background image

© 2005 Directed Electronics, Inc. Vista, CA

N712T  01-05

M

Mooddeell  771122TT

IInnssttaallllaattiioonn  G

Guuiiddee

NOTE:

This product is intended for installation by a professional installer only!

Any attempt to install this product by any person other than a trained professional
may result in severe damage to a vehicle’s electrical system and components.

VVaalleett  

®

®

Summary of Contents for 712T

Page 1: ... al ll la at ti io on n G Gu ui id de e NOTE This product is intended for installation by a professional installer only Any attempt to install this product by any person other than a trained professional may result in severe damage to a vehicle s electrical system and components V Va alle et t ...

Page 2: ...e Recovery System VRS and Warn Away are all Trademarks or Registered Trademarks of Directed Electronics Inc w ww ww w d di ir re ec ct te ec ch hs s c co om m D Di ir re ec ct tF Fa ax x 8 80 00 0 9 99 99 9 1 13 32 29 9 T Te ec ch hn ni ic ca al l S Su up pp po or rt t 8 80 00 0 7 75 53 3 0 08 80 00 0 These resources are for authorized Directed Dealer use only ...

Page 3: ...ur re es s L Le ea ar rn n R Ro ou ut ti in ne e 9 9 S Sy ys st te em m F Fe ea at tu ur re es s M Me en nu us s 1 11 1 F Fe ea at tu ur re e D De es sc cr ri ip pt ti io on ns s 1 11 1 T Tr ra an ns sm mi it tt te er r R Re ec ce ei iv ve er r L Le ea ar rn n R Ro ou ut ti in ne e 1 12 2 T Tr ra an ns sm mi it tt te er r C Co on nf fi ig gu ur ra at ti io on ns s 1 14 4 Standard Configuration 14 ...

Page 4: ...r unlocking the driver s door The BLUE wire outputs a low current pulse on the second press of the unlock button of the trans mitter This negative unlock output is used to unlock the passenger doors RED WHITE OUTPUT OF CHANNEL 2 BROWN BLACK UNLOCK 87A NORMALLY CLOSED ORANGE 500 mA GROUND WHEN ARMED OUTPUT YELLOW SWITCHED IGNITION INPUT ACCESSORY WHITE BLUE 200 mA CHANNEL 3 VALIDITY OUTPUT LT GREEN...

Page 5: ... drawing 30 amps or less It can also drive aftermarket actuators directly Some vehicles require that an aftermarket actuator be added to the driver s door to allow system control see Type D wiring section in Tech Tip Document 1041 H1 6 WHITE BLACK Lock 87 Normally Closed See H1 5 H1 7 VIOLET BLACK Lock 87 Normally Opened Input See H1 5 H1 8 BLUE BLACK Unlock 30 Common Output See H1 5 H1 9 VIOLET U...

Page 6: ...and two pulses when unlocking with the remote This wire will also output pulses for 30 seconds when the Panic Mode is activated If the vehicle has a horn circuit an optional relay can be used to interface with the system as shown below H1 13 LT GREEN BLACK Factory Alarm Disarm This wire supplies a H1 14 WHITE BLUE Channel 3 Output This wire provides a 200 mA output whenever the transmitter code co...

Page 7: ...t This wire supplies a 500mA ground as long as the system is armed This output ceases as soon as the system is disarmed Note If using the H1 16 Orange wire to activate an add on accessory such as window automation pager or voice module a 1 Amp diode must be installed to ensure proper operation Insert the diode as shown the the following diagram H1 17 BROWN BLACK Unlock 87A Normally Closed See H1 5...

Page 8: ...le LED s can be used but they must be wired in series The LED fits into a 9 32 inch mounting hole Be sure to check for clearance prior to drilling the mounting hole NOTE Never use a BLUE LED in combination with a RED LED DIA 41 IMPORTANT Never use this wire to drive anything but a relay or a low current input The transistorized output can only supply 200 mA of current Connecting directly to a sole...

Page 9: ...o os se e Within 10 seconds press and release the Valet Program switch the number of times corresponding to the feature number you want to program See Feature Menus Once the Valet Program switch has been pressed and released the desired number of times press it once more and hold it After a second the LED will flash and the horn will honk to indicate which feature you have accessed 3 T Tr ra an ns...

Page 10: ...ctive arming is now programmed Release the Valet Program switch after the selection has been made You can advance from feature to feature by pressing and releasing the Valet Program switch the number of times necessary to get from the feature you just programmed to the feature you wish to access For example if you just programmed Feature 2 and you next want to program Feature 3 to off release the ...

Page 11: ...ht supervision output H1 4 wire must be connected to an optional relay as described in the Primary Harness Wire Connection Guide 4 DOOR LOCK PULSE DURATION Some European vehicles such as Mercedes Benz and Audi require longer lock and unlock pulses to operate the vacuum pump Programming the system to provide 3 5 second pulses will accommodate the door lock interface in these vehicles The default Fe...

Page 12: ...nput dead bolt systems If programmed ON the door lock output will activate the Comfort Close output for 20 seconds This output will begin 200mS after the final door lock output has completed regardless of the door lock programming If while the 20 second timer is active and closing the windows the user disarms the unit the Comfort Close output will immediately cease before the doors unlock 8 CODE H...

Page 13: ...ures will revert to the default settings This is useful in cases where the one of the customer s transmitters is lost or stolen This will erase any lost or stolen transmitters from the system s memory It can also be used to start from scratch if the trans mitter buttons were programmed incorrectly To exit the learn routine One long horn honk indicates that Learn Routine has been exited Ignition is...

Page 14: ...on transmitter allows arming disarming and Panic Mode activation with separate buttons When programmed for standard configuration using the Channel 1 Auto learn configuration the transmitter buttons are assigned to the following functions operates Arm only operates Disarm only operates Channel 2 and Silent Mode operates Panic only and operate Channel 3 Rapid Resume Logic Rapid Resume Logic ensures...

Page 15: ...light Supervision Relay 87 BROWN Horn Honk Output BLUE 200mA 2nd Unlock Output BLACK Chassis Ground Input RED 12V Constant Power Input WHITE Light Flash Output YELLOW Switched Ignition Input Accessory WHITE BLACK Lock 87 Normally Closed ORANGE 500 mA Ground When Armed Output VIOLET BLACK Lock 87 Normally Open Input BROWN BLACK Unlock 87A Normally Closed BLUE BLACK Unlock 30 Common Output RED WHITE...