Page 1: ...Range hood Mistral Bora Operating instructions V ZUG Ltd...

Page 2: ...for the purpose of the further development of the appliance is reserved Symbols used Indicates step by step instructions Describes how the appliance reacts to the steps taken Indicates a list Validity...

Page 3: ...3 2 Switching off 12 3 3 After running time 12 3 4 Clean Air function 13 3 5 Intensive level 13 3 6 Illumination 14 3 7 Saturation indicator for the grease filter 14 4 Care and maintenance 15 4 1 Cle...

Page 4: ...he first time The appliance must be installed and connected up to the electricity supply in accordance with the separate installation instructions The necessary work should be done by a qualified fitt...

Page 5: ...necessary Use original spare parts only Retain these operating instructions for future reference If you sell or pass the appliance on to a third party please ensure these operating instruc tions toge...

Page 6: ...e Constantly monitor the temperature of the cooking oil keeping it below the temperature at which it can catch fire Change the cooking oil regularly dirty oil catches fire more easily than clean oil C...

Page 7: ...adequate flow of fresh air must be guaranteed e g via non closable openings in doors or windows and in combination with an air intake exhaust air wall box or by other technical means When carrying ou...

Page 8: ...ntegrated non return valve and through the air duct to the outside 2 2 Recirculation model The cooking fumes and smells are filtered over the metal grease filter through an activated charcoal filter a...

Page 9: ...arcoal filter The extraction fan has 4 power levels Low Medium High and Intensive level Power levels 1 3 can be used for longer periods of operation The intensive level is for shorter bursts of intens...

Page 10: ...ction 1 Operating and display elements 2 Long life activated charcoal filter for recirculating air only 3 Halogen light 4 Metal grease filter 5 Glass panel fold away only Mistral 6 Air recirculation f...

Page 11: ...level 2 on off Power level 3 on off Intensive level on off After running time Clean Air function Illumination on off dimmed Grease filter saturation indicator Depending on the model and design the sp...

Page 12: ...tton to activate the after running time The button illuminates After running for 5 seconds at level 3 and then level 2 the appliance runs for 15 minutes at level 1 and then switches off We recommend s...

Page 13: ...appliance is switched on or off Press the button to switch on the intensive level for 5 minutes The button illuminates Power level runs for 15 minutes every hour When in use ensure there is a suffici...

Page 14: ...n indicator for the grease filter The display illuminates after 15 operating hours or at the latest 14 days after first being put into operation The saturation level is reached The grease filter must...

Page 15: ...n build up around the grease filter on the inside Clean using a slightly damp cloth and detergent if necessary and wipe dry Take care that no water gets into the housing If water gets into the housing...

Page 16: ...the grease filter 1 After cleaning reinstall the grease filter 1 Mistral Carefully fold the glass panel up again Mistral and Bora After cleaning hold the button depressed for at least 5 seconds The d...

Page 17: ...Select top and bottom heat or hot air and set the temperature to 100 C Place the filter on a wire shelf and allow to dry for 60 minutes Remove and clean the grease filter Remove the long life activat...

Page 18: ...ype max 20 watts Clean the ring and the glass Fit the ring and the glass back into the openings Mistral Carefully fold the glass panel up again Mistral and Bora Put back screw fuse or switch on circui...

Page 19: ...ctrical installations in the home is faulty Replace the fuse Reset the circuit breaker Interruption in the power supply Check the power supply The halogen light is faulty Replace the halogen light Pos...

Page 20: ...Grease filter is dirty Clean grease filter After cleaning hold the button depressed for at least 5 seconds The display goes out Possible cause Solution Clean Air function is activated Hold the button...

Page 21: ...and spare parts Please give model number and exact description when ordering parts Halogen light Metal grease filter Long life activated charcoal filter The halogen light is also available from speci...

Page 22: ...22 7 Technical data Electrical connection See identification plate Remove the grease filter The identification plate is located on the inside of the appliance...

Page 23: ...ocket or have the appliance disconnected from the mains by a qualified electrician Then cut off the mains cable Disposal The old appliance should not be discarded as worthless rubbish If disposed of c...

Page 24: ...24 9 Notes...

Page 25: ...10 Replacing 18 I Identification plate 22 Illumination Switching on off 14 Intensive level 13 L Light dimming 14 Long life activated charcoal filter 17 Cleaning and changing 17 M Maintenance 15 Metal...

Page 26: ...26 10 Index T Technical data 22 Trouble shooting 19 Type 2 U Use 12 V Validity 2...

Page 27: ...f the appliance is not working properly contact your nearest V ZUG Ltd Service Centre using freephone 0800 850 850 and stand in close proximity to the appliance Queries orders service agreement For ad...

Page 28: ...wer level 2 on off Power level 3 on off Intensive level on off After running time Clean Air function Illumination on off dimmed Grease filter saturation indicator J991 013 2 V ZUG Ltd Industriestrasse...