Chronothermostat

IRIDE

User Manual

Summary of Contents for Iride

Page 1: ...Chronothermostat IRIDE User Manual...

Page 2: ......

Page 3: ...fication Page 23 Temperatures T1 T2 T3 modification Page 24 Timing setting Page 26 Advanced functions menu Page 27 Manual operation Page 30 Off operation Page 31 Backlighting management Page 33 Minimu...

Page 4: ...al input for the connection of a telephone dialler for switches on and switches off of the device remotely Summer and winter operating mode Front panels of white and anthracite grey colour included in...

Page 5: ...ONNECTION DIAGRAM Chronothermostat frames and plastic elements available in white and anthracite grey colors frames mount A mount B plastic elements VI plastic elements BM COM NA NC N L 230V Iride 230...

Page 6: ...4 Iride Chronothermostat User Manual BATTERY IRIDE MOUNTING A Bticino Living series Light Light Tech Livinglight Axolute Vimar Eikon series Eikon Evo Plana Ave S44 series ABB Mylos series English...

Page 7: ...5 Iride Chronothermostat User Manual IRIDE 230 MOUNTING Bticino Living series Light Light Tech Livinglight Axolute Vimar Eikon series Eikon Evo Plana Ave S44 series ABB Mylos series A English...

Page 8: ...6 Iride Chronothermostat User Manual BATTERY IRIDE MOUNTING ABB Chiara series Vimar Ark series B English...

Page 9: ...7 Iride Chronothermostat User Manual IRIDE 230 MOUNTING ABB Chiara series Vimar Ark series B English...

Page 10: ...8 Iride Chronothermostat User Manual BATTERY IRIDE MOUNTING Gewiss Chorus series B Remove the cogs English...

Page 11: ...9 Iride Chronothermostat User Manual IRIDE 230 MOUNTING Gewiss Chorus series B Remove the cogs English...

Page 12: ...10 Iride Chronothermostat User Manual BATTERY IRIDE MOUNTING Bticino Matix series B BM Remove the cogs English...

Page 13: ...11 Iride Chronothermostat User Manual IRIDE 230 MOUNTING Bticino Matix series B BM Remove the cogs English...

Page 14: ...12 Iride Chronothermostat User Manual BATTERY IRIDE MOUNTING Vimar Idea series VI B English...

Page 15: ...13 Iride Chronothermostat User Manual IRIDE 230 MOUNTING Vimar Idea series VI B English...

Page 16: ...al BATTERY IRIDE MOUNTING Bticino Livinglight AIR series AIR Note if the box extension is not present adapter which increases the depth of the flush mounting box we recommend you using the frame for L...

Page 17: ...nual IRIDE 230 MOUNTING Bticino Livinglight AIR series AIR Note if the box extension is not present adapter which increases the depth of the flush mounting box we recommend you using the frame for Liv...

Page 18: ...16 Iride Chronothermostat User Manual BATTERY IRIDE MOUNTING Bticino Livinglight AIR series AXO AIR Mount AXO AIR is not included in the package English...

Page 19: ...17 Iride Chronothermostat User Manual IRIDE 230 MOUNTING Bticino Livinglight AIR series AXO AIR Mount AXO AIR is not included in the package English...

Page 20: ...protection device from the overcurrents must be present for Iride 230 models only Code Model Description VE456000 Iride Touch screen chronothermostat batteries VE457800 Iride 230 Touch screen chronoth...

Page 21: ...or power supply Temperature regulation On off with hysteresis setting between 0 1 C and 1 C Proportional with settable band and period Summer winter operating mode Weekly programming 7 programs availa...

Page 22: ...ogramming menu not used not used Time and minutes Load activation in summer mode cooling Manual operation activation Load activation in winter mode heating Measured environment temperature Program on...

Page 23: ...display To clean the display use a soft lint free cloth without using excess force INSTALLATION The chronothermostats of Iride series are designed for flush mountig on 3 modules box 503 type The chron...

Page 24: ...setting Day setting the diagram adjustable cover plates and they are mount A mount B according to the needs it could be necessary to remove the side cogs mount AIR couple of side BM plastic elements...

Page 25: ...the graphic of the program on Attention To operate correctly the chronothermostat requires the time and date insertion If once mains powered no value is set within about 30 seconds the chronothermost...

Page 26: ...arts flashing Parameters sequence to set is seconds minutes hours year month day 3 Use the keys and to modify the values and the key to confirm moving to the next parameter for seconds it s possible o...

Page 27: ...ntil the symbol flashes and press the key to access the parameters modification 3 The programs page is displayed the first day of the week DAY 1 flashing the current program for example P1 of the curr...

Page 28: ...and the delay and press the key to move to the next hour 4 When the program satisfies the user s needs go back to the days pressing twice the key and repeat for the other days of the week the operatio...

Page 29: ...The value of the flashing T3 temperature is displayed Modify the value with the key and and press the key to go back to the page of T1 temperature 6 Once all parameters are set to exit and to go back...

Page 30: ...e measurement unit change hours and days 4 The measurement unit starts flashing h0ur or day Press the keys and to choose a timing in hours h0ur or days day Timing setting This menu allows the setting...

Page 31: ...following operation parameters operating mode heating or cooling regulation type on off or proportional parameters relative to regulation type antifreeze temperature password for key lock system oper...

Page 32: ...ating and summer cooling For further information about the operating mode see the chapter Regulation type on page 36 Regulation type only for heating mode For heating mode it s possible to choose betw...

Page 33: ...it s possible to set a safety temperature antifreeze temperature 0ff to maintain also if the chronothermostat is switched off It s possible to choose a value between 1 C and 10 C It s also possible to...

Page 34: ...tion the chronothermostat performs as a normal thermostat adjusting on the basis of the Tm temperature manual setpoint independently from the day and the time where it is The manual operation is signa...

Page 35: ...maintains a minimum temperature Toff antifreeze temperature to avoid the freezing of the systems where the device is installed Toff can have values between 1 C and 10 C or it can be completely shut d...

Page 36: ...mal operation according to the set programming closed chronothermostat in off mode Remotely off status is displayed with the flash of the symbol on field 9 to differentiate it from the keyboard off st...

Page 37: ...es following the difference between the measured temperature and the programmed setpoint In particular it will be blue if the measured temperature is lower than the programmed setpoint of at least 0 5...

Page 38: ...cks during the summer period in order to prolong the lighting time in the late afternoon to the loss of the early morning In European countries summer time starts the last Sunday of march and ends the...

Page 39: ...is displayed indicated with the symbol In the example a the Sunday 7 of the last week LA of march 03 at 2 o clock 02 b if it s necessary change the parameters with the keys and and move to the next p...

Page 40: ...increasing heating mode cooling mode where SET represents the setpoint and DIFF the hysteresis useful to avoid continuous switches on switches off dangerous for the system in proximity to the reaching...

Page 41: ...tion period is passed the device compares again the environment temperature with the setpoint and it updates the activation and deactivation times for the new period The result of the proportional reg...

Page 42: ...end of the timing operation will then switched to automatic mode Emergency regulation winter mode only The device performs a regulation of emergency if an error occurs during the reading of the probe...

Page 43: ...ted in minutes and for this reason if for example you set a timing of 3 days at 12 15 on Tuesday it will expire at 12 15 on Friday Attention the timings can end before their programmed expiration if o...

Page 44: ...ate and time the performed programmings on the contrary remain memorized even if this limit is surpassed Attention after batteries replacement the display will switch on within 15 seconds at max Dispo...

Page 45: ...de Chronothermostat User Manual REFERENCE STANDARDS Compliance with Community Directives 2014 35 EU LVD 2014 30 EU EMCD is declared in reference to the harmonized standards EN 60730 2 7 EN 60730 2 9 E...

Page 46: ...0 C 0 1 C 25 0 C antifreeze temperature 1 0 C 10 0 C 0 1 C 6 0 C operating mode winter summer winter regulation type ON OFF PROP ON OFF ON OFF hysteresis 0 1 C 1 0 C 0 1 C 0 3 C proportional band 0 5...

Page 47: ...19 20 21 22 23 P3 T3 T2 T1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P4 T3 T2 T1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P5 T3 T2 T1 0 1 2 3 4 5 6 7 8 9 10 1...

Page 48: ...19 20 21 22 23 P3 T3 T2 T1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P4 T3 T2 T1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P5 T3 T2 T1 0 1 2 3 4 5 6 7 8 9 10 1...

Page 49: ......

Page 50: ......

Page 51: ......

Page 52: ...V3IS00684 014 Vemer S p A I 32032 Feltre BL Via Camp Lonc 16 Tel 39 0439 80638 Fax 39 0439 80619 e mail info vemer it web site www vemer it 06 2017...