INTERMITTENT EXTRACT FAN  
 
Installation and Wiring Instructions 

 

Stock Ref. N° 

Solo Pro P 

409159 

Solo Pro T 

409160 

Solo Pro HTP  409161 
Solo Pro TM  409162

 

 

 

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. 
PLEASE SAVE THESE INSTRUCTIONS. 

 
 

Solo Pro

 

IPX4 

220-240V~50Hz 

 

Summary of Contents for Solo Pro HTP

Page 1: ...ation and Wiring Instructions Stock Ref N Solo Pro P 409159 Solo Pro T 409160 Solo Pro HTP 409161 Solo Pro TM 409162 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Solo Pro IPX4 220 240V 50Hz ...

Page 2: ... Phase complies with the rating label D The Fan should only be used in conjunction with the appropriate Vent Axia products E The fan should only be used in conjunction with fixed wiring F When the Fan is used to remove air from a room containing a fuel burning appliance ensure that the air replacement is adequate for both the fan and the fuel burning appliance G The Fan should not be used where it...

Page 3: ...re the fan as described in Section B Wiring Adjust any settings as required see Section C Setup 8 Replace the PCB and inner covers and impeller 9 After installation ensure impeller rotates freely Replace the front panel WALL MOUNTING FIG 4 1 For wall mounting cut a 117mm diameter hole through the wall and insert the wall sleeve Slope the sleeve slightly downwards away from the fan Where necessary ...

Page 4: ... TIMER SHOULD ONLY BE ADJUSTED BEFORE OR DURING INSTALLATION 1 Remove the fan grilles and PCB cover The product is factory set at 15 minutes approx The overrun period can be adjusted from 3 25 minutes by altering the pot on the control PCB 2 To REDUCE the operating time use a small screwdriver to turn the pot ANTI CLOCKWISE 3 To INCREASE the operating time use a small screwdriver to turn the pot C...

Page 5: ...RD is switched into the off position the fan will deactivate The HTP model will return to the Auto sensing mode D SERVICING AND MAINTENANCE WARNING THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING MAINTENANCE 1 At intervals appropriate to the installation the fan should be inspected and cleaned to ensure there is no build up of dirt or other deposits 2 Carefull...

Page 6: ...r 2 Remove the two screws as shown 3 For P and HTP models remove the pull cord clip L Switched Fused Spur 1 Phase Supply 220 240V 50Hz N L FUSE N N L 5 4 3 5A Fig 3 Solo Pro TM Visionex PIR Controller Please follow the fitting and wiring instructions for the Visionex PIR Controller for full installation instructions Solo Pro TM ...

Page 7: ... together to release the impeller 5 Remove two screws as shown Fig 5 Wiring and settings Supply cable via side or rear Supply cable connections Secure Supply cable with Cable Clamp Adjust Timer overrun or Humidistat set point model dependant as shown ...

Page 8: ...ogy Control Factor CTRL 1 00 0 95 0 65 0 65 Control Typology Manual Control Clock Control Local Demand Control Local Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage Rates for Ducted UVUs N A N A N A N A Mixing Rate of Non Ducted BVUs not intended to be equipped with one duct connection on either supply or extract ...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...lect or damage Has not been modified or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product carriage paid to your original supplier or nearest Vent Axia Centre by post or personal visit Please ensure that it is adequately packed and accompanied by a letter clearly marked Guarantee Claim stating the nature of the fault and pro...