Page 1: ...Comfort for your home aroTHERM plus Air to water heat pumps aroTHERM plus Installer s Quick Guide...

Page 2: ...ion The non observance of the instructions delivered with the appliance can lead to malfunctions of the appliance and can result in death or serious injuries Some characteristics of the appliance show...

Page 3: ...e aroTHERM plus system Choose your system schematic 17 Start with the hydraulic connection 18 Proceed to the power supply and eBUS connection 19 Choose your indoor unit uniTOWER hydraulic module or he...

Page 4: ...7 3 92 10 8 3 63 3 C 13 9 13 4 12 9 12 1 11 2 0 C 15 2 14 6 14 1 13 2 12 3 2 C 16 15 5 14 9 13 9 13 Plan your work Select the correct aroTHERM plus to fit your needs Performance data When designing a...

Page 5: ...Guide aroTHERM plus 11 2020 Back to main menu Product dimensions 90 26 122 765 mm 449 mm 1100 mm 3 5kW 5kW 965 mm 7kW 1565 mm 10kW 12kW 185 kg 270 106 740 180 180 477 14 14 133 kg 121 kg G 1 unboxed...

Page 6: ...20 30 40 50 60 0 5 10 15 Distance from heat pump m Sound pressure level dB A 58 9 52 9 49 4 46 9 44 9 43 3 40 8 38 9 37 3 35 4 49 0 43 0 39 5 37 0 35 0 33 4 30 9 29 0 27 4 25 5 aroTHERM VWL 125 5 230...

Page 7: ...e perfect space for your installation A quiet space for your installation Whilst the aroTHERM plus has been accredited by Quiet Mark for it s super low noise levels When siting pay consideration to be...

Page 8: ...drains and openings In the unlikely event of a refrigerant leak the gas needs to be allowed to disperse to stop the risk of the gas igniting Follow the diagrams below to ensure adequate clearance C D...

Page 9: ...9 Installer s Quick Guide aroTHERM plus 11 2020 9 Back to main menu A vented space for perfect operation Do Don t Operation clearances 0 6m 0 1m 0 5m 0 25m 0 2m 1 m...

Page 10: ...10 Installer s Quick Guide aroTHERM plus 11 2020 10 Back to main menu Install several aroTHERM plus in one spot quiet vented safe Do Don t 500 mm 500 mm...

Page 11: ...t point of use uniSTOR Heat Pump pre plumbed cylinder range Storage temperature in cylinder 150 200 250 300 Amount of useable hot water at point of use litres 50o C 200 267 333 400 55o C 225 300 375 4...

Page 12: ...e for deicing aroTHERM plus Minimum open volume required aroTHERM plus 3 5 and 5kW 15 litres aroTHERM plus 7kW 20 litres aroTHERM plus 10 and 12kW 45 litres System expansion vessel sizing Scan the QR...

Page 13: ...13 Installer s Quick Guide aroTHERM plus 11 2020 13 Back to main menu Decide on the installation type On the roof On the wall 300 mm On the ground 100 mm 100 mm Soak away should always be used...

Page 14: ...0027976 Mounting Simple Anti vibration feet large Art No 0020250226 Anti vibration rubber feet small Art No 0020252091 Wall brackets for insulated walls Art No 0020250224 excludes rubber feet Wall bra...

Page 15: ...o 0010027984 excludes rubber feet Connections kits piping and insulation Simple Wall EPP insulation kit Art No 0010027974 includes short straight flexible hose Snow Floor EPP insulation kit Art No 001...

Page 16: ...ump chosen depending on the heating load calculation chosen Installation site planned quiet vented safe System temperatures chosen underfloor radiator fan coil Domestic hot water and buffer tank chose...

Page 17: ...aroTHERM plus 11 2020 17 Back to main menu Scan or click the QR Code to download the aroTHERM plus schematics PDF Choose your system schematic Scan or click QR Code for installation video playlist Wat...

Page 18: ...ack to main menu work your plan Installing the aroTHERM plus system Start with the hydraulic connection Scan or click QR Code for installation video NOTE use of system filter and de airing is importan...

Page 19: ...connection Preparation T20 B A N L PE 30 mm 30 mm 40 mm eBUS 230 V Fuse T4A Power supplyconnection 230 V X211 X210 X200 X206 N L1 N L1 L2 L3 230 V 230 V 1 5 x 5 5 If possible e bus and power cable mu...

Page 20: ...Guide aroTHERM plus 11 2020 20 Back to main menu eBUS connection eBUS X211 X210 X200 X206 N L1 L2 L3 0 6 x 3 5 Fasten cable strain reliefs PH2 Power supply 230 V N L 1 2 3 4 5 1 2 L N L1 L2 L3 N L N X...

Page 21: ...re cylinder with hydraulic components which can easily provide sufficient hot water for the needs of a family of five including the use of rain showers 693 mm 595 mm 1880 mm 70 70 97 103 70 G G 1 G 1...

Page 22: ...bar Art No 0010027981 2x ct optional hydraulic accessories for the uniTOWER Select optional hydraulic System separation uniTOWER heat exchanger module supplied with a single zone pump Art No 001002798...

Page 23: ...mportant note you can use the 18l buffer OR the multizone kits as they fit in the same space at the rear of the uniTOWER Single heating zone Single zone heating with low loss header 1 direct and one m...

Page 24: ...together with a wall mounted hydraulic station and a wide range of accessories including the uniSTOR heat pump cylinders and buffer tanks B B A C D 350 mm 440 mm 720 mm 39 3 47 51 64 5 G 1 143 207 81...

Page 25: ...suitable the heat pump interface must be fitted with all the hydraulic components installed separately A B PE N L 230 V Bus VF1 SP1 PE N L 230 V AF DCF DCF AF ME EVU PE N L MA1 PE N L MA2 PE N Auf Zu...

Page 26: ...de aroTHERM plus 11 2020 26 Back to main menu Connect the system accessories Install the heat exchanger module not for use with uniTOWER 360 500 250 180 180 87 101 40 447 452 40 81 5 81 5 40 20 min 20...

Page 27: ...at pump 1 A B A Installation heating circuit flow B Installation heating circuit flow 500 400 300 200 100 600 700 800 0 B A 500 1000 1500 2000 2500 3000 2 3 1 A Pressure mbar B Flow rate l hour 1 Posi...

Page 28: ...65 939 G 1 2 G 1 G 1 G 1 G 1 G 1 G 1 200 154 100 100 580 120 120 733 631 154 888 467 365 939 G 1 2 G 1 G 1 G 1 G 1 G 1 G 1 200 200 100 10 600 373 Installing the 45 litre buffer tank 888 200 200 100 10...

Page 29: ...29 Installer s Quick Guide aroTHERM plus 11 2020 29 Back to main menu XXXXXXXXX XX XX XXX XXXX 4x G 1 6x 1x 1x G B A D C Flow and return system options 4x G 1 6x 1x 1x G B A D C...

Page 30: ...installation ground wall roof Dirt filter installed in the return Safety valve installed Expansion vessel installed and connected Filling loop and pressure gauge installed All valves installed in syst...

Page 31: ...K to confirm Back OK an an n nts ts ts ts ts ts ts s s nent nent ent ts s s fi s fi fi fi fin finis nis nis shed hed ed d hed hed hed hed firm m Have the installation assistants for all system compone...

Page 32: ...cable communication cable m 50 IP rating IP 15 B Fan power consumption W 40 50 Fan quantity 1 2 Fan air flow maximum m3 h 2 300 5 100 Heating pump power consumption W 2 50 3 87 Heating circuit Heating...

Page 33: ...12102 EN 14511 LWA A7 W45 dB A 53 58 Sound power EN 12102 EN 14511 LWA A7 W55 dB A 54 55 60 Efficiency Energy efficiency class 35 C A to F A Energy efficiency class 55 C A to F A Combination with uni...

Page 34: ...tion kit for ground install extension 0010027972 aroTHERM connection kit for wall install 0010027974 aroTHERM straight pipe connection kit 0010027976 750mm flexihose for air to water heat pump pair 00...

Page 35: ...00 VR 70 VR 91 0020236293 Two wireless heating zones and hot water system VRC 700f VR 70 VR 91f 0020259831 Two wired heating zones and solar thermal hot water system VRC 700 VR 70 VR 11 VR 91 00202598...

Page 36: ...ORT RF VR 71 VR 92f 0010036827 Three wired heating zones and hot water system sensoCOMFORT VR 71 2x VR 92 0010036823 Three wireless heating zones and hot water system sensoCOMFORT RF VR 71 and 2x VR 9...

Page 37: ...Notes...

Page 38: ...Notes...

Page 39: ...Notes...

Page 40: ...es For more information Telephone 0345 601 8885 email training vaillant co uk Dedicated state of the art Centres of Excellence Vaillant has training facilities all over the country Our centres have be...