background image

 

© 2016 unitech Electronics Co., Ltd. All rights reserved.   

unitech is a registered trademark of unitech Electronics Co., Ltd

 

 

          

BT CCD Scanner

     

 

 

 

 

 

 

 

 

                                                                                  

FCC ID: HLEMS340BT

 - 

 

 

 

 

 

Us

Us

er's Manual

Version 1.1 

 

Summary of Contents for MS340BT

Page 1: ... 2016 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd BT CCD Scanner FCC ID HLEMS340BT sUser s Manual Version 1 1 ...

Page 2: ...nics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd Change Log Date Change Description Version 2016 1 11 first published version 1 0 2016 1 22 Add 1 4 2 Installing the battery 1 1 ...

Page 3: ...he FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference with radio communications However there is no guarantee that interference will not occur in a particula...

Page 4: ...ority to operate the equipment FCC Label Statement This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Canadian Compliance Statement This Class B Digital apparatus meets all requirement...

Page 5: ...ch eu public Safetyregulatorystatement RoHS Statement This device conforms to RoHS Restriction of Hazardous Substances European Union regulations that set maximum concentration limits on hazardous materials used in electrical and electronic equipment Waste electrical and electronic equipment WEEE unitech has set up a policy and process to meet the EU directive 2002 96 EC and update 2003 108 EC con...

Page 6: ...ch Electronics Co Ltd Taiwan NCC Warning Statement 交通部電信總局低功率電波輻射性電機管理辦法 第十二條 經型式認證合格之低功率射頻電機 非經許可 公司 商號或使用者 均不得擅自變更頻率 加大功率或變更原設計之特性及功能 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信 經發現有 干擾現象時 應立即停用 並改善至無干擾時方得繼續使用 低功率射頻電機需忍受合法通信或工業 科學及醫療用電波輻射性電機設備 之干擾 注意事項 1 使用過度恐傷害視力 2 使用30分鐘請休息10分鐘 2歲以下幼兒不看螢幕 2歲以上每天看螢幕不要超過 1小時 ...

Page 7: ...vice operations The laser safety warning label required by the DHHS IEC for the unitech product s optional laser scanner module is located on the memory compartment cover on the back of the unit Laser information only applies to the products with laser components CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser ligh...

Page 8: ...er than a fully uncharged battery Charging a partially charged battery does not cause harm to the unit Keep the battery cool Avoid hot vehicles For prolonged storage keep the battery at a 40 charge level Do not leave the battery uncharged and unused for an extended period of time the battery will wear out and the longevity of the battery will be at least half of one with frequent charges 4 Protect...

Page 9: ...us Please use a battery temperature detecting device for a charger to ensure a safe charging temperature range Storage and safety notice Although charged batteries may be left unused for several months their capacity may be depleted due to build up of internal resistance If this happens they will require recharging prior to use Batteries may be stored at temperatures between 20 C to 60 C however t...

Page 10: ...same specification of adapter to charge your unitech product Using the wrong power adapter can damage your unitech product The message above only applies to the product connected to the adapter For the products without using the adapters please refer to the specification of each product Hearing Damage Warning Zx 3 Warning The warning shall be placed on the equipment or on the packaging or in the i...

Page 11: ...9 5015 BB Tilburg the Netherlands http eu ute com China Japan Tel 86 59 2310 9966 Tel 81 3 35232766 E mail info cn ute com E mail info jp ute com Address Website Room401C 4F RIHUA International Mansion Xinfeng 3nd Road Huoju Hi tech District Xiamen Fujan China http cn ute com Address Website Kayabacho Nagaoka Building 8F 1 5 19 Shinkawa Chuo Ku Tokyo 104 0033 Japan http jp ute com Asia Pacific Mid...

Page 12: ...nty are free from defects during normal use The warranty period is varied from each country Please consult with your supplier or unitech local office for actual length of warranty period to your purchased product Warranty becomes void if equipment is modified improperly installed or used damaged by accident or neglect or if any parts are improperly installed or replaced by the user ...

Page 13: ...anner Cradle Detail 2 1 3 Specifications 3 1 4 Getting Started 6 1 5 Battery Charging 10 1 6 LED Indicator Beeper Sequence 11 Chapter 2 Configuration General 13 2 1 Flow Chart 13 2 2 Loop of Programming 14 2 3 Factory Default Settings 14 2 4 Main Page of Configuration 15 Chapter 3 Bar Codes Others 16 3 1 SymboIogies Selection 16 3 2 UPC EAN JAN Parameters 18 3 3 Code 39 Parameters 20 3 4 Code 128 ...

Page 14: ...de ID 34 Chapter 4 Command Setting 37 4 1 Interface Reading Mode Selection 37 4 2 Communication Parameters 39 4 3 Language Selection 42 4 4 Reading Level 43 4 5 Accuracy 44 4 6 Buzzer Beep Tone 44 4 7 Sensitivity of Continuous Reading Mode 45 4 8 Reverse Output Characters 46 4 9 Setup Deletion 46 4 10 Setup Insertion 49 4 11 PAN Configuration 52 Appendix A Numeric Bar Codes 55 Appendix B ASCII Tab...

Page 15: ...lease make sure the following contents are in the MS340B gift box If something is missing or damaged please contact your unitech representative The standard package contents MS340B Scanner Quick Start Guide Regulatory Compliance Statements Cable Cradle Adapter Note To scan a barcode make sure the aiming beam crosses every bar and space of the barcode ...

Page 16: ... Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd 1 2 Scanner Cradle Detail Scan Window Trigger Cable connector Scanner LED indicator Cradle LED indicator Cradle ...

Page 17: ...SB Light Source 635 nm Visible Red LED Max Resolution 4mil 0 1mm PCS90 Code39 Scan Rate Up to 500 scans second Skew Angle 60 5 Pitch Angle 10 65 5 Printing Contrast Scale minimum 30 Decoding Supports most standard 1D bar code GS1 Databar linear and stacked Codes Depth of Field DOF Code39 PCS 90 Communication Radio Frequency Bluetooth V2 1 EDR smaller 10mW Frequency Band 2 402GHz 2 480 GHz Transmis...

Page 18: ...0 times Electrical Input Voltage 5VDC Operating Power 200mA Standby Power 60mA Battery Li ion 3 7V 2600 mAh Charging time Approx 5 hours Reads per charge 50 000 times Environmental Light Levels Max 100 000 Lux Mechanical Shock 1 5m onto concrete scanner only IP Rate IP42 Operating Temperature 0 C to 50 C Storage Temperature 20 C to 70 C Relative Humidity 20 to 95 non condensing Regulation Approval...

Page 19: ...5 2016 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd Readable Symbologies ...

Page 20: ...e BT MAC address code located on the bottom of the cradle 3 When the BT MAC address code was successfully scanned scanner will sound 3 short beeps with green LED flash once 4 Wait approximately five seconds for completing the connection process with up tone 5 If successful blue LED of scanner will slow flash and the cradle will be continued on B Setup SPP Slave Mode SPP Slave Mode Please follow th...

Page 21: ...etooth HID profile application device 1 The scanner must scan HID Slave Mode barcode to set the scanner in HID slave mode 2 When control the BT device to search the scanner enter pin code default 00 00 00 to setup pairing You can scan number barcode on Appendix D Numeric Bar Codes 2 number 0 9 to setup 3 When scanner is successful connected scanner blue LED will also blink with up tone Blue LED wi...

Page 22: ...scanner battery please follow the instructions below 1 Use screwdriver to loosen the screw on the bottom of the scanner and remove the battery cover 2 Slide and position the battery make sure the battery contacts are aligned with the contacts in the scanner 3 Replace the battery cover and use the screwdriver to tighten the screw on the bottom of the scanner ...

Page 23: ... from the cradle it is recommended that the power on the host system is off and the power supply has been disconnected from the unit 1 Find the small Pin hole on the bottom of the cradle Please see the photo as below 2 Use a bended regular paperclip and insert the tip into the hole 3 You will hear a click then gently pull out the strain relief of the cable Pin hole ...

Page 24: ...ge and use the MS340B for the first time you will need to fully charge the battery It takes approximately 5 hours to fully charge the battery To chage the scanner with a cradle please follow the instructions below 1 Plug the adapter cable into the power socket on the bottom of cradle 2 Plug the AC adapter cord into an electrical outlet 3 Place the scanner in the cradle The scanner LED will be red ...

Page 25: ...Transmit Fail Green light blinks twice Two beeps Battery fully charged Solid green light No action Memory full Red light blinks twice Two beeps Low Battery warning Red light blinks once every 20 seconds One beep In charging Solid red light No action BT disconnect Blue light blinks twice continuously No action BT disconnect before sleep No action Low beep BT connected Blue light blinks once every t...

Page 26: ...ech is a registered trademark of unitech Electronics Co Ltd Cradle LED Status Action Status LED for Barcode reading Communication Good read and transmitted Green light blinks once BT disconnect continuously Blue light blinks twice BT connected Solid blue light ...

Page 27: ... reserved unitech is a registered trademark of unitech Electronics Co Ltd Chapter 2 Configuration General 2 1 Flow Chart Please scan the following barcodes for configuration Start Configuration End Configuration Abort Configuration Save Parameters ...

Page 28: ...ll Defaults Please refer to 2 4 Main Page of Configuration 2 3 Factory Default Settings The barcode with an asterisk which appears in the following chapters indicates that it is the default option for the corresponding setting The barcode with two asterisks indicate that it is the quick setting label You can make your own settings by following the procedures in this manual If you want to save the ...

Page 29: ...onfiguration Abort Configuration Version Information Quick Setting Label Save Parameters The parameter settings will be saved permanently Recall Stored Parameters Replace the current parameters by the parameters you saved last time Set AII Defaults Set all the parameters to the factory default settings Abort Configuration Terminate current programming status Version Information Display the decoder...

Page 30: ...rial 25 OFF UPC E ON UPC E OFF Matrix 25 ON Matrix 25 OFF EAN 13 JAN 13 ISBN 13 ON EAN 13 JAN 13 ISBN 13 OFF CODE 93 ON CODE 93 OFF EAN 8 JAN 8 ON EAN 8 JAN 8 OFF CODE 11 ON CODE 11 OFF CODE 39 ON CODE 39 OFF China Postage ON China Postage OFF CODE 128 ON CODE 128 OFF MSI PLESSEY ON MSI PLESSEY OFF CODABAR NW7 ON CODABAR NW7 OFF Code 2 of 6 ON Code 2 of 6 OFF Interleave 25 ON Interleave 25 OFF LCD...

Page 31: ...k of unitech Electronics Co Ltd Telepen ON Telepen OFF GS1 DataBar Omnidirectional ON GS1 DataBar Omnidirectional OFF Reserved5 ON Reserved5 OFF GS1 DataBar Limited ON GS1 DataBar Limited OFF Reserved6 ON Reserved6 OFF GS1 DataBar Expanded ON GS1 DataBar Expanded OFF Select All Bar Codes ...

Page 32: ...Reading Type B Supplemental Set Up UPCA EAN13 ON UPCA EAN13 OFF Not Transmit ISBN 10 Enable ISBN 13 Enable Transmit 2 Code ISSN Enable ISSN Disable Transmit 5 Code Decode with Supplement Auto discriminate Supplement Transmit 2 5 Code Expand UPC E Enable Expand UPC E Disable EAN8 EAN13 Enable EAN8 EAN13 Disable GTIN Format Enable GTIN Format Disable ...

Page 33: ...on UPC A Check Digit Transmission ON UPC A Check Digit Transmission OFF UPC E Check Digit Transmission ON UPC E Check Digit Transmission OFF EAN 8 Check DigitTransmission ON EAN 8 Check DigitTransmission OFF EAN 13 Check Digit Transmission ON EAN 13 Check Digit Transmission OFF ISSN Check Digit Transmission ON ISSN Check Digit Transmission OFF ...

Page 34: ... Digit Transmit Enable Enable Standard Calculate Check Digit Not Transmit Full ASCII E Set Up Code Length To set the fixed length 1 Scan the Begin label of the desired set 2 Go to Numeric Bar Codes in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set Repeat the steps 1 3 to set additional lengths Variable Fix Length 2 Sets Available 1 1st Se...

Page 35: ...smit ON Enable Code128 Group Separators GS Disable Code128 Group Separators GS Do Not Calculate Check Digit D Set Up Code Length To set the fixed length 1 Scan the Begin label of the desired set 2 Go to Numeric Bar Codes in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set Repeat the steps 1 3 to set additional lengths Variable Fix Length 2 ...

Page 36: ...eck Digit Not Transmit D Set Up Code Length To set the fixed length 1 Scan the Begin label of the desired set 2 Go to Numeric Bar Codes in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set Repeat the steps 1 3 to set additional lengths Variable Fix Length 2 Sets Available 1 1st Set Begin 3 1st Set Complete 1 2nd Set Begin 3 2nd Set Complete ...

Page 37: ...nsmit C Set Up Code Length To set the fixed length 1 Scan the Begin label of the desired set 2 Go to Numeric Bar Codes in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set Repeat the steps 1 3 to set additional lengths Variable Fix Length 2 Sets Available 1 1st Set Begin 3 1st Set Complete 1 2nd Set Begin 3 2nd Set Complete Minimum Length 1 ...

Page 38: ...th To set the fixed length 1 Scan the Begin label of the desired set 2 Go to Numeric Bar Codes in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set Repeat the steps 1 3 to set additional lengths Variable Fix Length 2 Sets Available 1 1ST Set Begin 3 1ST Set Complete 1 2nd Set Begin 3 2nd Set Complete Minimum Length 1 Begin 3 Complete 2 Numer...

Page 39: ...ch is a registered trademark of unitech Electronics Co Ltd 3 8 CODABAR NW7 Parameters A Set Up Start Stop Characters Upon Transmission B Transmission Type of Start Stop OFF A B C D Start A B C D Stop ON A Start A Stop B Start B Stop C Start C Stop D Start D Stop ...

Page 40: ...Go to Numeric Bar Codes in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set Repeat the steps 1 3 to set additional lengths Variable Fix Length 2 Sets Available 1 1st Set Begin 3 1st Set Complete 1 2nd Set Begin 3 2nd Complete Minimum Length 1 Begin 3 Complete 2 Numeric Bar Codes Appendix A 2 Numeric Bar Codes Appendix A 2 Numeric Bar Codes ...

Page 41: ...ixed length 1 Scan the Begin label of the desired set 2 Go to Numeric Bar Codes in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set Repeat the steps 1 3 to set additional lengths Variable Fix Length 2 Sets Available 1 1st Set Begin 3 1st Set Complete 1 2nd Set Begin 3 2nd Set Complete Minimum Length 1 Begin 3 Complete 2 Numeric Bar Codes Ap...

Page 42: ...Digit Not Transmit B Set Up Code Length To set the fixed length 1 Scan the Begin label of the desired set 2 Go to Numeric Bar Codes in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set Repeat the steps 1 3 to set additional lengths Variable Fix Length 2 Sets Available 1 1st Set Begin 3 1st Set Complete 1 2nd Set Begin 3 2nd Set Complete Mini...

Page 43: ...Length To set the fixed length 1 Scan the Begin label of the desired set 2 Go to Numeric Bar Codes in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set Repeat the steps 1 3 to set additional lengths Variable Fix Length 2 Sets Available 1 1st Set Begin 3 1st Set Complete 1 2nd Set Begin 3 2nd Set Complete Minimum Length 1 Begin 3 Complete 2 N...

Page 44: ...ngth To set the fixed length 1 Scan the Begin label of the desired set 2 Go to Numeric Bar Codes in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set Repeat the steps 1 3 to set additional lengths Variable Fix Length 2 Sets Available 1 1st Set Begin 3 1st Set Complete 1 2nd Set Begin 3 2nd Set Complete Minimum Length 1 Begin 3 Complete 2 Num...

Page 45: ...h To set the fixed length 1 Scan the Begin label of the desired set 2 Go to Numeric Bar Codes in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set Repeat the steps 1 3 to set additional lengths Variable Fix Length 2 Sets Available 1 1st Set Begin 3 1st Set Complete 1 2nd Set Begin 3 2nd Set Complete Minimum Length 1 Begin 3 Complete 2 Numeri...

Page 46: ...Transmit C Set Up Code Length To set the fixed length 1 Scan the Begin label of the desired set 2 Go to Numeric Bar Codes in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set Repeat the steps 1 3 to set additional lengths Variable Fix Length 2 Sets Available 1 1st Set Begin 3 1ST Set Complete 1 2nd Set Begin 3 2nd Set Complete Minimum Length...

Page 47: ...meters Transmit Check Digit Don t Transmit Check Digit Transmit Check Digit Don t Transmit Check Digit Transmit Application ID Don t Transmit Application ID Transmit Application ID Don t Transmit Application ID Don t Transmit Symbology ID Transmit Symbology ID Don t Transmit Symbology ID Transmit Symbology ID C GS1 DataBar Expanded Parameters Don t Transmit Symbology ID Transmit Symbology ID ...

Page 48: ...user may refer to the following table to know what kind of bar code is being scanned Please refer to the table below for matching code ID of codes read in Code Type ID Code Type ID UPC A A UPC E B EAN 8 C EAN 13 D CODE 39 E CODE 128 F Interleave 25 G Industrial 25 H Matrix 25 I Codabar NW7 J CODE 93 K CODE 11 L China Postage M MSI PLESSEY N Code 2 of 6 P LCD 25 Q Telepen T GS1 DataBar Omnidirectio...

Page 49: ...ASCII Tables in Appendix B scan label that represents the desired code ID Note User define code ID will override default value Program will not check the conflict It is possible to have more than two symbologies which have same code ID UPC A UPC E EAN 13 JAN 13 EAN 8 JAN 8 CODE 39 CODE 128 CODABAR NW7 Interleave 25 Industrial 25 Matrix 25 CODE 93 CODE 11 ChinaPostage MSI PLESSEY Code 2 of 6 Telepe...

Page 50: ...itech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd LCD25 GS1 DataBar Omnidirectional ON GS1 DataBar Limited ON GS1 DataBar Expanded ON Reserved5 Reserved6 ...

Page 51: ... Electronics Co Ltd Chapter 4 Command Setting 4 1 Interface Reading Mode Selection 4 1 1 Cradle Interface Selection USB Mode RS232 Mode Virtual COM 4 1 2 Reading Mode Selection Trigger ON OFF Good Read OFF Continuous Trigger OFF Testing Continuous Auto Power On Flash Flash Auto Power On Presentation ...

Page 52: ... trademark of unitech Electronics Co Ltd 4 1 3 BT Auto Connection Enable Disable 4 1 4 iOS Hotkey Function When enabling iOS Hotkey you may simply double click the trigger to toggle the iPhone iPad Touch Keyboard Note This function is only available for iPhone iPad Enable Disable ...

Page 53: ... unitech is a registered trademark of unitech Electronics Co Ltd 4 2 Communication Parameters 4 2 1 RS232 Communication Parameters A Set Up BAUD Rate B Set Up Data Bits C Set Up Stop Bits 9600 8 Data Bits 1 Bit 1200 7 Data Bits 2 Bits 2400 4800 19200 38400 ...

Page 54: ...d All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd D Set Up Parity E Handshaking None RTS CTS Disable RTS CTS Enable Even ACK NAK Disable ACK NAK Enable Odd XON XOFF Disable XON XOFF Enable Mark Space ...

Page 55: ...s reserved unitech is a registered trademark of unitech Electronics Co Ltd 4 2 2 Output Characters Parameters A Select Terminator B Time out Between Characters CR 0 ms None 5 ms CR LF 10 ms LF 25 ms Space 50 ms HT TAB 100 ms STX ETX 200 ms 300 ms ...

Page 56: ...s reserved unitech is a registered trademark of unitech Electronics Co Ltd 4 3 Language Selection US English Hungarian UK English Janpanese Italian Belgium Spanish Portuguese French Denmark German Netherlands Swedish Turkey Switzerland Reserved 2 ...

Page 57: ...o Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd 4 4 Reading Level The Polarity can be sent as standard with black bars high or reversed with white bars high Black Bars High White Bars High ...

Page 58: ...he assurance of barcode consistency and to prevent the misread outcome before the data is sent to the host Scan the barcode below to choose how many times you would like to verify the data Note It will cause the scanning process to slow down by choosing more than 1 time to verify the data 1 Time 2 Times 3 Times 4 Times 4 6 Buzzer Beep Tone High Medium Low Off ...

Page 59: ... reading mode The value can be defined from 1 50 and they represent 100ms to 5 seconds in100ms interval Default value is 3 0 3 seconds To setup same code delay reading interval 1 Scan the Begin label 2 Go the Numeric Bar Codes in Appendix A Scan label s that represents the same code delay reading interval They are ranged form 1 50 One step is represented 0 1second So the interval is from 0 1 to 5 ...

Page 60: ...he desired symbology 3 Go to the Numeric Bar Codes in Appendix A scan label s that represents the desired position to be deleted 4 Scan the Complete label of Character Position to be Deleted 5 Go to the Numeric Bar Codes in Appendix A scan label s that represents the number of characters to be deleted 6 Scan the Complete label of Number of Characters to be Deleted Repeat the steps 1 6 to set addit...

Page 61: ...ctronics Co Ltd B Symbologies Selection UPC A Industrial 25 UPC E Matrix 25 EAN 13 JAN 13 ISBN 13 CODE 93 EAN 8 JAN 8 CODE 11 CODE 39 China Postage CODE 128 MSI PLESSEY CODABAR NW7 Code 2 of 6 Interleave 25 Telepen LCD25 GS1 DataBar Omnidirectional GS1 DataBar Limited GS1 DataBar Expanded None All Codes ...

Page 62: ...ll rights reserved unitech is a registered trademark of unitech Electronics Co Ltd C Character Position to be Deleted 2 Complete D Number of Characters to be Deleted 2 Complete 1 Numeric Bar Codes Appendix A 1 Numeric Bar Codes Appendix A ...

Page 63: ...n label s that represents the desired position to be inserted 4 Scan the Complete label of Character Position to be Inserted 5 Go to the ASCII Tables in Appendix B or Function Key Tables in Appendix C scan label s that represents the desired characters to be inserted Scan the Complete label of Number of Characters to be Deleted 6 Scan the Complete label of Characters to be inserted Repeat the step...

Page 64: ...ctronics Co Ltd B Symbologies Selection UPC A Industrial 25 UPC E Matrix 25 EAN 13 JAN 13 ISBN 13 CODE 93 EAN 8 JAN 8 CODE 11 CODE 39 China Postage CODE 128 MSI PLESSEY CODABAR NW7 Code 2 of 6 Interleave 25 Telepen LCD25 GS1 DataBar Omnidirectional GS1 DataBar Limited GS1 DataBar Expanded None All Codes ...

Page 65: ...o Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd C Character Position to be Inserted 2 Complete D Characters to be Inserted 2 Complete 1 ASCII Table Appendix B 1 Numeric Bar Codes Appendix A ...

Page 66: ...proximately 25 000 sets of EAN13 barcode type The all stored data will be transmitted to device when the link is reconnected and the all data stored in out of range memory will be cleared 4 11 2 Sleep Mode Sleep Mode OFF Sleep Mode 1 min ON Sleep Mode10 min ON The scanner is equipped with sleep mode function to save battery energy when the scanner is not used for 1 minute or 10 minutes During slee...

Page 67: ...gistered trademark of unitech Electronics Co Ltd 4 11 3 Batch Mode Batch Mode OFF Batch Mode ON Delete Last Data Batch Data Read Batch Data Clear Quick Setting Label The function can be executed directly by scanning barcode instead of doing the general programming process ...

Page 68: ...ech is a registered trademark of unitech Electronics Co Ltd 4 11 4 Firmware Version Scanner Firmware Version Cradle Firmware Version Scanner MAC Address Cradle MAC Address Quick Setting Label Display the firmware version of the scanner please scan above barcode ...

Page 69: ...55 2016 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd Appendix A Numeric Bar Codes ...

Page 70: ...56 2016 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd Appendix B ASCII Table ...

Page 71: ...57 2016 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd ...

Page 72: ...58 2016 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd ...

Page 73: ...59 2016 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd ...

Page 74: ...60 2016 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd Appendix C Function Key Table ...

Page 75: ...61 2016 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd Appendix D Numeric Bar Codes2 ...

Reviews: