the item Press Enter key to save and return to the previous menu 22 Device Info View the software version and ID press the Enter key or the power button to return to the previous menu ...

Page 21: ...enu For Public Security Bureau large scale activities etc on site security checking 3 For low sensitivity requirements can set whole sensitivity to low For the locations which requires low sensitivity only detecting big metals 4 Automatically frequency usually off after installed and finished commissioning to save the boot time for environmental inspection when powered on PACKING LIST Package shou...

Page 22: ...0 240V 50 60Hz Power 30W Gross weight 65KG Package 2 cartons Working temperature 30 70 Sensitivity 0 999 adjustable Alarm Visible and audible alarm Inner Dimensions 1990mm H x 700mm W x 500mm D External Dimensions 2230mm H x 835mm W x 580mm D ...