INSTALLATION INSTRUCTIONS

Optional central heating time clocks for Vaillant Combination boilers:

TURBOmax VUW 242/1 E, VUW 282/1 E

ECOmax VUW 236 E, VUW 286 E

ECOmax 824 E, 828 E

24 hour time clock       Art. No. 300 880

7 day time clock          Art. No. 300 881

NOTE:

This time clock must only be installed by a competent person.

All above listed boilers have a built in frost thermostat. This time clock is not suitable for use with an external frost thermostat.

Summary of Contents for ECOmax VUW 286 E

Page 1: ...W 282 1 E ECOmax VUW 236 E VUW 286 E ECOmax 824 E 828 E 24 hour time clock Art No 300 880 7 day time clock Art No 300 881 NOTE This time clock must only be installed by a competent person All above li...

Page 2: ...1a and pull lower door panel forward and down to release it from the top hinge pin 2 fig 1a Slide the top panel up to release the retaining clips 1 fig 1b Undo screw 1 fig 1c and lower front control p...

Page 3: ...3 and removed Fit the time clock by first passing the connecting lead through the hole left by the time clock blanking plate Insert locating lugs 3 fig 3 into control box and pivot upwards to locate o...

Page 4: ...d as shown in fig 13 Unless already carried out complete the electrical installation by connecting a 230 V 50 Hz electrical supply fused at 3A to the boiler as detailed in the boiler installation inst...

Page 5: ...necting the plug at the socket outlet if there is an isolating switch only remove the fuse from the switch Remove bottom hinge screw 1 fig 1a and pull lower door panel forward and down to release it f...

Page 6: ...me clock by first passing the connecting lead through the hole left by the time clock blanking plate Insert time clock locating lugs 3 fig 7 into control box and pivot upwards to locate onto retaining...

Page 7: ...wire should be removed and the room thermostat connected as shown in fig 13 Unless already carried out complete the electrical installation by connecting a 230 V 50 Hz electrical supply fused at 3A t...

Page 8: ...the mains electricity supply by disconnecting the plug at the socket outlet if there is an isolating switch only remove the fuse from the switch Lower control panel cover Remove screw 1 fig 9a Releas...

Page 9: ...1 fig 10a and lower control box Disconnect HT lead from rear of control box 1 fig 10b Release mains electrical lead from securing clip on rear of control box 2 fig 10b Release control box rear cover r...

Page 10: ...arefully cut a slit in the sealing grommet at the rear of the time clock housing Pass the connecting lead through the grommet Insert time clock locating lugs 3 fig 11 into control box and pivot upward...

Page 11: ...ed and the room thermostat connected as shown in fig 13 Unless already carried out complete the electrical installation by connecting a 230 V 50 Hz electrical supply fused at 3A to the boiler as detai...

Page 12: ...r_ 24h_7d _006 0 Boiler Terminal Strip Refer to boiler installation instructions for full wiring details 4 Connecting a room thermostat 5 Timer operation Note The timer switch contacts are Closed Duri...

Page 13: ...13...

Page 14: ...im en Allemagne Printed on 100 recycled paper Head Office Sales 01634 292310 Vaillant Ltd Vaillant House Service Solutions 0870 6060777 Medway City Estate Trident Close Technical Advice 01634 292392 R...