background image

 

 

VSP – One-Way Paging 

  Issue 

14 

 

 

947100 

 

VALCOM ONE-WAY PAGING 

SYSTEM DESIGN/INFORMATION 

 

GENERAL 

These instructions provide the basic information 
required to properly install a One-Way paging system 
manufactured by Valcom, Inc. 
 
Valcom One-Way Paging Equipment may be used with 
any 1A2, Electronic Key, PABX Telephone Systems, 
or with one or more dedicated single line telephone 
sets. 
 

SYSTEM OVERVIEW 

Purpose 

Provides telephone accessed single or multizone 
paging. 
 

Applications 

 

Electronic Key Systems 

 

PABX 

 

Stand alone systems 

 

1A2 

 

 VALCOM
ONE-WAY

CONTROL
    UNIT

 ONE-WAY
 SPEAKER
ASSEMBLY

POWER
SUPPLY

TELEPHONE
   SYSTEM

ONE-WAY PAGING SYSTEM BLOCK DIAGRAM

FIGURE 1

 

Features 

 

1, 3, 6, 9, and 24 (expandable with V-2925A in 24 
zone increments for up to 96) zone page control 
units available. 

 

One-way all call to all speakers available. 

 

Volume controls and amplifiers in each speaker. 

 

No high power amplifier required. 

 

Standard CAT 3, 5, 5E twisted pair cable 
(typically 22 or 24 AWG) is used for speakers. 

 

Existing twisted pair house cables / feed cables 
may be used without introducing crosstalk. 

 

See Multi-Path Information for systems up to 360 
zones. 

 

Access Methods 

 

Electronic Key System line button (C. O. circuit 
required). 

 

PABX loop trunk port (trunk circuit required). 

 

Page port. 

 

Station level access available (with appropriate 
adapter). 

 

Stand alone with dedicated single line sets. 

 

1A2 line button (line card required on most units). 

 
Capacity 

 

All units are one talkpath and one link. 

 

V-1094A, 1 zone (page port access only). 

 

V-2000A, 1 zone with an integrated power supply. 

 

V-2001A, 1 zone with an integrated power supply, 
override capabilities and featuring two integrated 
tone generators for night ringing and time clock 
tones. 

 

V-2003A, 3 zones with all call, background music 
capabilities, override capabilities, two integrated 
tones for night ringing and time clock signaling 
plus integrated power supply. 

 

V-2006A, 6 zones with all call, up to 3 group 
calls, override capabilities, background music 
capabilities, two integrated tone generators for 
night ringing and time clock tones plus integrated 
power supply. 

 

V-2924A, 24 zones with all call, background 
music capabilities. 

 

V-1109RTVA, 9 zones with all call. 

 
Each of the units listed above will drive up to 40 
Valcom one-way amplified speaker assemblies per 
zone (150 on V-1094A, V-9937, V-1101A, V-2000A, 
V-2001A, V-2003A and V-2006A).  Additional 
speakers may be added to a zone by using a V-1094A.  
Each V-1094A allows the addition of 150 more 
amplified speaker assemblies to that zone. 
 

 
 
 
 
 
 
 
 

Summary of Contents for V-1094A

Page 1: ...ectronic Key System line button C O circuit required PABX loop trunk port trunk circuit required Page port Station level access available with appropriate adapter Stand alone with dedicated single lin...

Page 2: ...77cm V 2925A 17 5 H x 8 37 W x 3 06 D 44 45cm x 21 26cm x 7 77cm V 2926 5 3 H x 3 0 W x 1 1 D 13 46cm x 7 620cm x 2 79cm V 2928 5 3 H x 3 0 W x 1 1 D 13 46cm x 7 620cm x 2 79cm V 1109RTVA 7 13 H x 5 9...

Page 3: ...er black vinyl cover V 1016 BK Wall Speaker white vinyl cover V 1016 W 8 Ceiling Speaker V 1020C 8 Ceiling Speaker with knob V 1020KNOB 8 Ceiling Speaker with plastic grille V 1021C Wall Speaker lt br...

Page 4: ...ace speaker and peripheral device has been assigned a Valcom power unit VPU value Products that provide power such as the 2000 Series page control interfaces or power supplies have power unit values i...

Page 5: ...nection to the public telephone network and also carry U L 1459 approval It will ring trip from 70 to 105 VRMS 20 to 30 hertz ringing voltage With a single line telephone the called party provides the...

Page 6: ...ack or mounting frames A 66 type and 25 pair pigtail with female amphenol connector are required for connections to these units if the mounting frames are not used Other control units are wall mount u...

Page 7: ...ipping areas or light manufacturing Noisy 80 90dB This includes machine shops or heavy manufacturing Very Noisy Greater than 90dB This would include areas where talking to another person is very diffi...

Page 8: ...e system plus a preamplifier circuit and in some cases dial select circuitry and or provisions for background music switching Each one way amplified speaker assembly contains a speaker amplifier and v...

Page 9: ...ply is required for V 9934 Up to four v 9934 units may be paralleled on one V 9933A Each V 9934 may be on a 1000 wire run Stacking Feedback Eliminator The V 9964 Stacking Feedback Eliminator is design...

Page 10: ...f 96 zones from a single trunk port Up to 576 Zones with All Call with multiple systems connected for Global All Call Call Valcom Technical Support for assistance Talkback one way or combination syste...

Page 11: ...M 5 V 9915 5 Or V 9915M 5 V 9916 Or V 9916M X X V 1021C V 9918 V 9915 5 V 1021C V 9914 5 V 9915 5 V 9916 X V 1420 V 9816M X The V 9914 5 Bridge and the V 9915 5 Backbox are made of Borg Warner Flamex...

Page 12: ...X X X X Night Ringing Tones X X X Add V 9927A X Time Clock Tones X X X Add V 9927A X Power Supply Built In X X X X X Group Call X X Battery Back up Input X X X X Inhibit Speaker Cancel X X X X Loop St...

Reviews: