background image

A Versatile Multi-Function Terminal

User Manual

Talk

Mic

400664G Version 3.0

Summary of Contents for TASHI MT180

Page 1: ...A Versatile Multi Function Terminal User Manual Talk Mic 400664G Version 3 0...

Page 2: ......

Page 3: ...h adc com Regulatory Compliance Statements FCC Statement This is a FCC Part 15 Class A product In a domestic environment this product may cause radio interference in which case the user may be require...

Page 4: ...i Warranty Under Unitech limited Warranty the following items are covered MT180 IP based Access Control Terminal is covered by one year limited warranty Cables are covered by one year limited warranty...

Page 5: ...ing Software 4 Chapter 2 Using the Hardware 5 Using the Keypad 5 Using Proximity Reader 6 Using Fingerprint Reader 8 Using DECT Phone Optional 11 Chapter 3 On Screen Setting 12 General Settings 12 Adv...

Page 6: ...iv Worldwide Support 46...

Page 7: ...nce management in your daily life Features Powerful system ARM7TDMI S processor with speeds up to 72 MHz System memory 8MB external flash Display COG FSTN LCD with white backlight 128 64 pixel resolut...

Page 8: ...TE MT180 comes with an anti theft sensor inside the rear panel If you want to set up MT180 before installation do one of the following to disable the alarm buzzer 1 Attach a magnet behind the sensor o...

Page 9: ...network 2 As the default IP address of MT180 is set to be 192 168 2 127 you have to set your computer to be on the same subnet with MT180 For example IP Address 192 168 2 100 Network Mask 255 255 255...

Page 10: ...de area of TASHI network Refer to the comparison table below to find the best way working out your setup If you find necessary to get MTTool please contact regional sales representatives or technical...

Page 11: ...ompt to input 2 digit group number and 4 digit group access password to open door In Access Attendance Mode you can press F2 or F3 button to switch to Attendance Mode then press F2 F3 button to choose...

Page 12: ...Swipe your card on the Proximity Reader The terminal beeps three times The screen displays Invalid Card with your card number 5 In MTTool under the SysSet2 tab input the card number user name group n...

Page 13: ...r a user name DEMOUSER for example Click in the field of CardNo The Card Setting window appears NOTE Make sure your card type is compatible with the reader 6 Follow MT180 on screen instructions to ent...

Page 14: ...adjust your finger place according to on screen prompts The screen may remind you that the finger is too high too low too left too right too small no finger or remove finger and put finger repeatedly...

Page 15: ...the Index field and click Enroll Finger button 1 Then input 000000000000 in the Fingerprint Index field and click Add a Card No button 2 Follow instructions below to utilize JanitorLite to collect fin...

Page 16: ...the IP address and port number of the fingerprint reader Click OK 5 Click User User Management Double click the created DEMOUSER The User Setting window appears Click Fingerprint button The Fingerprin...

Page 17: ...ton MT180 con nects to your DECT phone while the screen displays Connect Please wait The LED indicator on DECT phone flashes and the phone rings with the HS number for MT180 HS1 by default shown on th...

Page 18: ...ut you finger on the fingerprint reader Each card allows to enroll a maximum of three fingerprints Enter the Modify Card PIN option Follow the on screen prompt to swipe your card The screen dis plays...

Page 19: ...an switch the terminal language Current languages supported are English Simplified Chinese and Traditional Chinese Enter the Set Backlight option You can set the backlight behavior Select Always turn...

Page 20: ...er the Reboot option Select Yes to reboot the system The screen displays Device reboot Please wait and the system reboots itself Select No to go back to Advanced options Enter the Resume Default optio...

Page 21: ...ow instructions below to utilize MTTool to manage time and attendance 1 Set MT180 and your computer on the same subnet network 2 Execute MTTool on your computer 3 Under SysSet1 tab in MTTool select Wi...

Page 22: ...istered trademark of Unitech Electronics Co Ltd 4 Click Adjust to synchronize the system time with your computer 5 Click Get to double check the date and time set on the terminal 6 In the Terminal Set...

Page 23: ...field under SysSet2 tab check a desired shift On Morning for example Click Set 8 In the Card Setting field input the card number user name user number group number etc Click Add a Card No NOTE See Gen...

Page 24: ...ctronics Co Ltd 9 Under WeeklySchedule tab select Weekly Attendance Schedule 10 Double click on a desired table cell in a desired shift row row On Morning Shift Duty in this case The Period Code windo...

Page 25: ...shift in other weekdays The period codes 7F in this case display on the shift row Click Set 13 Under GroupSet tab select the desired group 0 in this case 14 Double click on a desired table cell row 1...

Page 26: ...case displays on the table cell 16 Select None in the field of Attendance Mode Setting 17 Click Set Group Info Follow instructions below to utilize JanitorLite to manage time and attendance 1 Set MT1...

Page 27: ...ler 192 168 110 230 for example in the IPHost field Click Apply 9 Click the Reset button to reset data in this controller set by MTTool if any A pop up window appears asking if you want to reset Click...

Page 28: ...name Demo for example Click Apply and then OK to return to the User Group Setting window 14 Right click the desired group Demo in this case and click Append Entity to add a new user The User Setting w...

Page 29: ...quire your card number 18 Click OK to return to the User Group Setting window 19 Click Permit Permit Management 20 Select the desired user group Demo in this case and click Setting on the toolbar The...

Page 30: ...ab select a desired shift On Morning for example 24 Under Shift Info tab select a desired weekday Thursday for example 25 Double click inside the field of PeriodID The period selection window appears...

Page 31: ...to Clock In While the standby screen on MT180 displays the desired shift name morn ing shift work in this case swipe your card on the Proximity Reader The user name TAttendance in this case and clock...

Page 32: ...user controller and date and click OK You can find the attendance record displays under the Preview tab Security Operation MT180 allows you to set up a secure area enclosed by the terminal and surroun...

Page 33: ...security ban by the same proximity card used in access control or time attendance mode Follow instructions below to utilize MTTool to optimize your security settings 1 Connect Pin 4 CHECK to Pin 9 GN...

Page 34: ...Co Ltd 5 Under SysSet1 tab in MTTool select WinSocket and input the IP address 192 168 110 230 for example Click Connect NOTE See Advanced Settings on page 13 to set the IP address on MT180 6 Click A...

Page 35: ...29 8 In the Set1 field select Buzzer from the drop down menu of System Alarm Notification Click Set 9 In the Card Setting field under SysSet2 tab input the card number user name user number group numb...

Page 36: ...rk of Unitech Electronics Co Ltd 10 Under WeeklySchedule tab select Weekly Security Schedule 11 Double click on a desired table cell row 1 column Thursday for example The Period Code win dow appears 1...

Page 37: ...e period code 7F in this case displays on the table cell Click Set 14 Under GroupSet tab select the desired group 0 in this case 15 Double click on a desired table cell row 1 column Thursday in this c...

Page 38: ...d time 00002359 for example to set for 24 hours in this weekday Click OK The period code 7F in this case displays on the table cell 17 Select Enable Disable Security Mode in the field of Security Mode...

Page 39: ...y screen indicating security ban has been put Scenario II Lift Security Ban While in standby status with message Secured Status press button to enter the security set ting screen Current security stat...

Page 40: ...ssage SecuredAlarm disappears on the standby screen Check the loop and reconnect Pin 5 SAFE to Pin 10 GND Anti Pass Back Setting You can enforce Anti Pass Back to control the entrance exit behavior an...

Page 41: ...cket and input the IP address 192 168 110 230 for example Click Connect NOTE See Advanced Settings on page 13 to set the IP address on MT180 5 Click Adjust to synchronize the system time with your com...

Page 42: ...registered trademark of Unitech Electronics Co Ltd 7 In the Terminal Setting field select Internal External from the drop down menu of Reader Click Set 8 In the Card Setting field under SysSet2 tab in...

Page 43: ...this case 10 Double click on a desired table cell row 1 column Thursday in this case The Period Code win dow appears 11 Click a desired period time 00002359 for example to set for 24 hours access in...

Page 44: ...ow instructions below to utilize JanitorLite to prohibit same card re entering and re exiting through the same door 1 Connect a secondary reader to MT180 via Drive RS232 NOTE While MT180 serves as an...

Page 45: ...se and click Append Entity to add a new con troller The Controller Management screen appears 8 Enter the controller name MT180 for example in the field of ContorllerName 9 Input the IP address of the...

Page 46: ...er group The User Group Setting window appears 14 Enter the user group name Demo for example Click Apply and then OK to return to the User Group Setting window 15 Right click the desired group Demo in...

Page 47: ...card number 19 Click OK to return to the User Group Setting window 20 Click Permit Permit Management 21 Select the desired user group Demo in this case and click Setting on the toolbar The control le...

Page 48: ...nd to send this command to controller immediately A pop up window appears with message Setting Successfully 25 Under Entrance Guard Weekly Plan tab select a desired weekday Monday for example 26 Doubl...

Page 49: ...the standby screen indicating re exiting is not allowed Scenario II Re Entering Swipe your card on the internal reader message Entrance with the user name APB in this case displays on the standby scr...

Page 50: ...external reader message Re Exiting with the user name APB in this case displays on the standby screen indicating re exiting occurs If you utilize JanitorLite Click Report Access Report Under the Condi...

Page 51: ...ty trigger Relay x 2 electrical door lock alarm I O Expansion Drive RS232 x 1 secondary reader Digital inputs x 3 Digital outputs x 3 Proximity Reader optional EM 125kHz HID 125kHz Mifare 13 56MHz ISO...

Page 52: ...have six regional services center Choose your region to get our quick support and their contact information can be found in our websites provided as below Region Website Global Operation Center www un...

Reviews: