Summary of Contents for UX3500

Page 1: ... warranties of merchantability or fitness for any particular purpose In no event will UTAS Inc be liable to any person for any direct indirect special or other consequential damages arising from the use of any information contained herein This Manual is subject to change without prior notice All proprietary information contained herein are protected under copyright This Manual should not be copied...

Page 2: ...bout Program 1 UIPC Editor Configuration 2 Menu Icon 3 Project 4 External Buttons LCD Touch Panel 5 Properties Buttons 6 Library 7 Database Management III To Make New Project 1 To configure Page Screen 2 To setup Button actions IV Test Transmission V Examples of Screen Configuration CONTENTS 3 5 8 9 10 12 13 14 15 19 24 27 32 33 ...

Page 3: ...00GS HDD Space availability of 200M or more Space availability of 1G or more OS Window XP Vista PC specification for PC Editor 1 Execute UIPC Editor msi to start installation of the UIPC Editor program The installation program is contained in the CD provided at the time of purchase 2 Read the License Agreement check I Agree then click on Next Requirements to run UIPC Editor are I Program Installat...

Page 4: ...be installed then click on Next The installation path for UIPC Editor is UIPC Editor in Program Files in C Drive as default 4 Installation will take about 2 3 minutes to complete 5 When installation is complete click on Close and execute UIPC Editor ...

Page 5: ...al uses its own USB port for communication with a PC through which it receives data generated on UIPC Editor To enable this USB communication the ActiveSync program must be installed 2 Installation of Microsoft ActiveSync 2 Select I Agree to the User License Agreement and click on Next 3 Enter the User information then click on Next Window Vista Users must install Window Mobile Sync Center ...

Page 6: ...4 Select the drive and the folder to install ActiveSync then click on Next to start installation 6 5 Installation is under progress 6 Click on Finish to complete installation of the ActiveSync program ...

Page 7: ...iveSync before using UIPC Editor Window Vista users must install Window Mobile Device Center instead of ActiveSync Window Mobile Device Center can be found at and downloaded from the Microsoft web site 8 On the following screen select the Search menu to view folders and files stored in UX3500 As long as UX3500 is connected properly to your PC you can send data that are processed on UIPC Editor ...

Page 8: ...sable User Account Control 3 Untick Protect PC with User Account Control leaving the box blank 3 Setup for Window Vista Users Window Vista users must release the Vista security settings to ensure normal operation of UIPC Editor 4 Click on Confirm and restart the PC ...

Page 9: ...ctivity Properties edit screen that sets functions for the external buttons of UX3500 and 2 Page edit screen that configures the Touch Panel LCD screen Basic Menu Icon Activity Page configuration Selectable Libraries Label Image Action External buttons of UX3500 To create New Activity Page Touch Panel LCD Screen To Edit button actions Device Code Library ...

Page 10: ...t entry to the screen during screen setup Alt T System IR Icon to add the IR Icon The IR icon will only appear when the terminal sends control commands System Text Field to add a Text Field Text Field informs you automatically of name of each page System Battery to add the Battery icon that indicates the battery level System Time to add the Clock System Date to add the Date System Page Number to i...

Page 11: ...des help topics 6 Icon Basic Menu Icons are available for easy editing work Open Project to open the saved project file Save Project to save the current project Cut to cut off the selected item Copy to copy the selected item Paste to paste the cut or copied item Delete to delete the selected item My Database to open the database you had saved Emulator to execute Emulator to check data virtually Do...

Page 12: ... Pages and HOME 3 Project System Screens and functions that are configured in the System will apply to all pages globally Basic items such as IR Icon Time Date Battery and Setup Button are the main constituents but the frequently used buttons can also be added for your convenience e g Receiver Volume Light On Off and so on Home HOME is the first page of UX3500 HOME can be configured with devices t...

Page 13: ...ystem Property buttons become activated Select an Action and enter its value see P27 for adding Button Actions Buttons of the LCD Touch Panel can be customized From UIPC Editor use the Mouse to move and download backgrounds or buttons to UX3500 The same screen will be shown in UX3500 2 LCD Touch Panel New Panel Basic panels will be newly created New Text Basic texts will be newly created System Ic...

Page 14: ...e Up Down In case of multiple Actions the selected Action can be moved to another location or in another sequence Names of New Activity and each page can be changed 2 Image You can change Item Images such as Buttons and Panels of the screen Add Image To add new image to the selected item Save Image To save the selected item Delete Image To delete the selected image Only the image not the Item will...

Page 15: ...checked by In Project are added to Device Library See if correctly ticked Replace to replace data of the selected device with other data Function Setup to setup IR RS232 values for the selected device data Delete to delete the selected device from Library Devices added to In Project from My Database Data item of each device button Data items of the Device Functions can be entered as the Button Pro...

Page 16: ... IR device and Relay device Select ID and Channel to setup ID of the selected Extender and channels Upon completion click on Close to close the window Select and tick the device from Device Library to connect to the Extender Select Port Select the corresponding port of the Extender that is connected to a device The ID located at the bottom of Extender and the CH switch must match with the setup va...

Page 17: ... name of your choice Buttons In addition to the basic buttons provided with the product you may create your own buttons Newly added background images C Save in any folder of your choice through this path C Program Files UIPC Editor Gallery button folder of your choice b Size of both buttons must be the same and saved as a png or a jpg file 기본 제공 버튼 이미지 a Buttons should be created into two categori...

Page 18: ...d to a png file Save these files in any folder through this path C Program Files UIPC Editor Gallery Panel any file name of your choice Example of a Panel applied screen Panel images The png file format is recommended to keep Panel images translucent jpg without the transparent effect will completely shadow the background ...

Page 19: ...eck My Database to check if the list of selected devices is saved 2 My Database Search to search the object to control by device name or by brand In Project Select the control code from the list saved in My Database which corresponds to the devices and click on In Project The selected date is ticked Check Device Library When the My Database window is closed the selected list is saved in Device Lib...

Page 20: ...Brand Name to register name of the manufacturer c Model Name to enter model name in full for easier control d Select IR for Control Type Check all entries and click on Add to register the device Click on Function Item to register the name of Remote Control button for learning Select the item for Learn and click on the Learn button Function Item When the Learn Ready window appears press a button on...

Page 21: ...l be marked with on Device Functions window This indicates that there is no IR code If a function has completed Learn it will be marked with Items after Learn Items before Learn Learning methods may vary depending on the type of Remote Controls For an ordinary Remote Control press and hold a Remote Control button until Learn is complete If Volume or Menu Cursor staggers during the operational test...

Page 22: ...ems are entered then click on Add to register the device Select a code type ASCII or HEX for Control Code Most RS232C RS485 compatible devices use HEX Upon entering the above values click on Device Function Function Items Examples of Functions Items ALL ON ALL OFF Power On Power Off Input 1 Input 2 RGB Video Once registered click on Device Properties to enter setup values for the RS232C communicat...

Page 23: ...vice Functions window The Function item with code will be marked with Item with Code Item without Code 6 Save Open from My Database If you wish to reinstall or use UIPC Editor in another PC save the MyDB file separately The MyDB file is located in the UIPC Editor Folder through this path C Program Files UIPC Editor Copy MyDB save separately and Paste onto the UIPC Editor Folder of the new PC When ...

Page 24: ...figured in the System Page are shown globally in all pages It is recommended that icons are aligned in a linear fashion either at the top or the bottom of the screen rather than in the middle All buttons configured in the System Page are shown globally in all pages These include Date Time Battery and Setup among others 3 Home Page Configuration Select Background Select and move a background item b...

Page 25: ...e are many button items to be used for a remote control add a New Page to Activity 5 Item Align Position of the items in Edit Screen can be aligned Item Select Drag and select items for alignment in the edit screen The fiducial item for alignment will be outlined in red Align Select The method of alignment can be selected From the fiducial item you can select alignment to the left the center the r...

Page 26: ...evenly aligned f Increase Horizontal Spacing The horizontal space between the selected items increases in the regular proportion 2 pixel g Decrease Horizontal Spacing The horizontal space between the selected items decreases in the regular proportion 2 pixel h Remove Horizontal Spacing Items are aligned in such a way that they concatenate horizontally 8 Item Alignment by Priority Order of items ca...

Page 27: ...tivity in the order or the reverse order of registration default 6 Volume Button Sets to execute the volume control function of each device 7 Channel Button Sets to execute the channel select function of each device 8 Cursor Control Button Sets to execute functions such as Search Menu 9 OK Button Sets to execute functions such as OK 10 MENU Button Sets to execute the Open Menu function 11 EXIT But...

Page 28: ...checks the ID number of a button and select the button to be linked Select Activity Select Page Select Button Set Delay Time Add Jump Action To jump to a particular page Often used to move to each Activity from the Main Control page a Page Jump To move to a particular page The Activity and the Page to be jumped to must be designated Select Page Select Activity Select Jump Action b Page Up To move ...

Page 29: ... Library to the selected button a Add Device to Device Library To add data of device to be controlled to My Database c Device Select the controller d Select Function From the data of the selected controller select Function to add Devices added to My DB Controller port setup Data of control device Select Function Select Controller b Add Function Click on to add Functions Please enter correct partic...

Page 30: ...mand Enter the code of the button to be controlled Select either ASCII or HEX c Select Extender Select the Extender to which the device is connected d Select Port Select the Port of Extender to which the device is connected Please refer to the manufacturer s information on communication methods and control codes Add Channel Macro Action To enter a particular channel globally on the device that has...

Page 31: ...31 Move Down Move Up To prioritize Actions for a button with many actions Action Delete To delete unwanted Actions Move UP Move Down ...

Page 32: ...heck the LCD screen configuration and the external hard buttons also 32 1 Emulator Test 1 To Execute Emulator If data is not saved Emulator may not work Emulator Execution Screen External hard buttons Connect UX3500 to a PC via USB 2 Test for Device Operation Execute Emulator to test each of the buttons Property of each button is delivered to UX3500 via USB so as to enable Actions If every thing w...

Page 33: ...o connect a PC to UX3500 using the USB cable provided with the product Check Active Sync ActiveSync is automatically executed once the connection between a PC and UX3500 is correctly made Download to UX3500 or Ctrl D Upon data transmission from UIPC Editor the screen of UX3500 is changed to Upload Download Transmission Complete Upon transmission UX3500 is automatically re booted and the screen con...

Page 34: ...V Examples of Screen Configuration 34 Home Page Home Page Lighting Dimming Control LED TV DVD Player Lighting Scene Control ...