PEM30DN
- 1 -
VELLEMAN
PEM30DN - PHOTOELECTRIC SENSOR (THROUGH BEAM)
1. Introduction
To all residents of the European Union
Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm
the environment.
Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized
company for recycling.
This device should be returned to your distributor or to a local recycling service.
Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
2. Features
•
universal AC/DC input voltage
•
IP-66 waterproof
•
N.O. output
•
6ft of cable wire
•
mounting brackets/screws included
3. Specifications
Detection type
through beam
Sensing range
max. 30m
Input voltage
12-240Vdc ± 10% or 24-240Vac ± 10%
Response time
15ms
Emitting element
IR LED
Operation indicator
yellow LED (lit when beam is broken)
Current consumption
2VA max.
Output method
relay output
Contact current
3A / 250Vac
Illumination
lamplight<10000Lux ; sunlight <30000Lux
Connection method
cable lead wires: brown/blue/white/black/grey
Noise resistance
1500Vp-p/1µ s
Surge resistance
2kV/1µ s
Vibration resistance
10-55Hz / 1.5mm, 2 hours in X.Y.Z.-phase
Housing material
case: intensive ABS ; lens: PC
Operating temperature
-20 ~ +60°C
Waterproof
IP-66
Safety standard
CE
3. Wiring Diagram = Bedrading = Câblage = Verkabelung = Cableado
brown = bruin = brun = braun = marrón
→
blue = blauw = bleu = blau = azul
→
black = zwart = noir = schwarz = negro
→
NO
white = wit = blanc = weiß = blanco
→
COM
grey = grijs = gris = grau = gris
→
NC
The black, white and grey cables are only available on the receiver.
supply voltage = voedingsspanning =
tension d'alimentation = Spannungsversorgung =
tensión de alimentación = 12-240Vdc/cc ± 10%
or/of/ou/oder/o 24-240Vac/ca ± 10%