background image

Installation & Maintenance Instructions

TX200™ 

Pressure Transmitter

Reading Office

Cutbush Park, Danehill, Lower Earley,
Reading, Berkshire. RG6 4UT. UK.
Tel: +44 (0)118 9311188  
Email: info@able.co.uk

Aberdeen Office

Unit 6 Airside Business Park, Kirkhill Industrial Estate, 
Dyce, Aberdeen. AB21 0GT. UK.
Tel: +44 (0)1224 725999
Email: ab@able.co.uk

Internet: www.able.co.uk
e-procurement: www.247able.com
Registered in England No: 01851002
VAT No: GB 417 2481 61

Summary of Contents for TX200

Page 1: ...ading Berkshire RG6 4UT UK Tel 44 0 118 9311188 Email info able co uk Aberdeen Office Unit 6 Airside Business Park Kirkhill Industrial Estate Dyce Aberdeen AB21 0GT UK Tel 44 0 1224 725999 Email ab able co uk Internet www able co uk e procurement www 247able com Registered in England No 01851002 VAT No GB 417 2481 61 ...

Page 2: ...p testing The units may require re adjustment These products do not have any field replaceable parts Any substitution of components may impair suitability for Class I Division 1 TX200 Pressure Transmitter The epoxy resin shall not be subjected to a temperature greater than 125 C Part I Installation Tools Needed Adjustable Wrench Mounting Always locate units where shock vibration and ambient temper...

Page 3: ...would be spanned so that the 4 mA output signal 0 psig and the 20 mA output signal 1500 psig 103 4 bar 2 Connect the transmitter to a 24 volt nominal voltage source through a 100 ohm load resistor Reference Diagram 1A Connect a digital voltmeter across the terminating resistor The output across the resistor will be 100 mVolts mA 3 Zero the transmitter if necessary 4 Turn the Cal switch to the on p...

Page 4: ...6 0 54 13 7 B G 1 2 female 1 3 8 1 01 25 7 C 7 16 20 SAE male 15 16 0 77 19 6 D HM4 Autoclave male 15 16 1 10 27 9 E HM6 Autoclave male 15 16 1 29 32 8 F LM4 Autoclave male 15 16 1 18 30 0 G LM6 Autoclave male 15 16 1 32 33 5 H G 1 4 male 15 16 1 03 26 2 J G 1 2 male 1 3 8 1 78 45 2 Wire Color Coding Red VDC Black VDC Green Earth Ground Blue 1 5 VDC Output Option M204 only 03 0 to 15 psis 04 0 to ...

Page 5: ... on a switch can cause damage even on the first cycle Wire unit according to local and national electrical codes using wire size recommended in installation sheet Do not mount unit in ambient temp exceeding published limits LIMITED WARRANTY Seller warrants that the product hereby purchased is upon delivery free from defects in material and work manship and that any such product which is found to b...

Reviews: