Model
530NG
530LPG
Gas
Natural
Propane
Altitude (Ft.)*
0-4,500 feet*
Input Maximum (Btu/h)
20,500
19,000
Input Minimum (Btu/h)
6,500
12,500
Manifold Pressure (in w.c.)
3.7
10.5
Minimum Supply Pressure
(in w.c.)
5.0
11.0
Maximum Supply Pressure
(in w.c.)
10.5
14.0
Main Burner Injector Marking
580
200
Pilot Injector Marking
35
27
Min. Rate By-Pass Screw
125
125
WARNING
This conversion kit shall be installed by a
qualifi ed service agency in accordance with
the manufacturer’s instructions and all appli-
cable codes and requirements of the authority
having jurisdiction. If the information in these
instructions is not followed exactly, a fi re, ex-
plosion or production of carbon monoxide may
result causing property damage, personal in-
jury or loss of life. The qualifi ed service agency
is responsible for the proper installation of this
kit. The installation is not proper and complete
until the operation of the converted appliance
is checked as specifi ed in the manufacturer’s
instructions supplied with the kit.
Use this manual in conjunction with the instal-
lation manual supplied with the appliance.
P
ORTRAIT
4004066-01
Gas Conversion Kits
530NGK (LPG to NG) / 530PGK (NG to LPG)
Installation Instructions
This appliance is certifi ed for use from 0–4500 feet. For
altitudes above 4500 feet, see local codes.
Kit Contents
1 Pilot injector
1 Burner
1 Main burner elbow injector
1 Set of conversion labels
1 Set of air shutter
Tools Required
• Wrenches to disconnect gas line and 11/16” (17 mm)
and 7/16” (11 mm)
• Phillips (+) screwdriver, to remove burner module
• Small (jewelers size) fl at blade screwdriver, to set
pressure
• Small fl at blade screwdriver, to release pressure tap
on valve
• Needle nose pliers, to remove by-pass screw
• Manometer, to set manifold at the valve
Specifi cations
Use with
Valor Models 530 Heater ONLY
© Copyright Miles Industries Ltd., 2013.