background image

 

 

                                           

      02/05/2018 

www.uniteck.fr 

CO00208

 

 

 

FR

 

EN

 

ES

 

UNIMOS

 

 

80/24.2 – 120/24.2 – 160/24.3 – 200/24.3 

 

 

 

 

 

 

 

 

  

 

IMPORTANT  

 

 

   

 

 

 

 

 

 

 

 

FR

 

EN

 

ES

 

Veuillez respecter impérativement les polarités lors du raccordement de votre répartiteur 

aux batteries. L'inversion de polarité peut occasionner des dommages irréversibles à votre 

produit, dommages non couverts par la garantie.

 

Please imperatively respect the polarities when connecting your charge isolator with 

batteries. A polarity reversal may damage irreversibly your product, these damages are not 

covered by the warranty.

 

Por favor respete imperativamente las polaridades cuando conecta su separador de cargar 

con baterías. La inversión de polaridad puede ocasionar daños irreversibles a su producto, 

daños no cubiertos por la garantía.

 

!

 

Summary of Contents for UNIMOS 80/24.2

Page 1: ...sibles votre produit dommages non couverts par la garantie Please imperatively respect the polarities when connecting your charge isolator with batteries A polarity reversal may damage irreversibly yo...

Page 2: ...artiteurs diode ou aux r partiteurs MOSFET de vieille g n ration les r partiteurs de charge Unimos sont dot s de composants de derni re g n ration permettant des performances in gal es par rapport au...

Page 3: ...outes les batteries doivent tre de m me tension 12V ou 24V S assurer que la source de charge soit arr t e et reste arr t e durant l installation Installer votre r partiteur Unimos au plus proche de la...

Page 4: ...ple de serrage recommand 20 Nm SCH MA DE CABLAGE UNIMOS 160 24 3 ET UNIMOS 200 24 3 Couple de serrage recommand 20 Nm Batterie de d marrage Batterie de d marrage uniquement pour les d marreurs r gul s...

Page 5: ...e au c ble n gatif de l installation BAT 2 P le positif de la batterie de d marrage pour UNIMOS 80 120 24 2 ou de servitude secondaire pour UNIMOS 160 200 24 3 IG La connexion IG permet de d marrer le...

Page 6: ...tterie accept e 12 ou 24V Nombre de sorties 2 2 3 3 CHARGE Type de chargeur Alternateur Chargeur de batterie Courant de charge max BAT 1 BAT 2 BAT3 80 A 80 A 120 A 80 A 160 A 160 A 120 A 200 A 160 A 1...

Page 7: ...oivent tre r alis s conform ment aux r glements du pays en vigueur en mati re d lectricit Le mat riel utilis dans votre installation tel que les connecteurs c bles fusibles sectionneurs doit tre adapt...

Page 8: ...Tension 2014 35 UE du 26 02 2014 Directive CEM 2014 30 UE du 26 02 2014 Directive ROHS 2011 65 UE du 08 06 2011 Il est pour cela conforme aux normes harmonis es EN 61000 6 3 2007 EMC Emission EN 61000...

Page 9: ...te d montage ou toute autre avarie due au transport En cas de panne retournez l appareil votre distributeur en y joignant un justificatif d achat dat ticket de sortie de caisse facture une note explic...

Page 10: ...diode isolators or old version of MOSFET isolators Unimos isolators are equipped with the latest generation components allowing unequalled performance compared to the current products on the market w...

Page 11: ...f the same voltage 12V or 24V Make sure that the charging source is switched off and remains switched off during installation Install your Unimos separator as close as possible to the charging source...

Page 12: ...120 24 2 Recommended tightening torque 20 Nm WIRING DIAGRAM UNIMOS 160 24 3 AND UNIMOS 200 24 3 Recommended tightening torque 20 Nm Starter battery Starter battery only in case of electronically regu...

Page 13: ...the negative cable of the installation BAT 2 Positive pole of starter battery for UNIMOS 80 120 24 2 or secondary battery for UNIMOS 160 200 24 3 IG The IG connection enables modern electronically reg...

Page 14: ...age accepted 12 ou 24V Number of outputs 2 2 3 3 CHARGE Charger type Alternator Battery charger Max load current BAT 1 BAT 2 BAT3 80 A 80 A 120 A 80 A 160 A 160 A 120 A 200 A 160 A 120 A Voltage drop...

Page 15: ...rried out in accordance with the country s electricity regulations in force The equipment used in your installation such as connectors cables fuses disconnectors etc must be adapted and in accordance...

Page 16: ...dated 26 02 2014 EMC Directive 2014 30 EU dated 26 02 2014 ROHS Directive 2011 65 EU dated 08 06 2011 For this reason it complies with the following European and national standards EN 61000 6 3 2007 E...

Page 17: ...r any other transport damage In the event of a malfunction return the product to your dealer by joining A dated proof of purchase sales receipt invoice etc A note explaining the fault Attention our af...

Page 18: ...de los repartidores con MOSFET de la generaci n anterior los repartidores de carga Unimos est n equipados con componentes de ltima generaci n que permiten un rendimiento inigualable en comparaci n con...

Page 19: ...el alternador Todas las bater as deben ser del mismo voltaje de 12V o 24V Aseg rese de que la fuente de carga est desconectada y permanezca desconectada durante la instalaci n Instale su Unimos lo m s...

Page 20: ...24 2 Par de apriete recomendado 20 Nm ESQUEMA DE CONEXI N UNIMOS 160 24 3 Y UNIMOS 200 24 3 Par de apriete recomendado 20 Nm Bater a de arranque Bater a de arranque S lo para arrancadores regulados el...

Page 21: ...ble negativo de la instalaci n BAT 2 Polo positivo de la bater a de arranque para UNIMOS 80 120 24 2 o servicio secundario para UNIMOS 160 200 24 3 IG La conexi n IG permite la puesta en marcha de mod...

Page 22: ...ater a aceptada 12 ou 24V N mero de salidas 2 2 3 3 CARGA Tipo de cargador Alternador Cargador de bater a Corriente de carga m x BAT 1 BAT 2 BAT3 80 A 80 A 120 A 80 A 160 A 160 A 120 A 200 A 160 A 120...

Page 23: ...s al menos una vez al a o Todos los trabajos deben realizarse de acuerdo con la normativa el ctrica vigente en el pa s Los equipos utilizados en su instalaci n como conectores cables fusibles secciona...

Page 24: ...8 Avenue de Rome Immeuble le Cassis 34350 Vendres Francia GARANT A La garant a cubre cualquier defecto o defecto de fabricaci n durante 1 a o a partir de la fecha de compra piezas y mano de obra La g...