ODE-A4 Quick start guide
Model: HAA-XX-XX-XX-XXXXX
P
ULSE
P
OWER AND
M
EASUREMENT
L
TD
.,
65
S
HRIVENHAM
H
UNDRED
B
USINESS
P
ARK
,
S
WINDON
,
SN6
8TY,
UK.
T
EL
:
+44
1793
784389
F
AX
:
+44
1793
784391
E
W
EBSITE
Issue 2
Page 1 of 2
CR4635
Precautions
Electrical Safety
ViaLite
Power Supply Units are Safety Class 1 products (having metal case directly connected to earth via the power supply cable).
The unit is also fitted with an earthing/grounding stud connected to the power supply earth. When operating the equipment note the
following precautions:
Hazardous voltages exist within the equipment. Modules have no user serviceable parts, do not remove covers.
The equipment does not have an external mains isolating switch. Equipment must be installed within easy reach of a dual pole
mains isolation switch.
User replaceable fuses and module replacement should only be carried out by a qualified technician.
ESD Precautions
Precautions for handling electro-static sensitive devices should be observed when handling all
ViaLite
modules. Technicians should
ensure that they use effective personal grounding (i.e. ESD wrist strap etc.) when servicing the equipment. Any equipment or tools used
should be grounded to prevent static charge buildup. Good practice should be observed at all times for reference see relevant
standards.
EN 61340-5-
1, “Protection of Electronic Devices from Electrostatic Phenomena – General Requirements”
Optical Safety
The
ViaLite
RF Transmitter modules contain laser diode sources operating at nominal wavelengths of 1270nm to 1610nm.
These devices are rated as EN60825-1 CLASS 1 radiation emitting devices. A class 1 laser is safe under all conditions of normal use.
When operating the equipment note the following precautions:
Never look into the end of an optical fibre directly or by reflection either with the naked eye or through an optical instrument.
Never leave equipment with radiating bare fibres
– always cap the connectors.
Do not remove equipment external covers when operating.
Modules fitted
Below is a list of module fitted in your ODE-A enclosure and their special configurations
PSU
– LH
LPS-A4
ViaLiteHD Mains Power Supply for (ODE-A4) Outdoor Enclosure, 90-264VAC i/p
PSU
– RH
LPS-A4
ViaLiteHD Mains Power Supply for (ODE-A4) Outdoor Enclosure, 90-264VAC i/p
Module 1
HRT-G5-8M-10-S1310
ViaLiteHD Transmitter, GPS & Galileo, 1.0-1.8GHz, 50
Ω, MCX RF, SC/APC Optical
Module 2
HRT-L5-8M-33-S1310
ViaLiteHD Transmitter, L Band, 700-2450MHz, 50
Ω, MCX RF, SC/APC Optical
Module 3
HRT-L5-8M-33-S1310
ViaLiteHD Transmitter, L Band, 700-2450MHz, 50
Ω, MCX RF, SC/APC Optical
Module 4
Not fitted
Note
Replaceable fuse, fitted to switch bar - Fuse, 2A, 250V, anti-surge, 20 x 5mm,
PPM part number 57107
Internal fibre connections:
Module 1 = A
Module 2 = B
Module 3 = a
Module 4 = b
ODE-A4 Glandplate connector information
1 = 50 Ohm N-Type (RF1-4)
2 = Neutrik Quad Fibre connector
3 = Neutrik True 1 power input connector
1
2
3