background image



          

 

       

 

   

  

    ADCA                         

 

VAL

S

TEAM

 

ADCA

                     

We reserve the right to change the design and material of this product without notice.

 

 

 

IMI 1.533 E 02.17 

 

INSTALLATION AND MAINTENANCE INSTRUCTIONS 

BALANCED PRESSURE THERMOSTATIC CLEAN STEAM TRAPS 

TSS 7 

– TSS 6  

 

GENERAL 
 

 

These  instructions  must  be  carefully  read  before  any  work  involving  products  supplied  by  VALSTEAM  ADCA 
ENGINEERING S.A. is undertaken. 

 

 

The installation procedure is a critical stage in a life of a steam trap and care should be taken to avoid damage 
to the trap or equipment. 

 

 

The TSS 7 and TSS 6 steam traps are specially designed to remove air and condensate from clean and pure 
steam  systems.  They  give  their  maximum  performance  only  when  the  equipment  associated  with  them  is 
correctly sized and installed in accordance with our recommendations. 

 
Note: 
 

 

Current  regional  safety  regulations  should  be  take  in  to account and  followed,  while  doing  the  installation  and 
maintenance work. 

 

Handling, installation and maintenance work must be carried out by trained personnel. A supervisor must follow 
and check all activities. 

 

For the problems that cannot be solve with the help of this instructions, please contact the supplier or the 
manufacturer. 

 

The manufacturer reserves the right to change the design and material of this product without notice. 

 

 

 

 

If malfunction of any other equipment or system operation failure may result in a dangerous overpressure, over 
temperature or even vacuum condition, a safety device must be included in the system to prevent such 
situations. 

At start up, the presence of small particles in the fluid (dirt, scale, weld splatters, etc) may cause an imperfect 
closure of the seat. If this occurs, proceed to an accurate cleaning. 

Do  not  touch  the  equipment  without  appropriate  protection  during  working  operation  because  it  may  conduct 
heat if the used fluid is at high temperature. 

Before  starting  maintenance  be  sure  that  the  equipment  is  not  pressurized  or  hot.  Even  if  upstream  and 
downstream isolating valves have been closed care should be taken since fluid under pressure may be trapped 
between them. 

Before removing the cover of the equipment make sure that its temperature has decreased to ambient 
levels, otherwise damage of the thermostatic element may occur, due to thermal chock. 

The equipments must be used within the working temperature and pressure limits laid down for them, otherwise 
they may fail (refer to nameplate and/or IS- Information Sheet). 

Manual  handling  of  products  may  present  a  risk  of  injury.  You  are  advised  to  assess  the  risks  taking  into 
account the task, the individual, the load and the working environment.  

Before starting work ensure that you have suitable tools and/or consumables available. Use only genuine ADCA 
replacement parts. 

Do  not  remove  the  nameplate  attached  to  the  equipment.  Serial  number  and  other  useful  information  is 
stamped on it. 

During the assembly work, apply protective measures against dirt. 

The equipment should be carefully handled, to prevent any damage on the machined surfaces. 

Correct installation of the equipment is full responsibility of the contractor. 

Steam traps are designed to be applied in places protected from exposure to weather. 

We  recommend  special  constructions  or  protective  measures  for  applications  on  the  outside  or  in  adverse 
environments like corrosion-promoting conditions (sea water, chemical vapors, etc). 

 

Summary of Contents for TSS 7

Page 1: ...cale weld splatters etc may cause an imperfect closure of the seat If this occurs proceed to an accurate cleaning Do not touch the equipment without appropriate protection during working operation because it may conduct heat if the used fluid is at high temperature Before starting maintenance be sure that the equipment is not pressurized or hot Even if upstream and downstream isolating valves have...

Page 2: ...e and removing operations In order to allow installation and maintenance work without emptying the system stop valves should be installed upstream and downstream of the steam trap If the system cannot be stopped for maintenance it is recommended that isolating valves are installed upstream and downstream of the steam trap together with a by pass manual regulating valve The process can be then cont...

Page 3: ... an imperfect closure of the seat If this occurs proceed to an accurate cleaning Periodical checking 24 hours after the start up it is recommended to check pipe connections for leaks and retighten the connections if necessary MAINTENANCE We recommend the steam traps to be serviced as necessary Steam traps should be checked periodically at least yearly to verify if they are operating correctly and ...

Page 4: ...roceed to an accurate clean and identify the possible reason of contamination SPARE PARTS PRODUCTS RETURNING Information regarding any hazards and precautions to be considered because of contaminating fluids and residues or mechanical damage that may represent a health safety or environmental risk must be provided in writing by the distributors and costumers when returning products to Valsteam ADC...