Kinetic MVHR Range 

 

Installer & Homeowner 
Guide 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stock Ref. N° 

438222   Kinetic B Right 
438222L Kinetic B Left 
443319   Kinetic BH Right 
443319L Kinetic BH Left 
408167   Kinetic FH Right 
408169   Kinetic FH Left 
443028   Kinetic Plus B Right 
443028L Kinetic Plus B Left 
408449   Kinetic High Flow Right 
408451   Kinetic High Flow Left 

 

 

DOWNLOAD INSTALLATION & USER GUIDE 
BY SCANNING THE QR CODE.  
OR GOTO:-

 https://www.vent-axia.com/residential-systems-manuals

 

 

INSTALLATION MUST BE CARRIED OUT BY SUITABLY

 

TRAINED AND QUALIFIED PERSONS. 

THE INSTRUCTIONS MUST BE READ BEFORE STARTING UP THE UNIT AND 
SHOULD BE KEPT WITHIN REACH OF THE INSTALLATION AND SERVICE 
TECHNICIAN

.

 

 

 

For replacement filters  

goto:-  

https://www.vent-axia.com/residential-systems

-manuals

 

 

Or scan the QR Code below to  
guide you to the Vent-Axia filter pages 

PLEASE LEAVE THESE INSTRUCTIONS WITH THE END USER OR WITH THE PRODUCT. 

 

 

 

Original Instructions  

Filter check record:- Select interval Required 
Installer to tick as appropriate. 

Note:- This is dependent on the environment in which the unit is installed. 

Please add the date of the next  
required filter change below:- 

Please fill in commissioned  
motor speeds in the table below:- 

Summary of Contents for Kinetic B Right 438222

Page 1: ...NSTALLATION MUST BE CARRIED OUT BY SUITABLY TRAINED AND QUALIFIED PERSONS THE INSTRUCTIONS MUST BE READ BEFORE STARTING UP THE UNIT AND SHOULD BE KEPT WITHIN REACH OF THE INSTALLATION AND SERVICE TECH...

Page 2: ...g use of the appliance by a person responsible for their safety Young children should be supervised to ensure that they do not play with the appliance The installer is responsible for the installation...

Page 3: ...erates continuously on Normal setting to ensure your home is ventilated at the appropriate level The system will automatically boost to a higher extract rate when one of the control devices is activat...

Page 4: ...nsion Diagrams RH Right handed version Kinetic B BH LH Left handed version Kinetic B BH RH Right handed version Kinetic F Plus High Flow LH Left handed version Kinetic F Plus High Flow INFORMATION FOR...

Page 5: ...ly or horizontally Do not use this unit as a support for any other equipment Wall Mounting 1 Refit the front and rear covers if they have been removed 2 Ensure the two steel wall bushes are fitted to...

Page 6: ...given in the installation operation and maintenance instructions that MUST be downloaded from https www vent axia com residential systems manuals 1 MAINS SUPPLY VOLTAGES 220 240 V AC ARE PRESENT IN TH...

Page 7: ...al 5 Internal 5 External 5 Internal 5 External Mixing Rate of Non Ducted BVUs not intended to be equipped with one duct connection on either supply or extract air side N A N A N A N A Position and des...

Page 8: ...al or workmanship In the event of any part being found to be defective the product will be repaired or at the Company s option replaced without charge provided that the product Has been installed and...

Reviews: