Instruction Manual 

 

     Basic Rack PDU 

 

 VP7541 and VP9571A 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

VertivCo.com/geist 

 

Summary of Contents for VP7541

Page 1: ...Instruction Manual Basic Rack PDU VP7541 and VP9571A VertivCo com geist ...

Page 2: ...re 3 Humidity 3 Elevation 3 Electrical 3 Receptacle Ratings 3 EMC Verification 3 Installation 4 Instructions 4 Guidelines 4 Mounting 5 Optional Local Monitoring 12 Power Meter 12 Current Meter 12 Service Tech Support 13 Service and Maintenance 13 More Technical Support 13 ...

Page 3: ...000 m 6561 ft max Storage 0 m 0 ft min 15240 m 50000 ft max Electrical See nameplate for unit ratings Receptacle Ratings NEMA 5 15R or L5 15R 125 Volts 15 Amp NEMA 5 20R or L5 20R 125 Volts 20 Amp NEMA 6 20R or L6 20R 250 Volts 20 Amp IEC 320 C13 125 250 Volt 15 Amp per Receptacle Bank IEC 320 C19 125 250 Volt 20 Amp EMC Verification This Class A device complies with part 15 of the FCC Rules Opera...

Page 4: ...he effect that overloading of the circuits might have on over current protection and supply wiring The PDU relies on the building installation for protection from over current conditions A certified overcurrent protection device is required in the building installation The overcurrent protection device should be sized according to the PDU s nameplate ratings and local national electrical codes Rel...

Page 5: ...BASIC RACK PDU 5 Mounting Full Length Bracket Using the full length bracket mount PDU to rack as shown Mini L Brackets SLB 4 ...

Page 6: ...al Extension Brackets VCB 1 Using the vertical extension brackets attach PDU to rack as shown Toolless Mounting Hardware 11621 Secure toolless mounting buttons to PDU as shown Use toolless buttons with key holed slots built into cabinet or with optional Vertiv key holed brackets ...

Page 7: ...acket TLFL Using full length toolless bracket and toolless mounting buttons attach PDU to rack as shown Single Side Mount 2 Unit Brackets TSMX2 Using single side mount 2 unit brackets and toolless mounting buttons attach PDU to rack as shown ...

Page 8: ...BASIC RACK PDU 8 Offset Side Mount Brackets EZB 1 Using the offset side mount brackets attach PDU to rack as shown 7 Extension Brackets XB 7 Using the 7 extension brackets attach PDU to rack as shown ...

Page 9: ...BASIC RACK PDU 9 Flush Mount Brackets FM Using flush mount brackets attach PDU to rack as shown Adjustable Mount Brackets AM Using adjustable mount brackets attach PDU to rack as shown ...

Page 10: ...ASIC RACK PDU 10 Panel Mount Brackets PM Using panel mount brackets attach PDU to rack as shown 23 Conversion Mounting Brackets 23 RM Using conversion mounting brackets attach 19 PDU to 23 rack as shown ...

Page 11: ...able Mount Bracket CMB 1 Attach cable mount bracket to PDU as shown use tie wraps to secure cords to bracket 19 Horizontal Panel Mount Brackets 7938 Using the 19 horizontal panel mount brackets attach PDU to rack as shown ...

Page 12: ...ured in true RMS Amps Voltage PDU output voltage measured in true RMS Voltage Power PDU output power measured in Watts referred to as real or active power Power Factor Ration of real PDU output power to apparent PDU output power Power Meter Display Real power is the power in a circuit that is transformed from electric to non electric energy while apparent power is the total power supplied to the c...

Page 13: ...U or you may void the warranty No serviceable parts inside It is recommended that power be removed from the unit before installing or removing any equipment More Technical Support VertivCo com geist Phone Support 1 800 432 3219 Email support VertivCo com or contact your distributor Technical Support Form vertivco com Tech Support ...

Page 14: ...BASIC RACK PDU 14 Thank You For Purchasing Your Vertiv Product VertivCo com geist ...