background image

Viasis 3003

viasis the mobile and independent

speed indicator system

 1

User Manual

Revision 4.1, 8 March 2017

1

 This system is based on a development supported with funds of the German ministry of research and technol-

ogy with the project no. 35-250368, with the assistance of  the German ‘Fraunhofer Gesellschaft ISE‘

via

traffic

controlling

GmbH

Campusallee 1
D-51379 Leverkusen
Germany
Tel. +49 - (0)2171 - 50 49 30
Fax. +49 - (0)2171- 50 49 50
Email:

info@viatraffic.de

Web:

http://www.viatraffic.de

Summary of Contents for Viasis 3003

Page 1: ...elopment supported with funds of the German ministry of research and technol ogy with the project no 35 250368 with the assistance of the German Fraunhofer Gesellschaft ISE via traffic controlling Gmb...

Page 2: ...erface connection optional 13 6 2 3 1 Windows XP and Vista 32 bit USB device driver installation 14 6 2 3 2 Windows Vista 64 7 8 8 1 USB driver installation 16 6 2 3 3 USB driver for Windows 10 18 6 2...

Page 3: ...onfigure SMS 50 6 4 3 GPS Module optional 51 6 4 3 1 GPS position list 52 6 4 3 2 Formatted GPS data output 53 6 4 3 3 GPS raw data NMEA 183 protocol 54 6 4 3 4 GPS position fix time 54 6 5 Menu infor...

Page 4: ...s 3003 CE compliance and notification 75 9 3 CE conformity Bluetooth module Laird 730 SA 76 9 4 CE expertise M10 Quectel GSM GPRS radio module 77 9 5 Viasis 3003 FCC and IC compliance 78 10 ANNEX 79 1...

Page 5: ...ned citizens The police are and was never able to observe the mentioned low speed zones and living areas in a repressive manner effectively and the expenses for repressive supervision there are not co...

Page 6: ...misconduct with serious conse quences Danger of hazardous voltages mortal danger Helpful hints tips and recommendations Troubleshooting advice Standard text Normal text instructions Bold text Highligh...

Page 7: ...ds due to sun or vehicle light reflection Alternating with the numeric speed display several warning and speed limit sign symbols with a circle diameter of 300 mm can be shown Optionally the viasis 30...

Page 8: ...trees poles high parking vehicles and so on The system shall not be used in the range of road turns and bends Otherwise too low meas ured speeds can be the result For the fixation of the viasis at pol...

Page 9: ...to a measurement angle of 5 see illustration 3 Illustration 3 viasis display directed away from the road with a measurement angle 5 A measurement angle of more than 5 lead to the display of too small...

Page 10: ...nel During the mounting the fixed text of the viasis MINI is folded in the visible upright position by means of a movable flap board see illustration 5 If the flap board is open and upright both hinge...

Page 11: ...7 The 5 ampere system fuse should already be placed into the fuse holder on the control panel Press the On Off toggle switch labeled 1 0 in position 1 so that the viasis is turned on Illustration 7 sh...

Page 12: ...p For smartphones and tablets with Android operating system version 4 0 and higher the ViaApp can be installed for the communication with the viasis by the Bluetooth interface The file viatraffic_app_...

Page 13: ...age click on the line viagraph and the installation of the software package is started The software package viagraph al lows the evaluation of measurement data of Via devices Further a com munication...

Page 14: ...on the control panel in the battery box see also illustration 7 Connect the battery to the viasis and power it by the On Off switch if not done already Start the viagraph program with a mouse double c...

Page 15: ...keyboard to the viasis menu system directly Menus messages and responses from the viasis are displayed then in the terminal area The more comfortable way to change viasis parameters is to click the S...

Page 16: ...interface adapter has been correctly installed as a serial COM port you may check it in the windows Device manager Unfortunately the way to respectively the place ment of the device manager varies wit...

Page 17: ...aware of The viasis cannot be supplied by the USB interface therefore the viasis must by powered e g by a charged 12Volt battery for establishing a data connection The internal viasis microcontroller...

Page 18: ...me consuming and not needed so click No not this time and Next see picture right aside Enter the delivered Via CD ROM in the DVD CD ROM drive of your computer Choose Install from a list and click Next...

Page 19: ...installation with administrator rights After a succesful USB driver installation you should also find it in the Windows Device manager Start Control Panel Performance and Maintenance System Hardware...

Page 20: ...en the Devices and Printers window see illustration 21 either by the Windows Start menu or the Control Panel Illustration 21 Windows Devices and Printers Click with the right mouse button on the symbo...

Page 21: ...l System and Security System Device Manager In the device class Other devices you will see the de vice USB_CDC0_0 Make a right mouse click to USB_CDC0_0 and select Update driver Software in the displa...

Page 22: ...ph and other terminal software can communicate now with the viasis 6 2 3 3 USB driver for Windows 10 Under Windows 10 in case a USB CDC communication device class system is con nected the first time t...

Page 23: ...measurement data in a file VTF in the VIASIS folder Stored measurement data in the viasis are deleted afterwards If a firmware file1 BIN is found in the VIASIS folder it is loaded and a firmware up d...

Page 24: ...tion of the viasis system parameter settings offline is that the viasis type and version is already known to the viagraph program Either you connect the viasis directly to your computer and click on t...

Page 25: ...ameters directly to the USB stick Before you click the USB Stick button select the correct USB Stick Drive letter If you plug in the USB stick with the changed parameters at your viasis the parameter...

Page 26: ...If standard generic Windows Bluetooth interface drivers are used for the Bluetooth modem operation the initial configuration of the Bluetooth connection is shown for Windows 7 below Open Devices and...

Page 27: ...e if reflectors buildings fences or vehicles are nearby Internal Bluetooth modems of laptops notebooks and mini computers are in common designed for the connection of peripheral Bluetooth devices like...

Page 28: ...Finally a virtual COM port must have been created in the Windows Device manager typical either in the device class COM LPT or Mo dems Properties Extended see also chapters 6 2 2 and 6 2 3 Before you...

Page 29: ...is established the viagraph connection window with the viasis main menu in the terminal is shown see illustration 11 Depending on the viasis type rec ognized by viagraph several buttons appear on the...

Page 30: ...tomatically connected by viagraph In this cases or a combination of them please have a look in the Windows Device manager see chapters 6 2 2 and 6 2 3 particularly in the device classes COM LPT Blueto...

Page 31: ...iasis by clicking the Transfer button otherwise the changes are discarded Hint To avoid a malfunction of viagraph take care that the viagraph terminal window shows the viasis main menu before you clic...

Page 32: ...sensitivity are the same for all parameter sets and times 6 3 1 Parameter set A parameter set is the collection of all display parameters of the submenus Speed display op tions and Extensions thresho...

Page 33: ...he valid times and days which are defined for the 2nd parameter Set If you want to know which parameter set is active in the viasis you need to look into the main menus submenu Information and Time In...

Page 34: ...defined there fore they are deactivated In time periods not covered by the time schedules no measurements and self evident no display opera tion will happen The viasis is in a low power energy saving...

Page 35: ...o the list of operation days in the Time schedule menu if it was not listed before respectively removed from the list if it was listed 6 3 2 3 Time schedule Daily start and daily stop time The daily s...

Page 36: ...rameter set 2 measures without displaying the speed on the numeric LED display 6 3 3 Bidirectional detection The viasis radar detects also the data of leaving vehicles whose data by default are not st...

Page 37: ...hicle speeds shall be measured exactly e g for drive in weigh bridges the display of a decimal digit until 19 9 km h or mph can be activated by entering 1 in the Speed display options menu and further...

Page 38: ...isplay is alternated for 0 25 seconds on and 0 25 seconds off time In a display update cycle with 1 5 seconds length the numeric speed blinks up 3 times in short sequence This function can be used to...

Page 39: ...Balanced 3 Visibility Your choice 1 3 If the option Operating time is chosen the display appears darker and reaches maximal 50 of the possible brightness adjusted ex factory If you choose Visibility t...

Page 40: ...ed speed thresholds for the activation and deactivation are placed in the Settings Thresholds Extensions menu The display of speed limit or warning symbols alternates with the numeric speed display Th...

Page 41: ...nus of the Thresholds Extensions menu see chap ter 6 3 6 can be changed however not the number of symbols in the menus For example if you need the circle symbols 8 25 and 50 instead of the symbol grou...

Page 42: ...th font number 500 to 503 defined see following table 1 Font 401 499 500 501 502 503 Symbol Example 425 Table 1 Font numbers of the circle symbols In the later menu presentation the text Led symbols i...

Page 43: ...alled relays the menu for their related speed thresholds in the menu Extensions Thresholds Relays will look similar to the following menu Relays 1 Relay 1 on 31 km h 2 Relay 1 off 51 km h 3 Relay 2 on...

Page 44: ...th LED fixed text the activation range of two or more texts shall not overlap The simultaneous display of two fixed texts will cause an unreadable result The viasis PLUS shows in case of the simultane...

Page 45: ...tion and Time see chapter 6 5 The content of the menu Radio modems varies depending on installed radio interfaces Radio modems 1 Bluetooth modem 2 GSM GPRS modem 3 GPS module 4 Back Your choice 1 4 If...

Page 46: ...gal access e g by Bluetooth or GSM connection the hint Access impossible will be displayed on a connected terminal 6 4 1 1 Bluetooth device name The so called local device name can be changed and is s...

Page 47: ...3 2 3 The menu items Operation weekdays and Daily start stop time define only the days and the time span during which the viasis GSM GPRS modem remains powered and can be called by a dial up GSM conne...

Page 48: ...ry you need to define the daily delivery time 4 Email delivery Daily 5 Time 03 00 The time value is set in the format hh mm with time values between 00 00 and 23 59 For the mail delivery interval Week...

Page 49: ...number to enter the 4 digit PIN code delivered from the service provider together with the SIM card for example Pin number 1234 Return In case the SIM2 card is already inserted in the push pull SIM ca...

Page 50: ...ion Change y n with y for yes the APN access point net work the related USER username and PASS pass code will be requested sequentially by the viasis Valid entries are up to 31 alphanumeric characters...

Page 51: ...not set not set Orange Switzerland internet not set not set Sunrise Switzerland internet internet internet Request the GPRS access data if not known from your SIM card and ser vice provider You can de...

Page 52: ...ommon the E mail sender owns a user mail account at the providers mail server Nowadays rarely exist also open mail relay server forwarding each mail they get from whoever with no authorized login need...

Page 53: ...ct our technical support please provide the protocol of the failed SMTP server configuration which is essential to analyze the problem 6 4 2 5 E mail configuration With the GSM Email menu item Configu...

Page 54: ...n to the question Change y n but y to Send email y n If you are connected by RS232 the E mail is send immediately else if you are connected by GSM USB or Bluetooth interface the mail is send as soon...

Page 55: ...d contact our technical support please provide the connection protocol as text or snapshot attached to a send E mail The connection protocol is essential for a failure analy sis 6 4 3 GPS Module optio...

Page 56: ...e the position determination is not done permanently Instead the position is determined after the viasis power on and further continu ously repeated after the time set in the Position fix time The fix...

Page 57: ...measurement data and GPS coordinates easy the viasis system date and time and not the satellite time UTC1 is stored in the GPS position list 6 4 3 2 Formatted GPS data output After entering 2 for For...

Page 58: ...62 E 0 00 0 00 011015 A 64 GPVTG 0 00 T M 0 00 N 0 01 K A 3C GPGGA 073114 000 5103 5574 N 00700 9062 E 1 7 1 05 75 5 M 47 6 M 63 GPGSA A 3 05 25 26 29 31 21 23 1 36 1 05 0 86 01 GPGSV 3 1 12 29 71 062...

Page 59: ...splay operation at the time the menu is called If at this time no parameter set is valid the number 0 null is given The item comments shows typically information like measurement location or other giv...

Page 60: ...th postal code city street and number and the measured lane direction The data of the comment text field are transferred in the header of the viasis measurement data file VTF file and will be shown in...

Page 61: ...ountry Daylight saving time 1 off 2 UTC 0 3 UTC 1 4 UTC 2 Your choice 1 4 For the United Kingdom Ireland Portugal please choose UTC 0 for Spain France Ger many Poland UTC 1 and for Greece and Finland...

Page 62: ...ment data blocks This is equivalent at a radar range of 120 meter and an average vehicle speed of 50 km h about 36833 73806 or 146345 vehicles The measurement data store should be deleted after a data...

Page 63: ...to the main menu otherwise it re ports the number of stored speed values Number of values 21233 It follows the question Send data y n If you enter y the measurement data are send to the terminal alwa...

Page 64: ...urther the thresholds for blinking LED display LED color change and LED mixed color as well as for the integrated warning symbols defined in parameter set 1 are recognized for the equivalent display O...

Page 65: ...eshold parameters defined in the parameter set resp the threshold parameters of the Settings menu and the submenus Thresholds Exten sions and Speed display options for the numeric LED display the inte...

Page 66: ...o the viasis menu Otherwise the Viamatrix program will wait for further menu insertions and will not show any matrix message until you returned to the viasis menu The Viamatrix program has an input me...

Page 67: ...ers dig its and most punctuation marks except quotation marks which are used to label bitmaps and placeholders in the text Below the lines in the group field Line 1 scroll and Line 2 scroll determine...

Page 68: ...the page line the bitmap is placed by its bitmap number delimited by apostrophes e g 17 therefore the use of apostrophes in the text is not allowed In order to edit or create new bitmaps double click...

Page 69: ...r time and date can be used for example together with a permanent shown text page and a 230V net supplied viasis see also chapter 6 11 Placeholders are further used in special software which displays...

Page 70: ...olders for date and time the permanent 5th text page looks like in the matrix editor as follows Illustration 56 Matrix editor with date and time placeholder in permanent display page 6 11 Select switc...

Page 71: ...and so on Practically following factors have a reducing effect to the distance range High up to the edge of the driveway leading buildings trees poles parked cars and containers which hamper the free...

Page 72: ...ed digits 7 3 Accuracy The accuracy of the speed value is 2 and 1 digit for the whole measurement range Herewith the accuracy is better than specified for repressive velocity measurement systems in th...

Page 73: ...olt lead gel battery pack with a capacity of 17 Ah is installed in a small plastic box on the backside of the housing The viasis has a discharge protection for the accumulator to prevent irreversible...

Page 74: ...The industrial housing protection class is IP64 compare EN 60529 IP64 means that the sys tem is protected against intrusion of dust and the housing protected against water splashing from any direction...

Page 75: ...vel can be checked under load condition at power on 188 is displayed and the battery voltage value follows and when you connect a laptop or PC and use the test function main battery see also chapter 6...

Page 76: ...vehicle plug in type fuse Attention Replace the fuse by the same type Using fuses with higher cur rent values means in worst case a burned down system if an electric internal short circuit occurs 8 5...

Page 77: ...ations like high voltage lines radar or radio antennas in the near surrounding Is the minimal or maximal displayed speed set correctly see chapter 6 3 4 2 Is the Led display deactivated in the actual...

Page 78: ...ion by the insurance took place 8 8 Sending back transport preparation disposal Before you send the system for repair contact our support Sometimes systems do not operate due to parameter settings or...

Page 79: ...6 A11 2009 A1 2010 essential requirements standards specifications EN 55022 2011 12 EN 62311 VDE 0848 211 2008 09 EN 61000 4 2 3 8 2009 12 2011 04 2010 11 EN 50293 2002 02 EN 300440 1 V1 6 1 2 V1 4 1...

Page 80: ...traffic controlling gmbh 9 3 CE conformity Bluetooth module Laird 730 SA Test reports declarations for ROHS and REACH compliance for the BLUETOOTH module you will find on the manufacturer website htt...

Page 81: ...controlling gmbh 9 4 CE expertise M10 Quectel GSM GPRS radio module For the complete document with all attachments please see the delivered CDROM in folder Compliance Quectel_M10 For the list of appl...

Page 82: ...ice may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications made to this equipment...

Page 83: ...er 2 A Automatic charger 12 Volt 2 A for 17 Ah Accumulator viasis aluminum tripod Stable tripod collapsible with telescope pole weight 10 kg tri pod ground diameter up to 2 4m material eloxated alumin...

Page 84: ...5 s Hold time 3 s Integrated Led warning symbols Led circle diameter 300 mm Digit symbol height 190 mm Readability 120 m Fixed text Letter height 100 mm Readability 80 m Data memory Flash FIFO ring s...

Page 85: ...8 Watt Operating time 17 Ah battery 1 2 weeks LED matrix uni or bicolor 2 lines with 1 2 x 8 x 48 LED Line distance 50 mm Line dimensions W x H in mm 100 x 500 10 2 2 Supplementary data viasis PLUS SM...

Page 86: ...to 85 C Compliance CE FCC IC 10 3 Technical data optional components 10 3 1 Technical data Control panel USB USB host computer connector USB B socket type USB client USB stick connector USB A socket...

Page 87: ...trength 1 minute 1 kV 5kV between contacts contact to coil Isolation transient over voltages 10000 VAC for 1 2 x 50 s Max on off switch time 10ms 5ms Contact material Gold plated silver alloy Minimal...

Page 88: ...ore they are appropriate for supplementary customer specific external LED dis plays 10 3 6 Technical Data GSM GPRS radio module and SIM card slot Type of radio module Quectel M10 Transmit frequencies...

Page 89: ...chnical Data GPS module GPS module Quectel L70 L1 band receiver 1575 42 MHz Power consumption during position fix 20 mA 12V with active GPS antenna Position fix time TTFF 35 s optimal satellite recept...

Reviews: