Installation instructions
Range hood
Operating mode: Extraction/recirculation
DSMS
1030019-R04
10/05/2017
1
The appliance should be installed by qualified personnel only.
Each step must be carried out and checked in full in the order specified.
Validity
These installation instructions apply to:
64005
(DSMS, construction width 11 cm)
General notes
If other firing systems are being used at the same time (e.g. wood, gas, oil or coal fired heating appliances), safe op-
eration is only possible providing a room negative pressure of 4 Pa (0.04 mbar) is not exceeded at the location of the
appliance.
Risk of toxic fumes! An adequate flow of fresh air must be guaranteed e.g. via non-closable openings in doors or
windows and in combination with an air-intake/exhaust-air wall box or by other technical means.
The use of the range hood together with a gas fired appliance is not permitted.
Efficient repairs can only be guaranteed if it is possible to de-install the complete appliance at any time without caus-
ing any damage.
Identification plate
▸
The identification plate is located in the base unit on the side panel of the fan motor.
▸
A second identification plate is included in the scope of delivery and should be retained for the purpose of appliance identifica-
tion.
Scope of delivery
S1 (12×)
M
U (2×)
E
S2 (4×)
A
T
F
G
N
L
T
V (2×)
R
K
A
Drip tray frame
N
Mains cable length 1.8 m
E
Control unit
Q
Flat channel system
F
Metal grease filter
R
Frame
G
Appliance housing
T
Exhaust air duct
K
Control cable
U
Spacer profile
L
Ventilation outlet
V
Connecting elements
M
Fan motor