X2-OPERATING MANUAL 

 WITH TOUCH SCREEN

 

 

Doc: 70-00-0741, Serie X2, 20190213 

© Vector Controls GmbH, Schweiz 

Page 1 

subjects to alteration 

www.vectorcontrols.com 

V

ECTOR

 

 

Operating instructions Touch devices of 

the X2 operating system 

The X2 operating system was designed for universal controllers and sensors. Devices based on the X2 

operating system contain a multitude of standardized functions and application possibilities. From simple 

ventilation controllers for domestic applications to HVAC system solutions for entire buildings. There is a 

suitable solution for almost every application. With the EasySet program, the controllers can be 

conveniently read out, programmed and transferred to other controllers. 

Applications 

These operating instructions apply to devices of the X2-series devices using the OPT1 series touch panel HMIs. The 

FC

 

series is suitable for the Feller EDIZIOdue® frame. 

Summary of Contents for OPT1-FC-HTNV-VC

Page 1: ...contain a multitude of standardized functions and application possibilities From simple ventilation controllers for domestic applications to HVAC system solutions for entire buildings There is a suita...

Page 2: ...ve input and a voltage input packed with AMM AD W OPT1 FU TNV VC 40 500116 Remote operation terminal with an internal temperature sensor a passive input and a voltage input packed with AMM UD W OPT1 F...

Page 3: ...ons according to setpoint Unoccupied Standby Economy Setpoint and power reduced OFF Energy hold OFF EHO All outputs switched off inputs for alarms monitored Heating active Cooling active Fan active Ma...

Page 4: ...a pending delay For example if a start up delay is active The controller remains switched off and displays the hand symbol until the delay has elapsed Then the controller switches on and the hand symb...

Page 5: ...48 hours The time must be set for the schedules to work The summer winter time changeover can be activated by the technician via user parameters 1 Setting the Time 1 1 Press CLOCK button longer than...

Page 6: ...1 Pr01 is selected 1 bar indicates that step 1 is complete Press the RIGHT button to set the desired time This is done using the UP and DOWN buttons from 00 00 23 45 2 bars indicate that step 2 is co...

Page 7: ...button to complete the selection 1 bar indicates that step 1 is completed 2 Selection of the first month of the holiday schedule Select the first month of the holiday schedule where 1 stands for Janu...

Page 8: ...2 Cooling with fan The controller is in fan only mode The fan is controlled according to the controller specification or setpoint The mechanical cooling is deactivated or is not switched to it Option...

Page 9: ...ated on the second image or Pressing the LEFT button takes you to the higher level Here you have the possibility to select the different inputs and outputs The displayed values are not adjustable in t...

Page 10: ...Schweiz Page 10 subjects to alteration www vectorcontrols com VECTOR Efficient use of energy for a better future Quality Innovation Partnership Vector Controls GmbH Poststrasse 20 CH 8620 Wetzikon Sch...

Reviews: