background image

ODE-A4 Quick start guide 

 

Model: HAA-XX-XX-XX-XXXXX 

 

 

 

 

P

ULSE 

P

OWER AND 

M

EASUREMENT 

L

TD

.,

 

65

 

S

HRIVENHAM 

H

UNDRED 

B

USINESS 

P

ARK

,

 

S

WINDON

,

 

SN6

 

8TY,

 

UK. 

T

EL

:

 

+44

 

1793

 

784389

 

F

AX

:

 

+44

 

1793

 

784391 

E

MAIL

:

 

SALES

@

VIALITE

.

COM

       

W

EBSITE 

:

 

WWW

.

VIALITE

.

COM

 

 

 

Issue 2 

Page 1 of 2 

CR4635 

 
Precautions 

 

Electrical Safety 

ViaLite

  Power  Supply  Units  are Safety  Class  1  products  (having  metal case  directly  connected  to earth  via the  power  supply  cable). 

The  unit  is  also  fitted  with  an  earthing/grounding  stud  connected  to  the  power  supply  earth. When  operating  the  equipment  note  the 
following precautions: 

 

Hazardous voltages exist within the equipment. Modules have no user serviceable parts, do not remove covers. 

 

The  equipment  does  not  have  an  external  mains  isolating  switch.  Equipment  must  be  installed  within  easy  reach  of  a  dual  pole 
mains isolation switch. 

 

User replaceable fuses and module replacement should only be carried out by a qualified technician. 

 
ESD Precautions 

Precautions  for  handling  electro-static  sensitive  devices  should  be  observed  when  handling  all 

ViaLite

  modules.  Technicians  should 

ensure that they use effective personal grounding (i.e. ESD wrist strap etc.) when servicing the equipment. Any equipment or tools used 
should  be  grounded  to  prevent  static  charge  buildup.  Good  practice  should  be  observed  at  all  times  for  reference  see  relevant 
standards. 
EN 61340-5-

1, “Protection of Electronic Devices from Electrostatic Phenomena – General Requirements” 

 

Optical Safety 

The 

ViaLite

 RF Transmitter modules contain laser diode sources operating at nominal wavelengths of 1270nm to 1610nm.  

These devices are rated as EN60825-1 CLASS 1 radiation emitting devices. A class 1 laser is safe under all conditions of normal use. 
When operating the equipment note the following precautions: 

 

Never look into the end of an optical fibre directly or by reflection either with the naked eye or through an optical instrument. 

 

Never leave equipment with radiating bare fibres 

– always cap the connectors. 

 

Do not remove equipment external covers when operating. 

 

Modules fitted 

Below is a list of module fitted in your ODE-A enclosure and their special configurations 

 

PSU 

– LH 

LPS-A4   

 

ViaLiteHD Mains Power Supply for (ODE-A4) Outdoor Enclosure, 90-264VAC i/p  

 

PSU 

– RH 

LPS-A4   

 

ViaLiteHD Mains Power Supply for (ODE-A4) Outdoor Enclosure, 90-264VAC i/p 

 

Module 1 

HRT-G5-8M-10-S1310 

ViaLiteHD Transmitter, GPS & Galileo, 1.0-1.8GHz, 50

Ω, MCX RF, SC/APC Optical 

 

Module 2 

HRT-L5-8M-33-S1310 

ViaLiteHD Transmitter, L Band, 700-2450MHz, 50

Ω, MCX RF, SC/APC Optical 

 

Module 3 

HRT-L5-8M-33-S1310 

ViaLiteHD Transmitter, L Band, 700-2450MHz, 50

Ω, MCX RF, SC/APC Optical 

 

Module 4 

Not fitted 

 

 

 
 
 
 

Note 

Replaceable fuse, fitted to switch bar - Fuse, 2A, 250V, anti-surge, 20 x 5mm, 
PPM part number 57107 
 
 
 

 

Internal fibre connections: 
Module 1 = A 
Module 2 = B 
Module 3 = a 
Module 4 = b 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
ODE-A4 Glandplate connector information 

1 = 50 Ohm N-Type (RF1-4) 
2 = Neutrik Quad Fibre connector 
3 = Neutrik True 1 power input connector 

 

 

 

2

 

 

 

3

 

Reviews: