background image

Installation Instructions

     

Specifications are subject to change without notice. 

Page 1

enquiry@manrose.co.nz | www.manrose.co.nz 

Distributed by Simx Limited

 

MultiVent Continuous Extract Ventilation

Thank you for purchasing this quality MultiVent continuous extract ventilation system.

To ensure correct function and safety, please read all instructions before using the product and keep all instructions for future reference. 

Description

Product Code

MultiVent Continuous Extract Ventilation System 

FAN7200

When using electrical appliances, basic safety precautions should always 
be followed to reduce the risk of fire, electrical shock and personal injury.

A

B

C

D

E

F

362

391

111

248

165

97

DIMENSIONS (mm)

SPECIFICATIONS

Duct

(mm)

Max. 

Fan Watts

(W)

Max. 

Fan Pressure

(Pa)

Free Air Fan Performance

Specific

Fan Power

(W/l/s)

Sound

dB(A)

(l/s)

(m

3

/hr)

125mm & 150mm

85

206

98

505

0.90

52

TECHNICAL

Supply

Max. Operating Temp

IP Rating

Motor Housing

Impeller & Outer Rotor

Weatherproof Cowl

Ducting

220-240V AC, 50Hz

40°C

IPX2

Die Cast Aluminium

PBT Plastic

150mm Stainless Steel

Aluminium Foil

Compliance: AS/NZS60335-2.80:2016

The MultiVent continuous extract ventilation is designed for the simultaneous 

ventilation of separate areas in the home and as a multipoint extraction 

system for a wide range of commercial applications. The units can be wall, 

ceiling or loft mounted. Where the ambient air has a high humidity content 

condensate drains are provided. 

SEC

Control

Max.

Leakage Rates

Annual Electricity

Consumption

(kWh/a)

Annual Heating Saved

(kWh/a)

Class

Value

Average

Warm

Cold

Factor

Typology

Internal %

External %

Average

Warm

Cold

B

-26.9

-11.4

-54.0

0.65

Local 

Demand 

Control

<5

<5

0.6

28.3

12.8

55.4

TYPICAL EXTRACTION LOCATIONS - BATHROOMS, TOILETS, LAUNDRIES, KITCHENS

The unit uses a highly efficient backward curved centrifugal motor impeller set and is designed for continuous 24 hour use. Four settable speeds 
can be configured to change these speeds based on an integrated sensor or separate switch inputs (not supplied). The unit will run at a normal 
flow rate until the humidity sensor or external switch input trigger a speed change. In the case of the switched live  and digital inputs, the units  
will perform a step change in speed to the appropriate level. In the case of the analog inputs and humidity sensor, the unit can be programmed  
to give a proportional response to the change in conditions.

B

B

A

A

C

D

F

E

Ø F

Summary of Contents for FAN7200

Page 1: ...2016 The MultiVent continuous extract ventilation is designed for the simultaneous ventilation of separate areas in the home and as a multipoint extraction system for a wide range of commercial applications The units can be wall ceiling or loft mounted Where the ambient air has a high humidity content condensate drains are provided SEC Control Max Leakage Rates Annual Electricity Consumption kWh a...

Page 2: ...the sides and rear Do not use near or in the immediate vicinity of a bath or swimming pool or any wet areas When installing fan through an external wall an external wall grille must be fitted at all times This appliance incorporates an earth connection for functional purposes only To protect against electric shock do not immerse cord or plug in water or any other liquids Do not insert or allow for...

Page 3: ...firmly all the way down the spigot clamping the aluminium foil ducting in place on the spigot To prevent the spigot being pushed out have another person pushing up from below Complete the other two rooms following the same instructions Cut a 126mm minimum hole in the required locations in the kitchen minimum 2m away from the stove top bathroom and toilet Disassemble the 125mm diffusers DCT0186 and...

Page 4: ...d to the LS terminal instead of connecting to a lighting circuit Terminal Description Connection Terminal Description Connection 1 L Live 220 240V AC L3 Brown 4 LS1 Live Switched 1 220 240V AC isolated L2 Black 2 N Neutral N Blue 5 LS2 Live Switched 2 220 240V AC isolated L1 Grey 3 Protective Earth E Green Yellow 6 NS Neutral Switched isolated Link to N NOTE LS1 LS2 and NS terminals are electrical...

Page 5: ... time if over run is enabled UNIT ADJUSTMENT 1 Commissioning and configuration on all products is supported by the 3 digit user interface and associated push buttons 2 When powered on the unit will display the firmware revision number after a few seconds the unit will display the first option in the menu structure see below 3 The display will enter standby mode after 30 seconds press the Mode butt...

Page 6: ...le of how to wire and control an MultiVent system hardwired to a Bathroom Kitchen and Toilet The MultiVent will utilize Humidity Rapid Rise in its response and the 2 larger rooms Bathroom and Kitchen will also provide a PURGE speed function if these 2 rooms are switched on together Before commencing please ensure that all power is OFF and ensure that it is electrically safe before starting Wire th...

Page 7: ...exity of assembly Only the full scroll assembly is replaceable 2 To remove the scroll assembly isolate the power then use a coin or similar to depress the cover retention clips and remove the cover 3 Disconnect and remove the power supply and signal leads 4 Remove the scroll assembly by unscrewing the two screws and unclipping the clips in the opposite two corners and lift the scroll assembly out ...

Reviews: