The 556CLA Co-Linear adapter is a 

fi

 eld installed kit 

to convert listed direct vent heaters from solid coaxial 

venting to 

fl

 exible 3” side by side co-linear venting 

for installation into existing solid-fuel 

fi

 replaces and 

chimneys. Co-linear piping can only be installed into 

solid-fuel burning 

fi

 replace and chimney cavities.

Have the chimney swept and the 

fi

 replace cavity 

including ash dumps and clean-outs cleaned before 

installing the heater and vent liners. Any creosote or 

soot residue remaining in the 

fi

 replace cavity chimney 

or clean-out may cause odors or stains once the 

heater is installed. Consult with chimney sweep for 

information on how best to clean.

The 556CLA may be 

fi

 tted to the top or rear outlet 

of the 530 and 534 heaters and the rear outlet only 

of the MF28 heater. Co-linear venting is for vertical 

termination only.
An approved co-linear terminal cap is required to 

complete the termination of the co-linear chimney 

system—see allowable venting accessories chart in 

heater installation manual.

Notes:

 

•  Venting limitations and restrictors are as per those 

listed for coaxial venting in the heater installation 

manual, except for the MF24, which uses no restric-

tors when converted to co-linear.

•  Existing gaskets can be re-used if in good condition. 

If not, scrape o

  old gaskets and glue before install-

ing new gasket. DO NOT double-stack gaskets. New 

gaskets can be held in place during assembly by 

using a dab of silicone or white glue (wood / carpen-

ter’s glue).

•  Intake and exhaust liners must correspond between 

heater and roof termination.

•  Ensure liners do not sag and are not crimped when 

installing.

•  Do not bend liners less than 3” radius.

INSTALLATION MANUAL

556CLA

556CLA Co-Linear Adapter

CSA approved for use with Valor 530, 534 and MF28

INSTALLER: Leave this manual with the 

appliance.
CONSUMER: Retain this manual for future 

reference.

WARNING

If the information in these instructions is 

not followed exactly, a 

fi

 re or explosion 

may result causing property damage, 

personal injury or loss of life.

This kit must be installed or serviced by a 

quali

fi

 ed installer, service agency, or gas 

supplier. These instructions are to be used 

in conjunction with the main Installation 

Manual for the heater it is installed on.

Summary of Contents for 556CLA

Page 1: ...in heater installation manual Notes Venting limitations and restrictors are as per those listed for coaxial venting in the heater installation manual except for the MF24 which uses no restric tors when converted to co linear Existing gaskets can be re used if in good condition If not scrape off old gaskets and glue before install ing new gasket DO NOT double stack gaskets New gaskets can be held in...

Page 2: ...dditional screws supplied to seal outer plate to gasketed flange of exhaust spigot 6 Re fit the blank plate 7 Connect 3 dia flex liners directly to their respective outer plate collars using hose clamps included and 2 sheet metal screws per liner to prevent the liners to sllip from the collars 8 Attach the conversion plate This fireplace has been converted label to the existing fireplace using scr...

Page 3: ...ondition or re place with new gasket 5 Re install intake plate using 11 of the 22 screws previously removed on the blank face of the plate Do not screw the face having the inlet hole Ensure that the gasket is in good condition or replace with new gasket 6 Install new outer co linear plate over the top of the intake plate using remaining 11 screws through both plates at the outer perimeter You may ...

Page 4: ...rs sont les mêmes que celles indiquées aux guides d installation des foyers pour une évacuation coax iale à l exception du foyer MF28 pour lequel les re stricteurs d air ne sont pas requise pour l évacuation colinéaire Les joints d étanchéité existants peuvent être utilisés à nouveau s ils sont en bonne condition Sinon grat tez les résidus de joints et la colle avant de poser de nouveaux joints NE...

Page 5: ...future 2 Enlevez la plaque d entrée extérieure Conservez le joint s il est en bonne condition 3 Enlevez la buse d évacuation existante le joint devrait être laissé sur le foyer 4 Installez la buse d évacuation colinéaire en réutil isant les vis enlevées à l étape 3 Assurez vous de bien serrer les vis 5 Installez la plaque colinéaire notez l orientation sur le schéma ci contre en réutilisant les jo...

Page 6: ...s que le joint est en bonne condition ou remplacez le 5 Réinstallez la plaque d évent en L en utilisant 11 des 22 vis retirées précédemment Ne pas vissez le côté ouvert de la plaque Assurez vous que les joints sont en bonne condition ou remplacez les 6 Installez la plaque colinéaire sur le côté ouvert de la plaque en L Vissez la avec la plaque en L sur leur périmètre extérieur à l aide des 11 vis ...

Reviews: