background image

© 2015 Vaddio - All Rights Reserved.  RoboSHOT QMini Systems - Document Number 342-0793 Rev B 

 

 

V

ADDIO

 

R

OBO

SHOT™

 

S

ERIES 

C

AMERAS

 

RoboSHOT 12 and RoboSHOT 30, HD Robotic PTZ Camera Systems 
featuring the Quick-Connect™ USB Mini with USB 2.0 Streaming  
 

 
 
 
 
 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 

 
 

 
 
 
 
 
 

 

 
 
 
 
 

 
 
 
 
 
 

 
 

System Model and Part Numbers 

RoboSHOT 12 QMini System, 999-9901-000 (North America), 999-9901-001 (Int’l)  
RoboSHOT 30 QMini System, 999-9911-000 (North America), 999-9911-001 (Int’l) 

RoboSHOT 30 QMini System, 999-9911-000W (North America), 999-9911-001W (Int’l) 

 

(Note:  The W suffix on the part number indicates white version of the RoboSHOT 30) 

 
 

RoboSHOT 30 

High-definition Robotic PTZ Camera for Medium to Large Venues
Featuring 30X Optical Zoom Lens and Tri-Synchronous Motion.
Available in Black or White finishes. 

RoboSHOT 12 

High-definition Robotic PTZ Conferencing Camera 
Featuring a 12X, 73º Wide Angle Optical Zoom Lens 
and Tri-Synchronous Motion  

Quick-Connect USB Mini System Interface 

Installation and User Guide 

Summary of Contents for RoboSHOT 12

Page 1: ...911 000 North America 999 9911 001 Int l RoboSHOT 30 QMini System 999 9911 000W North America 999 9911 001W Int l Note The W suffix on the part number indicates white version of the RoboSHOT 30 RoboSH...

Page 2: ...RoboSHOT HD Cameras RoboSHOT HD Cameras Document Number 342 0793 Rev B Page 2 of 60 Inside Front Cover Blank...

Page 3: ...tallation Basics 14 USB Mini Details 15 Worth Mentioning Again 15 Controlling the RoboSHOT Camera 16 IR Remote Commander 16 Telnet Control 16 RS 232 Control 16 Built in Webserver Control 16 Controllin...

Page 4: ...2 0 or IP Streaming Mode Page 35 Screen Shot Admin Menu Room Labels 36 Screen Shot Admin Menu Networking 37 Screen Shot Admin Menu Security 37 Screen Shot Admin Menu Diagnostics 38 Screen Shot Admin...

Page 5: ...ubject simultaneously which finally allows for smooth and manageable on air camera movements Yep there s no more pan tilt then zoom like other PTZ cameras available today The lens image sensor and ISP...

Page 6: ...operate any device if it has been dropped or damaged In this case a Vaddio technician must examine the product before operating To reduce the risk of electric shock do not immerse in water or other li...

Page 7: ...mp Switching Power Supply One 1 Euro Power Cord One 1 UK Power Cord One 1 6 1 83m USB Type A to Type B Cable Black One 1 Quick Setup Guide Full Manuals are downloaded from support vaddio com RoboSHOT...

Page 8: ...ositioning and are capable of the slowest of crawls which are suitable for on air use 3 IR Sensors IR sensors are built into the front of the RoboSHOT to receive IR signals from the IR Remote Commande...

Page 9: ...ovide ultra accurate and fast camera positioning and are capable of the slowest of crawls which are suitable for on air use 3 IR Sensors IR sensors are built into the front of the RoboSHOT to receive...

Page 10: ...VISCA protocol for camera control over a Cat 5e cable This port also acts as an IR Forwarding port with the Quick Connect SR or Quick Connect DVI HDMI interfaces which allows the user to transmit 3rd...

Page 11: ...nfiguration and operating note a The USB Mini interface will boot up in UVC streaming video mode A quick momentary touch will switch to web control mode and video will no longer pass This allows the a...

Page 12: ...0 2 720p 59 94 3 720p 50 Set the HD Video Select rotary switch to positions 0 3 or 6 only EZ POWER VIDEO Cat 5e Orange to Orange Laptop with UCC Application PC Video Out Ethernet Ethernet Ethernet Con...

Page 13: ...w HFOV The RoboSHOT 30 does not have a Super Wide mode 6 Set the Baud Rate DIP switch SW6 to 9600bps for most applications Default is 9600 bps 7 Setting all DIP switches DOWN with a power cycle loads...

Page 14: ...Please check all Cat 5 5e 6 cables for continuity in advance of final connection Use 568B straight thru termination Plugging the Power Cat 5 5e 6 cable into the wrong RJ 45 or using the wrong pin out...

Page 15: ...e USB Mini will show up on the connected computer as a UVC video USB 2 0 peripheral USB Mini Details The Quick Connect USB Mini Interface is a Cat 5 5e 6 camera interface and a USB 2 0 streaming appli...

Page 16: ...oboSHOT camera Camera Home Camera Pan left right and speed real time operation Camera Tilt up down and speed real time operation Camera Zoom zoom in out stop and speed real time operation Camera Store...

Page 17: ...Win7 8 Mac OS X 4 Cisco Jabber Win 7 Mac OS X 5 Vidyo Desktop Win 7 Mac OS X 6 Google Plus Win 7 7 Adobe Connect 8 Win 7 Mac OS X 8 LifeSize ClearSea Win 7 9 GoToMeeting Citrix Win 7 Mac OS X 10 Polyc...

Page 18: ...tic IP can be assigned either through the network or directly to a computer using a cross over cable Depending on the age of the computer you may not need a cross over cable Either way the steps are t...

Page 19: ...e system is on then the button will be blue and controls will be visible If the button is red no controls are accessible and the screen states Device is in standby Click to power up then you ll know w...

Page 20: ...ync a Position the first preset click on Store Preset and click on Preset 1 Check the Save with Tri Sync box Move the tri Sync speed slider to about the approximate position above about 1 3 up the spe...

Page 21: ...e security page which will be reviewed at a bit later in the tour allows the Admin to set the system to allow automatic guest access to the main camera control page If guest access is turned on by the...

Page 22: ...hen the camera powers up The pull down menu will allow the selection of one of the 6 factory scenes or one of the 3 custom scenes 3 CCU Scenes Click on any of these 9 buttons to load one of the CCU sc...

Page 23: ...slider Note If the detail is too high the video can look grainy and appear noisy too Chroma Move the adjustment slider as required for the amount of Chroma Color Vibrancy desired A numeric value will...

Page 24: ...ameters Notes If the LAN has a DHCP dynamic host configuration protocol server then the IP address gateway and routing information will automatically be assigned The software is defaulted to DHCP and...

Page 25: ...are made click on Save to store the change it s best to write down the new names and passwords A Guest Access check box is provided to let any user access the camera control page without logging in An...

Page 26: ...ystem version Pan Tilt Motor Versions and Sensor version are displayed in this section 4 Rear DIP Switch Status The DIP Switches on the camera are read and displayed for the Admin s reference This inf...

Page 27: ...contact Vaddio Tech support for assistance with updates Please read and completely understand the pop up warnings as it is easy to lose patience waiting for updates Click on continue to start the upda...

Page 28: ...hone numbers and e mail manuals FAQ s and System information is listed on support vaddio com This concludes the RoboSHOT Screen Shot Tour Up next the Quick Connect USB Mini Screen Shot Tour TECHNICAL...

Page 29: ...wsers that work with Quick Connect USB Mini include Chrome latest version Firefox latest version Internet Explorer versions 8 through 11 and Safari versions 6 and 7 These browsers have been tested tho...

Page 30: ...d Zoom controls can be adjusted with the three 3 sliders in this section For tighter shots it is recommended that the slower speed is used These controls are for real time camera movements only 4 Came...

Page 31: ...ync d Position the first preset click on Store Preset and click on Preset 1 Check the Save with Tri Sync box Move the tri Sync speed slider to about the approximate position above about 1 3 up the spe...

Page 32: ...Login for the Admin is on the Camera Control page Screen Shot Admin Menu Camera Control Page From the Admin Menu Camera Control Page all 10 menu buttons are accessible These menus on the left of the...

Page 33: ...ory scenes or one of the 3 custom scenes 3 CCU Scenes Click on any of these 9 buttons to load one of the CCU scenes into the camera These Scenes can be fine tuned if changes are needed and stored into...

Page 34: ...e will be displayed in the box to the right of the slider Detail Move the adjustment slider as required for amount of detail Aperture desired A numeric value will be displayed in the box to the right...

Page 35: ...fferent UC conference rooms and have the ability to assign the PC s USB resources to that room 2 Color Space The UVC drivers will negotiate the color depth but this parameter allows the user to reduce...

Page 36: ...f 60 Screen Shot Admin Menu Room Labels The Room Labels menu allows the administrator to label the company name room name room phone and help phone on a per QC USB basis The labels appear on every pag...

Page 37: ...er the USB port Screen Shot Admin Menu Security The Security menu allows the Admin to UPDATE user PASSWORD and UPDATE admin PASSWORD The default user password is password The default admin password is...

Page 38: ...Quick Connect USB and attached camera The log can be downloaded and refreshed at the bottom of the screen Screen Shot Admin Menu System Menu The System Menu is where the System Info is displayed and F...

Page 39: ...contact Vaddio Tech support for assistance with updates Please read and completely understand the pop up warnings as it is easy to lose patience waiting for updates Click on continue to start the upda...

Page 40: ...and e mail manuals FAQ s and System information is listed on this page Have the System page open when calling Vaddio Tech Support This concludes the Screen Shot Tour for the Quick Connect USB Mini The...

Page 41: ...ible through external control Aperture Detail 16 Steps accessible through external control Control Interface s RS 232 API Modified VISCA Emulation TTL signal level Baud rate 9600 bps and 38 400 bps 1...

Page 42: ...ernal AF Zoom Trigger AF Activate Internal Time 8x 01 04 57 00 FF 8x 01 04 57 01 FF 8x 01 04 57 02 FF 8x 01 04 27 0p 0q 0r 0s FF AF movement mode pqrs movement time rs Interval CAM_IRCorrection Standa...

Page 43: ...4 3D 02 FF 8x 01 04 3D 03 FF 8x 01 04 3D 06 FF 8x 01 04 2D 00 0q 0r 0s 00 00 00 00 FF WD On WD Off VE On p Display brightness level 0Dark 6Bright r Brightness compensation selection 0 Very dark 1 Dark...

Page 44: ...Color Hue Setting 0h 14 degrees to Eh 14 degrees CAM_GammaOffset Direct 8x 01 04 1E 00 00 00 0s 0t 0u FF s Polarity offset 0 is plus 1 is minus tu Offset s 0 00h to 40h RoboSHOT 12 00h to 10h RoboSHOT...

Page 45: ...B Gain CAM_AEModeInq 8x 09 04 39 FF y0 50 00 FF y0 50 03 FF y0 50 0A FF y0 50 0B FF y0 50 0D FF Full Auto Manual Shutter Priority Iris Priority Bright CAM_ShutterPosInq 8x 09 04 4A FF y0 50 00 00 0p...

Page 46: ...gister No 00h to 7Fh pp Register Value 00h to FFh CAM_ColorEnhanceInq 8x 09 04 20 FF 8x 09 04 50 FF y0 50 mm 00 pp qq rr ss tt uu FF y0 50 02 FF y0 50 03 FF mm Threshold level pp Y fixed color for hig...

Page 47: ...Example COMMAND camera home get RESPONSE OK Syntax Error Example COMMAND camera right pan RESPONSE ERROR Additional programming controls associated with the terminal protocol includes CTRL 5 Clears th...

Page 48: ...nc at speed 15 Camera Tilt NAME camera tilt Tilts the camera up or down SYNOPSIS camera tilt up down stop 1 20 DESCRIPTION Method used to tilt the camera OPTIONS up Move the camera up down Move the ca...

Page 49: ...t 5 Pans the camera left at a speed of 5 camera tilt up 10 Tilts the camera up at a speed of 10 camera pan stop Stops the camera from panning camera home Move camera to home position camera standby to...

Page 50: ...AMPLES camera ccu scene recall factory 2 Recalls the factory scene stored at index 2 Camera CCU Set NAME camera ccu set Sets and gets the CCU Settings SYNOPSIS camera ccu set auto_white_balance on off...

Page 51: ...at index 2 camera ccu get all Gets all current CCU settings Camera Focus NAME camera focus Moves the focus near or far SYNOPSIS camera focus near far stop 1 8 mode auto manual DESCRIPTION Method used...

Page 52: ...ine is read Listed below are examples of history expansion Substitute the last command line N Substitute the Nth command line absolute as per history command N Substitute the command line entered N li...

Page 53: ...8 116 Netmask 255 255 255 0 Gateway 10 10 8 100 Returns the current network settings for mac addres ip address netmask and gateway Network NAME network Gets the current network settings or pings an I...

Page 54: ...t on reboot EXAMPLES system factory reset get factory reset software off factory reset hardware Hardware reset is designated by rear panel DIP switches in down position off Returns the factory reset s...

Page 55: ...ry reset software on factory reset hardware off system reboot Broadcast message from root Thu Jan 1 03 27 40 2266 The system is going down for a reboot NOW system reboot 30 OK The system is going down...

Page 56: ...his equipment ICES 003 Compliance This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadi...

Page 57: ...xpressly approved by Vaddio can affect emission compliance and could void the user s authority to operate this equipment ICES 003 Compliance ICES 003 Issue 4 2004 This digital apparatus does not excee...

Page 58: ...an RMA from Vaddio s technical support Provide the technician with a return phone number e mail address shipping address product serial numbers and original purchase order number Describe the reason...

Page 59: ...RoboSHOT HD Camera Systems RoboSHOT HD Cameras Document Number 342 0793 Page 59 of 60 Inside Back Cover Mostly Blank...

Page 60: ...2015 Vaddio All Rights Reserved Reproduction in whole or in part without written permission is prohibited Specifications and pricing are subject to change without notice or obligation Vaddio RoboSHOT...