background image

Model

 

530NG

530LPG

Gas

Natural

Propane

Altitude (Ft.)*

0-4,500 feet*

Input Maximum (Btu/h)

20,500

19,000

Input Minimum (Btu/h)

6,500

12,500

Manifold Pressure (in w.c.)

3.7

10.5

Minimum Supply Pressure 
(in w.c.)

5.0

11.0

Maximum Supply Pressure 
(in w.c.)

10.5

14.0

Main Burner Injector Marking

580

200

Pilot Injector Marking

35

27

Min. Rate By-Pass Screw

125

125

WARNING

This conversion kit shall be installed by a 
qualifi ed service agency in accordance with 
the manufacturer’s instructions and all appli-
cable codes and requirements of the authority 
having jurisdiction. If the information in these 
instructions is not followed exactly, a fi re, ex-
plosion or production of carbon monoxide may 
result causing property damage, personal in-
jury or loss of life. The qualifi ed service agency 
is responsible for the proper installation of this 
kit. The installation is not proper and complete 
until the operation of the converted appliance 
is checked as specifi ed in the manufacturer’s 
instructions supplied with the kit.

Use this manual in conjunction with the instal-
lation manual supplied with the appliance.

P

ORTRAIT

4004066-01

Gas Conversion Kits

530NGK (LPG to NG) / 530PGK (NG to LPG)

Installation Instructions

This appliance is certifi ed for use from 0–4500 feet. For 
altitudes above 4500 feet, see local codes.

Kit Contents

1 Pilot injector
1 Burner
1 Main burner elbow injector
1 Set of conversion labels
1 Set of air shutter

Tools Required

•  Wrenches to disconnect gas line and 11/16” (17 mm) 

and 7/16” (11 mm)

•  Phillips (+) screwdriver, to remove burner module
•  Small (jewelers size) fl at blade screwdriver, to set 

pressure

• Small fl at blade screwdriver, to release pressure tap 

on valve

•  Needle nose pliers, to remove by-pass screw
•  Manometer, to set manifold at the valve

Specifi cations

Use with 

Valor Models 530 Heater ONLY

© Copyright Miles Industries Ltd., 2013.