background image

V-D11025A / V-D11040A Digital Clocks

Installation and Programming Manual V1.03

Valcom, Inc.
5614 Hollins Road
Roanoke, VA  24019

540-563-2000 P.
540-362-9800 F.
www.valcom.com

Summary of Contents for V-D11025A

Page 1: ...V D11025A V D11040A Digital Clocks Installation and Programming Manual V1 03 Valcom Inc 5614 Hollins Road Roanoke VA 24019 540 563 2000 P 540 362 9800 F www valcom com ...

Page 2: ... Surface Wall Mount Installation 8 Plastic Double Mount Installation 9 Plastic Double Mount Installation 10 Plastic Double Mount Installation 11 Wiring and Jumper Settings 12 V D11025A V D11040A Slave Mode 13 59 Minute Correction 14 58 Minute Correction 14 National Time Rauland 15 Dukane 15 Rauland Digital 16 Midnight Reset or Once a Day Pulse 16 Setting the Time on the Digital Clock 17 Programmin...

Page 3: ... in the kit 3 Disconnect the red filter from the display panel 4 Connect the wiring as shown on the wiring diagram 5 IMPORTANT If using a low voltage system 24 volt make sure that the transformer is an isolated transformer 6 Mount the display panel into the flush mount box using the four 4 black machine screws 6 included in the kit Make sure the switches are on the right side 7 Snap the red filter...

Page 4: ...62 9800 F www valcom com Flush Mount Angled View Front View Side View H 4 65 W 10 3 Flush Mount Picture 2 5 Figure 1 Front view Flush Mount Angled View Front View Side View Flush Mount Picture 4 0 Figure 2 D3 28 D4 3 5 H 4 65 D3 28 D4 3 5 H 7 5 Flush Mount Installation ...

Page 5: ... machine screw nut included in the kit 3 Disconnect the red filter from the display panel 4 Connect the wiring as shown on the wiring diagram 5 IMPORTANT If using a low voltage system 24 volt make sure that the transformer is an isolated transformer 6 Mount the display panel into the flush mount box using four 4 black machine screws 6 included in the kit Make sure the switches are on the right sid...

Page 6: ... mounting rod 7 Insert the support bracket onto the hanger mounting rod 8 Screw the two 2 nuts included in the kit onto hanger mounting rod and secure the clock base to wall 9 Connect the ground wire into the double mount box using the tooth lockwasher and machine screw nut included in the kit 10 Disconnect the red filter from the display panel 11 Connect the wiring as shown on the wiring diagram ...

Page 7: ...7 Valcom Inc 5614 Hollins Road Roanoke VA 24019 540 563 2000 P 540 362 9800 F www valcom com Plastic Surface Wall Mount Installation e w q r t y ...

Page 8: ... and the four holes in the gang box Note If using a metal gang box a ground must be provided to the gang box w Feed Wiring Into the Housing Take the wire coming from the inside of the gang box and feed it through the hole in the middle of the housing e Plug and Secure Wiring Loosen the provided wire clamp comes attached to the inside of the housing and slip excess wiring through and tighten the cl...

Page 9: ...9 Valcom Inc 5614 Hollins Road Roanoke VA 24019 540 563 2000 P 540 362 9800 F www valcom com Plastic Double Mount Installation q t i a y r w w e u o ...

Page 10: ...ounting pole where the wiring will be routed the installer will chose which hole at the end of the pole to use based on how far they want the clock to sit from the wall Screw from the inside of the housing into the four holes surrounding the hole in the center of the housing using the four 4 8 32 x 7 16 screws supplied in the assembly kit 4 screws per clock securing both housings to the mounting p...

Page 11: ...ness and the switch box wires using wire nuts Perform this task for both clocks If using IP clocks wiring will not be supplied with the clocks the installer will be responsible for supplying all Ethernet wiring u Plug and secure wiring Loosen and slip excess wiring through provided wire clamp comes attached to each housing and tighten the clamp After securing excess wiring plug the jack at the end...

Page 12: ...12 Valcom Inc 5614 Hollins Road Roanoke VA 24019 540 563 2000 P 540 362 9800 F www valcom com Wiring Information Wiring and Jumper Settings 220 VAC POWER 220 VAC POWER ...

Page 13: ...13 Valcom Inc 5614 Hollins Road Roanoke VA 24019 540 563 2000 P 540 362 9800 F www valcom com Wiring Information V D11025A V D11040A Slave Mode V CCU ...

Page 14: ...own in the diagram Note Manually set the slave clock to the time from the master clock upon initial connection After the slave clock receives its first daily correction the clocks will be perfectly synchronized 58 Minute Correction Description 110 VAC 24 VAC 60 Hz is used to run the clock normally See digital clock Programming Manual for the four variations of 58 Minute Correction Instructions 1 I...

Page 15: ...cause a daily correction Instructions 1 In programming mode set option 31 to 06 2 Connect interface harness as shown in the diagram Note Manually set the slave clock to the time from the master clock upon initial connection After the slave clock receives its first daily correction the clocks will be perfectly synchronized Dukane Description Applying a 4 10 millisecond pulse on the minute line will...

Page 16: ...te For better synchronization it is recommended to work on a 60 Hz time base Note Use only an isolated transformer to run the clock in 24 volt mode Instructions 1 In programming mode set option 31 to 08 2 Connect the interface harness as shown in the diagram Midnight Reset or Once a Day Pulse Description Applying a minimum of two 2 second pulse will bring the clock to the correct time Note Please ...

Page 17: ...he programming mode by pushing the Set Hour and Set Minute buttons at the same time The AM PM indicator in the upper left corner will start blinking indicating that you are in programming mode Note in order to program these following options option 30 must first be set to E and option 31 must be set to 09 Set Hour Set Minute Option 1 Set Year Use the bottom button to scroll from 00 99 on the displ...

Page 18: ... E the display will switch between showing the time HH MM SS and the date MM DD YY When disabled d the display will show the time only Pressing the Set Minute button allows the user to select between E and d Option 7 American or European Date Style Press the bottom button to scroll between A or E American style shows the month day and year ex 10 28 08 Euro pean style shows day month and the year e...

Page 19: ...ted every 10 seconds 09 Data is transmitted every 10 minutes 04 Data is transmitted every 15 seconds 10 Data is transmitted every 15 minutes 05 Data is transmitted every 30 seconds 11 Data is transmitted every 30 minutes 06 Data is transmitted every minute 12 Data is transmitted every hour Option 12 Set the Time Base Press the bottom button to scroll between q and E This option allows the user to ...

Page 20: ...0 minutes 05 Data is lost after 45 minutes 10 Data is lost after 240 minutes Option 20 Set the Programmable Relay Press the bottom button to scroll between d to 1 9 Please see page 28 to choose the desired setting If option 9 is selected than the user will proceed to option 24 If not then the user will proceed to option 30 Option 21 Once a Day Pulse Output Hours Press the bottom button to scroll b...

Page 21: ...ter an input control mode Option 31 Settings the Auxiliary Input Control Press the bottom button to scroll between 1 9 01 58 Minute Correction 1 06 National Time Rauland 02 58 Minute Correction 2 07 Dukane Digital 03 58 Minute Correction 3 08 Rauland Digital 04 58 Minute Correction 4 09 Once A Day Pulse 05 59 Minute Correction Option 32 Once a Day Pulse Input Hours Press the bottom button to scrol...

Page 22: ...ck to the time Setting the option to E enable will enter option 41 Option 41 Setting the Diagnostic Press the bottom button to scroll between 1 5 and 9 01 Diagnostic 1 04 Diagnostic 4 02 Diagnostic 2 05 Diagnostic 5 03 Diagnostic 3 09 Overrides diagnostic to go to the master clock time Option 42 Duration of time Until the Clock Resumes Normal Operation Press the bottom button to scroll between 00 ...

Page 23: ...o the relay each for one minute on and two minutes off beginning at 5 06 00 4 58th minute 4 The hourly correction for 55 seconds every hour from xx 58 05 to XX 59 00 The daily correction 5 a m 5 p m is 12 correction cycles for 55 seconds The timings will be 05 03 05 05 07 05 05 11 05 05 15 05 05 19 05 05 23 05 05 27 05 05 31 05 05 35 05 05 39 05 05 43 05 and 05 47 05 5 59th minute The hourly corre...

Page 24: ... will also continue sending communication to any clocks down the line that it is connected to How do I take advantage of the V D11025A or V D11040A chronograph functions The Valcom Control Box controls all chronograph functions of the V D11025A or V D11040A The display can be programmed to show either HH MM or MM SS and the readout can count up from 00 00 00 to 99 59 59 or count down with a progra...

Page 25: ...er wires NOTE If you fail to follow instructions b and c listed above the fuses can be blown Clock is only displaying dashes What do I do This means that the clock is receiving power but not receiving a time correction signal a Confirm that the head end is sending data to the clock power supply b Confirm that clock power supply is wired correctly The clock is displaying a time but the colons are f...