background image

 

 

PRODUCT MANUAL 

Diver Smart Interface Cable – AS346 

Summary of Contents for AS346

Page 1: ...PRODUCT MANUAL Diver Smart Interface Cable AS346 ...

Page 2: ...ll not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material In no event shall Van Essen Instruments B V be liable for any claim for direct incidental or consequential damages arising out of or in connection with the sale manufacture delivery or use of any product Van Essen Instruments and the Van Esse...

Page 3: ... directive as amended by EN61326 1 2013 The product s to which this declaration relates is in conformity with the essential protection requirements of 2014 30 EU Electromagnetic Compatibility directive The products are in conformity with the following standards and or other normative documents EMC Harmonized Standards EN 61326 1 2013 Lab Equipment EMC IEC61000 6 3 2007 Emission standard for reside...

Page 4: ...ted 3 2 1 Supported Equipment 3 2 2 Software 4 2 3 Connecting the Smart Interface Cable 4 2 4 LED Indicators 4 2 5 Reading Atmospheric Pressure 5 3 Appendix A Specifications 8 4 Appendix B Diver Equipment 9 4 1 Diver Office software 9 4 2 USB Reading Unit 9 4 3 Communication Cable 9 4 4 TD Diver 10 4 5 Baro Diver 10 4 6 Cera Diver 11 4 7 Micro Diver 11 4 8 CTD Diver 12 ...

Page 5: ...art Interface Cable AS346 including the DDC DXT Adapter AS348 and Suspension Plate MB43191 The Smart Interface Cable features a barometric pressure sensor that allows for real time comparison of Diver readings and manual measurements The Smart Interface Cable also features indicators for sensing if a communication cable is connected a Diver is connected to the cable or if the communication cable i...

Page 6: ...Informational indicators ready sending data receiving data Warning indicators Diver not connected communicating cable malfunctioning This manual outlines all the features and operating principles of the Smart Interface Cable The next chapter gives an overview of the supported equipment installation procedures and configuration 1 2 Specifications The specifications of the Smart Interface Cable are ...

Page 7: ...8 Figure 3 Smart Interface Cable connected to left a DXT cable and right a Diver Data Cable through the DDC DXT Adapter AS348 2 Getting Started 2 1 Supported Equipment The following Divers can be used in combination with the Smart Interface Cable TD and Baro Diver model DI8xx Mini and Baro Diver model DI5xx Micro Diver model DI6xx Cera Diver model DI7xx CTD Diver model DI27x and MTD Diver model DI...

Page 8: ... the Suspension Plate MB43191 on the M12 connector of the Smart Interface Cable then connect it to the DXT Cable see Figure 4 This ensures that the Diver returns to the same position in the well while connected to the Smart Interface Cable Figure 4 The Smart Interface Cable with the Suspension Plate snapped on connected to a DXT Cable left before read out and right in position to read real time Di...

Page 9: ...hen the communication is finished the green LED will remain off for approximately 5 seconds before being turned on again The red LED indicates when an issue arises There are two modes The red LED is continuously on o No communication cable is connected o There is an issue with the communication cable for example the communication cable is broken The red LED is blinking The Diver could not be detec...

Page 10: ...d the window as shown in Figure 7 will appear The Barometric Pressure value is automatically populated The Calculated Cable Length value is automatically retrieved from the database if present or can be entered manually Enter a Manual Measurement to calculate the Difference between Diver and Manual Measurement or if the cable length is unknown click the Recalculate button to determine the Calculat...

Page 11: ... March 2018 Van Essen Instruments All rights reserved www vanessen com 7 Figure 7 Real Time Data window with the atmospheric pressure reading from the Smart Interface Cable ...

Page 12: ...ble AS6xxx through DDC DXT Adapter AS348 Supported DXT DDC cable length 1 to 500 m Compatible Diver models TD Diver DI8xx Micro Diver DI6xx Cera Diver DI7xx CTD Diver DI27x MTD Diver DI24x Mini Diver DI5xx 3 1 3 Software Diver Office 2017 2 or later must be installed to be able to communicate with the Smart Interface cable 3 1 4 Barometric Pressure Sensor Range 400 to 1100 cmH2O Accuracy 2 0 cmH2O...

Page 13: ... www vanessen com 4 2 USB Reading Unit The Diver USB Reader can be used for programming or reading the Diver Connect the USB Reader to the USB port of your PC or Laptop Simply insert the Diver into the base of the USB Reading Unit and you are ready to communicate with your Diver The USB Reading Unit can be used in the field or the office Part no AS330 4 3 Communication Cable Deploying a Diver on a...

Page 14: ...llowing pressure ranges 10 m 20 m 50 m and 100 m Part no DI8xx 4 5 Baro Diver The Baro Diver is manufactured using a stainless steel 316 L casing with a 22 mm diameter The Baro Diver can store a maximum of 72 000 measurements date time pressure and temperature in its working memory and 72 000 measurements in its backup memory The Baro Diver measures atmospheric pressure and is used to compensate f...

Page 15: ... The Cera Diver is available in the following pressure ranges 10 m 20 m 50 m and 100 m Part no DI7xx 4 7 Micro Diver The Micro Diver is the smallest Diver measuring only 18 mm in diameter It is specifically designed for monitoring wells or drive points too small to accommodate larger dataloggers This Diver is suitable for pipes with a diameter of at least 20 mm The Micro Diver has a stainless stee...

Page 16: ...e housing is the instrument of choice The CTD Diver is equipped with a four electrode conductivity sensor that measures electrical conductivity from 0 to 120 mS cm There are two options for measuring conductivity true or specific conductivity at 25 C The CTD Diver can store 48 000 measurements date time pressure temperature and conductivity The CTD Diver has the following sample methods fixed even...