Page 1: ...Instruction Manual Basic Rack PDU VP9559 VP7552 and VP7551 VertivCo com geist ...

Page 2: ...ions 8 2 4 1 Software 8 2 4 2 Hardware 9 2 4 3 Safety 10 2 4 4 Figures 11 2 4 5 Tables 11 3 Chapter 1 Product Specifications 12 3 1 Overview 12 3 2 Environmental 12 3 2 1 Temperature 12 3 2 2 Humidity 13 3 2 3 Elevation 13 3 3 Electrical 14 3 3 1 Receptacle Ratings 14 3 4 Regulatory Compliance 14 3 4 1 Underwriters Laboratories UL 14 3 4 2 CE 14 3 4 3 Federal Communications Commission FCC 15 3 4 4...

Page 3: ...6 Chapter 4 Final Checkout 25 6 1 Final Checkout 25 6 1 1 Technical Support 25 6 1 1 1 Service and Maintenance 25 6 1 1 2 More Technical Support 25 6 2 Product Specific Safety Notices 25 6 2 1 General Safety 25 6 2 2 Live Circuits Safety 26 6 2 3 Equipment Grounding 26 6 2 4 Electrostatic Discharge 27 6 2 5 Explosive Environment 27 6 2 6 Servicing and Adjustments 27 6 2 7 Repairs and Modifications...

Page 4: ...registered to Geist a division of Vertiv Inc Use and Disclosure Restrictions The software and documentation contained in this publication are copyrighted materials Recovery Act Buy American Vertiv products adhere to the Buy American provisions of the American Recovery and Re investment Act of 2009 Recovery Act All Vertiv goods manufactured in our Lincoln Ne braska plant have undergone substantial ...

Page 5: ...gsten or gold used in our products back to the smelter Vertiv will document our efforts to trace tin tantalum tungsten and gold miner als back to the smelter and will accurately report the results to our customers Vertiv will continue to monitor industry progress in identifying conflict free smel ters and will adjust corporate policy as the electronics supply chain becomes more fully documented Ve...

Page 6: ...arty Please contact Vertiv Europe on 01823 275100 for further details or to arrange collection UK Only Document Usage All reasonable efforts have been made to assure the accuracy of this document from any technical or typographical errors or omissions Vertiv a division of Vertiv Inc and its af filiates disclaim responsibility for any labor materials or costs incurred as a result of us age of this ...

Page 7: ...uipment 2 1 REVISION HISTORY Revision Date Notes Approved By 1 0 4 30 2009 Original Published Version BP 1 1 7 8 2009 Added Link Speed Information BP 1 2 6 29 2010 Updated Current Monitoring Meter Name BP 1 3 1 24 2011 Add Satellite Current Monitoring SC BP 1 4 3 12 2012 Add Packet Power CG 1 5 8 6 2012 Logo Update CG 1 6 8 20 2012 Added MJ Series CG 2 0 7 28 2014 Layout changes GY 3 0 9 2 2014 Co...

Page 8: ...upporting systems Setup This chapter provides instructions on power up procedures after product installa tion and configuration of the software and features Final Checkout Technical Support guidelines and safety information are provided in this chapter 2 3 AUDIENCE PROFILE This document is intended for use by authorized technicians experienced with same of similar product types and for personnel r...

Page 9: ...ct Classification o Power Distribution Unit Basic Monitored only Switched only Monitored Switched o Environmental Monitoring o Cooling o Data Center Infrastructure Management DCIM Figure 1 Overlay Symbology Guide Figure 1 The chart above depicts the symbols used on Vertiv overlays ...

Page 10: ...esentations are DANGER INDICATES AN IMMINENT HAZARDOUS SITUATION WHICH IF NOT AVOIDED WILL RESULT IN DEATH OR SERIOUS INJURY WARNING INDICATES A POTENTIAL HAZARDOUS SITUATION WHICH IF NOT AVOIDED COULD RESULT IN DEATH OR SERIOUS INJURY CAUTION INDICATES A POTENTIAL HAZARDOUS SITUATION WHICH IF NOT AVOIDED COULD RESULT IN PRODUCT DAMAGE AND MINOR TO MODERATE INJURY NOTE Provides useful information ...

Page 11: ...Chapter Image Example Figure 1 1 Name and or Title goes here 2 4 5 TABLES Tables presented in this document are identified and designated as follows Table Chapter Image Example Table 1 1 Name and or Title goes here Column 1 Column 2 Column 3 Column 4 Column 5 Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text ...

Page 12: ...r connec tion to a 16A Mains AC circuit The PDUs are designed to be powered by a single phase AC input circuit The VP9559 VP7551 and VP7551 PDUs can optionally be configured with a Vertiv Current Meter that provides local metering of the input current 3 2 ENVIRONMENTAL 3 2 1 TEMPERATURE Table 1 1 Temperature Limits Minimum Maximum Operating 10 C 50 F 45 C 113 F Storage 25 C 13 F 65 C 149 F ...

Page 13: ... Page 13 3 2 2 HUMIDITY Table 1 2 Humidity Limits Minimum Maximum Operating 5 95 non condensing Storage 5 95 non condensing 3 2 3 ELEVATION Table 1 3 Elevation Limits Minimum Maximum Operating 0 m 0 ft 2 000 m 6561 ft Storage 0 m 0 ft 15 240 m 50 000 ft ...

Page 14: ...act per the below agencies and policies 3 4 1 UNDERWRITERS LABORATORIES UL UL Standards are used to assess products test components materials systems and performance and evaluate environmentally sustainable products renewable energies food and water products recycling systems and other innovative technologies The UL standards specific to this equipment are listed in the UL Online Certification Lib...

Page 15: ...S government agency overseen by Congress the commission is the United States pri mary authority for communications laws regulation and technological innovation The FCC standards specific to this equipment are This Class A device complies with part 15 of the FCC Rules Operation is subject to the following two con ditions 1 This device may not cause harmful interference 2 This device must accept any...

Page 16: ...recovery and disposal of waste EEE Restricted substances and their respective maximum concentration values are listed below Restricted Substance Maximum Concentration Value w w Cadmium Cd 0 01 Mercury Hg 0 10 Lead Pb 0 10 Hexavalent chromium Cr6 0 10 Polybrominated biphenyls PBB 0 10 Polybrominated diphenyl ethers PBDE 0 10 Bis 2 Ethylhexyl phthalate DEHP 0 10 Butyl Benzyl phthalate BBP 0 10 Dibut...

Page 17: ...20 Amp Branch Circuit For Global Units a 16 Amp rated PDU is intended for use on a 16 Amp Branch Circuit Guidelines If the PDU is installed in a cabinet the ambient temperature of the rack should be no greater than 45 C Install the PDU such that the amount of airflow required for safe operation of equipment is not compromised Mount the PDU so that a hazardous condition is not achieved due to uneve...

Page 18: ...is intended for Restricted Access Locations only and only qualified service personnel should install and access the PDU For pluggable equipment install the PDU so that the input plug or appliance coupler may be dis connected for service Sequential power up of devices powered by the PDU is recommended to avoid high inrush current Caution Disconnect all power cords before servicing The PDU is intend...

Page 19: ...e 19 Mini L Brackets SLB 4 Using the mini L brackets attach PDU to rack as shown Figure 2 3 Vertical Extension Brackets Vertical Extension Brackets VCB 1 Using the vertical extension brackets attach PDU to rack as shown Figure 2 4 Toolless Mounting Hardware ...

Page 20: ...on Manual Page 20 Toolless Mounting Hardware 11621 Secure toolless mounting buttons to PDU as shown Use toolless buttons with key holed slots built into cabinet or with optional Vertiv key holed brackets Figure 2 5 Toolless Full Length Brackets ...

Page 21: ...cket TLFL Using full length toolless bracket and toolless mounting buttons attach PDU to rack as shown Figure 2 6 Single Side Mount 2 Units Brackets Single Side Mount 2 Unit Brackets TSMX2 Using single side mount 2 unit brackets and toolless mounting buttons attach PDU to rack as shown ...

Page 22: ...e 22 Figure 2 7 Offset Side Mount Brackets Offset Side Mount Brackets EZB 1 Using the offset side mount brackets attach PDU to rack as shown Figure 2 8 7 Extension Brackets 7 Extension Brackets XB 7 Using the 7 extension brackets attach PDU to rack as shown ...

Page 23: ... VP9559 VP7552 and VP7551Instruction Manual Page 23 Figure 2 9 19 Horizontal Panel Mount Brackets 19 Horizontal Panel Mount Brackets 7938 Using the 19 horizontal panel mount brackets attach PDU to rack as shown ...

Page 24: ...M 1 current meter is a low power high accuracy meter capable of measuring true RMS Current The value of current is continuously shown on an easy to read 4 digit LED Display The Cur rent Meter will automatically begin to display value of output current when the PDU is connected to AC Mains power Figure 3 2 Current Meter Current Meter Display ...

Page 25: ...el only The IMD is designed to be replaced while the PDU is still connected to AC Mains power Please re fer to the IMD section of this document for removal and installation instructions 6 1 1 2 MORE TECHNICAL SUPPORT VertivCo com geist Phone Support 1 800 432 3219 Email support VertivCo com or contact your distributor Technical Support Form VertivCo com Tech Support 6 2 PRODUCT SPECIFIC SAFETY NOT...

Page 26: ...Operating personnel must Not remove equipment covers Only Vertiv Authorized Service Personnel or other qualified maintenance personnel may remove equipment covers for internal sub assembly or compo nent replacement or any internal adjustment Not replace any equipment component with power applied to the line cord Under certain conditions dangerous voltages may exist even with the input power cable ...

Page 27: ...tions have been established Any static producing packing materials such as plastic Styrofoam and some cardboards should be removed and discarded in a timely manner 6 2 5 EXPLOSIVE ENVIRONMENT Do not operate this equipment in the presence of flammable gases or fumes Operation of any electrical equipment in such an environment constitutes a definite safety hazard 6 2 6 SERVICING AND ADJUSTMENTS Do n...