background image

UVP201R

IP20

38x33x320mm

500 g

4.5-5h

UVC LED

45°

5mg/min

Type C

MAX 11W

275nm UVC

Intelligent UV & OZONE Disinfection Bar ULTIMATE

Center Irradiance: 

13500μW/cm²

Sensor angle 80°

Sensor distance 3m

REV-ODS  

Reverse Obstacle

Detection System

2cm 

Sensor distance

HBS

Human body 

sensing system

7.3V/4000 mAh

Li-ion

 UV: 2.5-3h

O3: 9-10h

Input

Output

5V     2A

Work light specifications

(In Bag)

UVC Light germicidal system intends for use in general purpose

Summary of Contents for UVP201R

Page 1: ... ULTIMATE Center Irradiance 13500μW cm Sensor angle 80 Sensor distance 3m REV ODS Reverse Obstacle Detection System 2cm Sensor distance HBS Human body sensing system 7 3V 4000 mAh Li ion UV 2 5 3h O3 9 10h Input Output 5V 2A Work light specifications In Bag UVC Light germicidal system intends for use in general purpose ...

Page 2: ...y independently hand held using it is usually able to kill 98 56 99 99 bacteria and virus on the surface or articles within 3 seconds During the fixed mode using ozone disinfection has two steps weak ozone and strong ozone Weak ozone step is designed to eliminate odor and formaldehyde in non confined space e g shoe cabinet wardrobe Strong ozone step is applicable to the disinfection in confined sp...

Page 3: ...hing it will automatically shut down after 30 seconds saving energy and protecting the environment if you short press or long press the handheld mode switch you can also shut down the light II Fixed Usage of Disinfection Bar Available to select the ULTRAVIOLET mode or OZONE mode for disinfection 1 Short press the switch of fixed mode to start up Meanwhile the intelligent HBS system will automatica...

Page 4: ...ctural degradation of plastic materials 2 Ultraviolet light can cause color shift or structural degradation of resin materials 3 Ultraviolet light can cause color shift or structural degradation of leatherwear 4 Ultraviolet light can cause color shift or structural degradation of organic compounds materials OZONE Equipment Damage Hazard 1 OZONE can cause color shift or structural degradation of pl...

Page 5: ... poisonous range The odor of ozone is not a reliable warning indicator due to the possibility of olfactory fatigue 9 Long term occupied enclosed spaces such as houses apartments hospitals and offices should have ozone volumes below 0 1mg m 0 05PPM The ozone concentration in the workplace i e occupational exposure limit is 0 1PPM 10 The amount of space used by the equipment used to place and use th...

Page 6: ...d object it is recommended that In order to achieve the radiation dose of 10 000 μW cm to meet the general needs of daily use the exposure time should be at least above 1 4 seconds In order to achieve the radiation dose of 100 000 μW cm to meet the needs of the professional environment the exposure time should be at least above 500 seconds To guarantee the ozone disinfect effect 1 Ozone can kill b...

Page 7: ...ABS plastics and no significant decomposition was found 6 It is recommended to avoid ozone disinfection of brightly colored leather silk and other items Some highly aged items such as natural rubber are also recommended to not undergo ozone disinfection Since ozone has an oxidative effect on most metals users should not use ozone disinfection on electronic products to avoid ozone damage to devices...

Page 8: ...structions WARNING UV C emitted from this product Avoid eye and skin exposure to unshielded product Follow installation instructions and user manual www uvpluss com AEC Lighting Solutions Co Ltd Add 2548 Bao an Highway Jiading District Shanghai 201801 China Tel 400 083 8757 www aeclight reel com ...