background image

VDO Kienzle Vertrieb und Service GmbH

Montage- und Bedienungsanleitung

Installation and Operating Instructions

Wind

olwind~1.qxd  09.11.99 08:34  Seite 1

Summary of Contents for WIND

Page 1: ...VDO Kienzle Vertrieb und Service GmbH Montage und Bedienungsanleitung Installation and Operating Instructions Wind...

Page 2: ...Installation and Operating Instructions Page 22 40 21...

Page 3: ...22...

Page 4: ...tenance of the VDO Ocean Line Wind 30 Troubleshooting 30 Installing the VDO Ocean Line Wind 31 Installing the indicating instrument 31 Installing the wind sensor 33 Electrical installation 36 Setting...

Page 5: ...patched in excellent condition Please take the time to study this manual carefully It will tell you all you need to know about the functions of your VDO anemometer system and ensure that it is straigh...

Page 6: ...metallic or electrically conducting jewelry such as chains bracelets rings etc when working on the on board electrical system Disconnect the minus polarity of the battery before starting your work to...

Page 7: ...onducting parts of the connected consumers are protected against direct contact The use of non insulated wires and contacts is strictly forbidden Safety Instructions for maintenance Anemometer system...

Page 8: ...dial The apparent wind speed is shown on the LCD A maximum of 3 additional subsidiary indicating instruments can be connected to the indicating instrument for example a wind speed indicating instrume...

Page 9: ...ain relief for mast cable Connecting socket Product certificate Installation and operating instructions Accessories must be ordered separately Fixation kit bracket N05 800 792 Lighting kit 24 V 1 2 W...

Page 10: ...Apparent wind speed The wind speed is shown on the LCD in the unit specified during setup m s km h bft or kts The selected unit will be marked on the display with a small angle in the above illustrati...

Page 11: ...ting Fault Cause Remedy VDO Ocean Line Wind Check electrical connections are without function accordance with the wiring in diagram Check the on board voltage supply voltage is 10 8 to 32 V DC Check c...

Page 12: ...ace the supplied black rubber washer on the instrument back Connect the cables per wiring schematic to the indicating instrument and insert the instrument into the mounting hole see Electrical install...

Page 13: ...1 5 Nm max 1 5 Nm max 32 Screw threaded stud in here Screw threaded stud in here Fixation parts kit N05 800 792 order separately INSTALLATION...

Page 14: ...g direction should be pointing ahead 0 if possible If this is not possible other mounting directions can be used 90 180 270 In this case the vane must be dismantled by loosening the screw Mount the va...

Page 15: ...ship axis or to port or starboard Inclinations of the mast top can be compensated with the sensor footplate Lateral mast mounting of the sensor is also possible Install the sensor on the base plate Se...

Page 16: ...the other end of the mast cable from the indicating instrument to the connecting socket at the foot of the mast Installing the connecting socket Install the cable socket below deck at the foot of the...

Page 17: ...h off the power supply before this time elapses and switch it on again The black needle on the instrument now points to the other units for the wind speed in turn in a clockwise direction When it reac...

Page 18: ...System power supply 37 INSTALLATION F 1 F 2 S 1 S 2 1 2 3 5 8 Illumination 4 Key for the circuit diagram appears on page 41 Connecting cable wind sensor...

Page 19: ...eed indicating instrument as the main indicating instrument see page 11 The maximum length of the cable between the main indicating instrument and the wind speed indicating instrument is 10 m The powe...

Page 20: ...ATION The main indicating instrument should be connected to the wind speed indicating instrument as shown below Main indicating instrument or secondary indicating instrument Wind speed indicating inst...

Page 21: ...indicating instruments must be switched on at the same time The main and secondary indicating instruments should be connected as shown below Up to 3 subsidiary indicating instru ments can be connected...

Page 22: ...inductive transmission Cup anemo meter with Hall chip Accuracy direction 3 speed 2 km h 0 60 km h Resolution Direction 1 Speed 1 km h Supply voltage 10 8 to 30 V DC Current consumption about 140 mA a...

Page 23: ...209 06 99 Wind VDO Kienzle Vertrieb und Service GmbH Kruppstrasse 105 D 60388 Frankfurt am Main Tel 49 0 69 40805 0 Fax 49 0 69 40805 177 e mail vdomarine vdokienzle com Internet www vdokienzle com m...

Reviews: