UTLCD1
GENERAL MAINTENANCE
Warning
If the current test leads are worn, replace test leads with identical or
compatible leads: 1000V 10A.
Warning
To avoid personal injury or damage to the Detector, DO NOT wet the inner
parts of the Detector. Regularly clean the Detector case with damp cloth and a small
amount of detergent. Do not use abrasives or chemical solvents.
REPLACE BATTERIES & FUSES
Warning
To avoid incorrect readings and possible electric shock or personal injury,
when “
” appears on the display, replace the battery immediately. Turn off the meter
and disconnect the test probe from the meter before opening the back cover to replace
batteries or fuses. Gain access to batteries and fuse by using a screwdriver to loosen the
battery cover screws on the back of the meter and removing the cover.
GENERAL SPECIFICATIONS
▶
Operating Category: 600V CAT III, pollution grade: 2.
▶
Operating Elevation (< 2000 m)
▶
Operating Conditions: 0~40°C, <80% RH (do not use meter when temperature <10°C).
▶
Storage Conditions: -10~60°C, <70% RH (remove the battery).
▶
Temperature Coefficient: 0.1× Accuracy/°C(<18°C or >28°C).
▶
Maximum Voltage between measurement end and ground: 600V DC or 600V AC RMS.
▶
Fuse protection: mA Grade: fuse F400mA/500V and 10A Grade: fuse F10A/500V
▶
Sampling rate: about 3 times/second.
▶
Display: 3 1/2 digits 2,000 count LCD display.
▶
Power supply: AAA 1.5V batteries.
ELECTRICAL SPECIFICATIONS
WARRANTY
The UTL Combustible Leak Detector (UTLCD1) is warranted to be free from defects in
materials and workmanship for a period of one year from the date of purchase. This war-
ranty does not cover fuses, disposable batteries, or damage from drops, neglect, misuse,
alteration, contamination, or abnormal conditions of operation or handling. Resellers are
not authorized to extend any other warranty on behalf of UTL. To obtain service during the
warranty period, contact your nearest UTL service center directly. For full warranty details
visit us online www.utltest.com.
DC VOLTAGE
Range
Resolution Accuracy
200mV
0.1mV
± (0.5% + 3 dgts)
2V
1mV
20V
10mV
200V
100mV
600V
1V
± (0.8% + 3 dgts)
Overload protection:
600V
AC VOLTAGE
Range
Resolution Accuracy
400V
0.1V
± (1.2% + 10 dgts)
600V
1V
Overload protection:
600V
DC CURRENT
Range
Resolution Accuracy
20mA
0.01mA
± (1.0% + 5 dgts)
200mA
0.1mA
10A
0.01A
± (2.0% + 10 dgts)
RESISTANCE
Range
Resolution Accuracy
200.0Ω
0.1Ω
± (0.8% + 5 dgts)
2.000kΩ
1Ω
20.00kΩ
10Ω
200.0kΩ
100Ω
2.000MΩ
1kΩ
DIODE
Range Test Current Open Test Circuit
1V
0.6mA
1.5V
BATTERY TEST
Range
Res.
Accuracy
1.5V
0.001V
40mV
9V
0.01V
40mA
12V
0.01V
40mV
CONTINUITY
Range
Open Test Circuit
<20Ω
Approx. 2.5V
GAS LEAK
DETECTOR
1. Press for 2 sec. to turn on (1 beep).
2. W
ait until detector is ready (2 beeps).
U
TLCD1
Gas
Instruction Manual
English
1
yr.
warranty
UTL Universal Trade Line
800-547-5740
www.utltest.com
00000 RA 08/13
Combustible Leak
Detector
P R O F E S S I O N A L V A L U E