background image

 

 1 

947753 

 

 

                                                                                                                                                          ISSUE 1

 

 

VIP-148L-IC InformaCast® Compliant 

IP Talkback Horn 

 
 

Installation 

Mounting (Network Interface)

 

The VIP Network Extender is designed for wall 
or shelf mounting and must be within 300 feet of 
the network switch. 
 

Shelf: 

Provided with the VIP Network Extender 

are four rubber pads.  Peel the pads from the 
carrier backing and place at the four corners of 
the bottom of the unit. 

 
Wall: 

Using the hardware provided, secure the 

VIP Network Extender to the wall. 
 

Mounting (Horn) 

The horn should be mounted 15 to 20 feet 
above the floor to allow for best sound 
distribution.  The unit can be mounted to a wall, 
a beam or an electrical box. 

 

NOTE: 

For ease of installation, the base can be 

attached to the speaker before or after the base 
is mounted. 

 

Loosen position adjustment knob 

 

 

Insert the ball of the base into the socket 
of the speaker 

 

 

Tighten the position adjustment knob 

 

 

Mount the base to a wall using the two 
holes provided.  Knockout holes are 
provided for punch out should additional 
holes be desired. 

 

 

A “C” clamp is provided with the horn to 
allow mounting to a beam.  Place the 
bolt through the hole in the bottom of the 
base to secure the “C” clamp to the 
beam.  It is suggested that the horn be 
mounted to the underside of the “I” 
beam to provide maximum positioning 
adjustments. 

 

 

The base has pre-drilled holes for a 
double-gang square electrical box, but 
by drilling out additional knockout holes, 
the base can be mounted to a single-
gang or octagon box 

 
The horn may be rotated or moved up and down 
to obtain the desired position by loosening the 
position adjustment knob at the bottom of the 
unit approximately one turn.  Make required 
adjustments and re-tighten knob. 

 

Reviews: