background image

 

 

VSP-V-1069 

   Issue 

 

1

 947069 

 

 
 

V-1069 

EXPLOSION PROOF TALKBACK HORN 

 
 
 

INTRODUCTION 

The V-1069 is an Explosion Proof Handsfree 
Talkback Horn designed to be used with Valcom 
Handsfree Talkback Control Units features - 
explosion proof construction, metal and 
polycarbonate plastic construction, a wide dispersion 
angle, and an omni-directional mounting bracket and 
may be used for either interior or exterior paging 
applications. 
 
The horn meets or exceeds UL standards for use in 
hazardous areas classified as:   Class I, Groups C & 
D; Gas Atmospheres; Class II, Groups E, F, & G, 
Dust Atmospheres (Metal Carbon or Grain). 
 
The V-1069 has received an FCC type KX 
registration, designed to be used with FCC registered 
Key Telephone Systems.  In accordance with FCC 
rules with applicable tariffs, this Paging Unit may 
only be installed with the authorization of the host 
system.  Installations may be made by Valcom, Inc., 
an authorized agent of the same, equipment 
manufacturers, telephone companies, registered 
telephone refurbishers, and those qualified for 
installation of FCC registered systems under FCC 
Rules Section 68.215.  The FCC Registration 
Number, BAF9I7-69358-KX-N, will be listed in the 
affidavits filed with the telephone company; it will 
also be recorded in the system log kept by installation 
and maintenance personnel.  The local telephone 
company is to be notified of the FCC Registration 
Number when this Paging Unit is installed. 
 

NOMINAL SPECIFICATIONS

 

Frequency 250-12,000Hz 
Dimensions 

8.0” H x 14.6" W  x 17.0" D 

 

(20.32cm H x 37.08cm W x 43.18cm D) 

Dispersion 

120 x 60 

Conduit access 

1/2" 

Weight 

19 lbs. (8.63Kg) 

 

INSTALLATION 

CAUTION:  To prevent ignition of hazardous 
atmosphere, disconnect product from supply circuit

 

       

 

 

before opening.  Keep assembly tightly closed when 
in operation.  Unit must be installed in accordance 
with National Electrical Code requirements for 
hazardous atmospheres.
 
 
Exercise special care in removing back cover of 
explosion-proof driver enclosure to avoid damaging 
machined surfaces.  Prior to re-assembly, make 
certain that joining surfaces of enclosure are free of 
dirt.  Install and tighten all bolts completely.  To 
provide the specified protection in hazardous 
locations, please note that no compound of any type 
is to be applied on machined flange.
 

 
Caution must be exercised in not placing the speaker 
assembly near noise making equipment such as fans, 
transformers, air conditioner units, etc., as this will 
impair the transmission back to the caller. 
 
Mount the horn to a suitable surface 10 to 15 feet 
from the floor taking into account installation and 
maintenance accessibility.  By loosening the two nuts 
which fasten the mounting bracket to the horn, the 
horn may be moved up and down to obtain the 
desired position. 
 
Connect "D" station wire (or other suitable pairs) to 
the proper speaker leads for connection to the audio 
source (tip and ring).  Limit cable runs from Valcom 
Talkback Control Unit to talkback horns to not more 
than 800 feet.

Reviews: