* Operation.

The 

ALFA(NET) 804-ADS

 is drying timer unit for water containing coatings, the water in these coatings

must be evaporated by the ADS-unit (Aqua Dry System) thru a extra drying in between two spraying
sessions . The 

ALFA(NET) 804-ADS

 can evaporate at two different ways; 

The first method is drying direct with a drying-time T1 (0..60 minutes) and 
The second method is to wait first a delay time T0 (0..30 minutes) and than dry with a drying-time 
T2 (0..60 minutes).

* Installation.

On the topside of the 

ALFA(NET) 804-ADS

 can be read how to connect this unit, such as power

supply, relay-output, contact-input and network.
After power up the 

ALFA(NET) 804-ADS

 and the self test is finished the unit displays the set drying

time T1 in it’s display.

* Control.

The 

ALFA(NET) 804-ADS

 timer-unit can by controlled by three push bottons on the front. These keys

are: 

SET [

5

]

- view / change setting.

UP

[

]

- starts the timer / increase setting.

DOWN [

]

- stops the timer / decrease setting.

* Viewing the time-settings of the timer.

First press the 

SET

 key and than press the 

UP

 and/or 

DOWN

 keys to show the next timer settings on

the display. To indicate which timer setting is shown a LED is blinking as follows;
T0:

The delay time is shown in the display as the upper left LED is blinking.

T1:

The direct-drying time is shown in the display as the LED ‘set’ is blinking.

T2:

The drying-time after delay is shown in the display as both LED’s are blinking.

A few seconds after releasing the keys the timer-unit returns to it’s normal operation.

* Changing the time-settings of the timer.

First press the 

SET

 key and choose one of the time-settings as above with the 

UP

 and/or 

DOWN

 keys. 

To change the chosen  time-setting while displayed, first press the 

SET

 key again and hold it while

pressing the 

UP

 and/or 

DOWN

 keys  to change it’s setting. A few seconds after releasing the keys the

timer-unit returns to it’s normal operation, with the new setting.

1

Summary of Contents for ALFA 804-ADS

Page 1: ...S timer unit can by controlled by three push bottons on the front These keys are SET 5 view change setting UP starts the timer increase setting DOWN stops the timer decrease setting Viewing the time settings of the timer First press the SET key and than press the UP and or DOWN keys to show the next timer settings on the display To indicate which timer setting is shown a LED is blinking as follows...

Page 2: ...maining drying time is frozen To end this hold situation the UP key must be pressed But if the DOWN key is pressed for the second time than the drying time is stopped directly the display shows for 5 seconds 000 and the ON LED deactivates The timer is stopped completely and after the 5 seconds the display shows the set direct drying time T1 again The time is now ready for the next start Setting de...

Page 3: ...ber x 1000 Seriel number units 1 250 00 99 1 52 0 250 0 9991 Remark In case that the timer unit is set on minutes P01 0 the display shows the last minute of the current rest time in seconds To indicate this the lower segment of the first digit is lit and the other digits show the time in seconds Error messages In the display of the ALFA NET 804 ADS the following error message can appear EE Setting...

Page 4: ... are available upon request Dimensions Connections Adress VDH Products BV Tel 31 0 50 30 28 900 Produktieweg 1 Fax 31 0 50 30 28 980 9301 ZR Roden Email info vdhproducts nl The Netherlands Internet www vdhproducts nl 4 ...

Reviews: