background image

 

DIN-Rail Power Switch Meter (PSM-DIN2-ZW Series)   

          

 

 

The Power Switch is capable of receiving wireless signals from the coordinator in the Z-Wave network to toggle On/Off of 
appliances that are attached to it.  The Power Switch also features keeping  tracks of energy consumption with built-in 
power meter and transmit the data to the Z-Wave network regularly. 
The Power Switch is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. 
Z-Wave is a wireless communication protocol that uses a low-power RF radio. By taking advantage of the Z-Wave mesh 
network, commands can be transmitted to their destination via intermediary “listening” Z-Wave products. 

 

The PSM-DIN2-ZW series includes the following models: 

PSM-DIN2-ZW 

PSM-DIN2-ZW-OTA 

 

 

Identifying the Parts   

1.  Input Connector   

2.  Output Connector   

3.  External Antenna Port   

4.  LED Indicator   

5.  Function Button   

-Press the Function Button 3 times within 1.5 seconds 

to send a learn code. 

-Press and hold for 10 seconds to factory reset. 

 

 

LED Indicator   

 

On: power on 

 

Off: power off 

 

Red light flashes twice: 1. The Power Switch has just been powered on, 

or

 

2. The Power Switch has just been factory reset. 

 

Caution 

 

All works on the device, including installation and maintenance, must be performed by a qualified and   

licensed electrician. 

 

Before installation or any maintenance work, make sure the power supply has been disconnected. 

 

Do not connect the device to loads exceeding supported load current. 

 

Wiring and Installation 

Before installation, make sure the power supply has been disconnected. 

 

Connect L terminal of input connector to the L terminal of Power Supply, please use 
fuse for the wire. Connect N terminal of input connector to the N terminal of Power 
Supply.   

 

Connect  N  terminal of output connector  to the N  terminal of external device, and 
connect L terminal of output connector to the L terminal of external device. 

 

Connect the external antenna to the external antenna port. 

 

Mount the device inside the electrical enclosure using a DIN rail.    

 

Inclusion (Adding or Learning Device) 

This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other 
manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters 
regardless of vendor to increase reliability of the network. 
 

  Power on the device by turning on external power supply. 

 

Put the Z-Wave  Gateway or Control  Panel into

  Inclusion 

or

  Learning

  mode (please refer to the Z-Wave 

Gateway or Control Panel manual). 

 

Within 1.5 seconds, press the Function Button 3 times. 

 

Refer to the operation manual of the Z-Wave Gateway or Control panel to complete the adding process. 