background image

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Catalog No. 04-53480237-01

Printed in U.S.A.

Form 48/50-91SI

Pg 1 

1-19

Replaces: 48/50-84SI

Installation Instructions

Part No: CRSOUBLN001A00, CRSOUBLN002A00, CRSOUBLN003A00, 

CRSOUBLN004A01, CRSOUBLN005A01, CRSOUBLN006A00 and 

CRSOUBLN007A00

SAFETY CONSIDERATIONS

Installation and servicing of air-conditioning equipment can be
hazardous due to system pressure and electrical components.
Only trained and qualified service personnel should install, re-
pair, or service air-conditioning equipment.
Untrained personnel can perform basic maintenance functions
of cleaning coils and filters and replacing filters. All other op-
erations should be performed by trained service personnel.
When working on air-conditioning equipment, observe precau-
tions in the literature, tags and labels attached to the unit, and
other safety precautions that may apply.
Follow all safety codes, including ANSI (American National
Standards Institute) Z223.1. Wear safety glasses and work
gloves. Use quenching cloth for unbrazing operations. Have
fire extinguisher available for all brazing operations.

INTRODUCTION

This accessory package is intended for use with 48/50A,
48/50N and 48/50P units. See Table 1 for accessory package
usage. Part no. CRSOUBLN002A00 is for tandem compres-
sors. All other part numbers are for single compressor.
The following are the procedures to install the low sound com-
pressor blanket.

48/50P INSTALLATION

1.

 48/50P 030-060 unit sizes:
 a. Remove optional security grilles if present.
 b. Access compressor section through opening on end or

side of unit. See Fig. 1.

 c. Remove or open 2 compressor access panels or doors.

See Fig. 1-3.

48/50P 070-100 unit sizes:

a. Remove optional condenser grilles, if present.
b. Access compressors from side and end of the unit.

See Fig. 4.

WARNING

Electrical shock can cause personal injury and death. Shut off
all power to this equipment during installation. There may be
more than one disconnect switch. Tag all disconnect locations
to alert others not to restore power until work is completed.

Table 1 — Accessory Package Usage

UNIT

SIZE

ACCESSORY PART NO.

QTY

48/50P

with and without

Digital Compressor Option

030,035

CRSOUBLN001A00

2

040

CRSOUBLN001A00

3

050-075

CRSOUBLN001A00

4

090-100

CRSOUBLN001A00

6

48/50A

without 

Digital Compressor Option

020, 025, 027 CKT A

CRSOUBLN002A00

1

020, 025, 027 CKT B

CRSOUBLN003A00

1

030 CKT A, CKT B

CRSOUBLN002A00

2

035 CKT A

CRSOUBLN002A00

1

035 CKT B

CRSOUBLN005A01

2

040, 050 CKT A, CKT B

CRSOUBLN005A01

4

060 CKT A, CKT B

CRSOUBLN001A00

4

48/50A

with 

Digital Compressor Option

020, 025, 027 CKT A

CRSOUBLN002A00

1

020, 025, 027 CKT B

CRSOUBLN007A00

1

030 CKT A

CRSOUBLN004A01

2

030 CKT B

CRSOUBLN002A00

1

035 CKT A

CRSOUBLN002A00

1

035 CKT B

CRSOUBLN005A01

2

040, 050 CKT A, CKT B

CRSOUBLN005A01

4

060 CKT A, CKT B

CRSOUBLN006A00

4

48/50N

with and without 

Digital Compressor Option

75 Ton

CRSOUBLN001A00

5

90 and 105 Ton

CRSOUBLN001A00

6

120, 130, and 150 Ton

CRSOUBLN001A00

8

48/50A, 48/50N, 48/50P

Compressor Sound Blanket Accessory

Summary of Contents for Carrier CRSOUBLN001A00

Page 1: ...the procedures to install the low sound com pressor blanket 48 50P INSTALLATION 1 48 50P 030 060 unit sizes a Remove optional security grilles if present b Access compressor section through opening o...

Page 2: ...5 5 Wrap the blanket around the compressor terminal box See Fig 6 6 Attach the hook and loop strips on the vertical seam to secure the blanket to the compressor See Fig 6 7 Attach top flap of blanket...

Page 3: ...ssors through side of unit 48 50A 040 050 unit sizes a Open the compressor access doors See Fig 9 b Access compressors through end of unit 48 50A 060 unit sizes with round tube plate fin condenser coi...

Page 4: ...Fig 5 for single compressors and Fig 13 for tandem compressors 5 Wrap the blanket around the compressor terminal box See Fig 6 for single compressors and Fig 13 for tandem compres sors 6 Attach the h...

Page 5: ...ssors Fig 13 Align and Secure Blanket Slots with Suction Tube for Tandem Compressors Fig 14 Attach Top Flap of Blanket with Hook and Loop Strip for Tandem Compressors COMPRESSORS TUBING BLANKET A48 86...

Page 6: ...blanket near suction tube with the hook and loop strips See Fig 5 6 Wrap the blanket around the compressor terminal box See Fig 6 7 Attach the hook and loop strips on the vertical seam to secure the b...

Page 7: ......

Page 8: ...ht to discontinue or change at any time specifications or designs without notice and without incurring obligations Catalog No 04 53480237 01 Printed in U S A Form 48 50 91SI Pg 8 1 19 Replaces 48 50 8...

Reviews: