background image

 

 

 
 

 

Vicon part number 8009-8134-60-01  

 

 

 

Section 3 Rev 108  

 

 

                                                      

XX134-60-01

  

 
 
 

 

Quick Guide for  

SurveyorVFT Camera Domes  

 

 
 
 
 
 
 

 

Warning: To reduce a risk of fire or electric shock, do not expose 
the indoor unit to rain or moisture.

 

 

Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your 
requirements or that the operation will be entirely error free or perform precisely as described in the 
documentation. This system has not been designed to be used in life-critical situations and must not be 
used for this purpose. 

 

  

  

 

 
 

Copyright © 2007 Vicon Industries Inc. All rights reserved. 
Product specifications subject to change without notice. 
Vicon and its logo are registered trademarks of Vicon Industries Inc. 
 
 
 
 

VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788 

TEL: 631-952-CCTV (2288)  FAX: 631-951-CCTV (2288) TOLL FREE: 800-645-9116 

24-Hour Technical Support: 800-34-VICON (800-348-4266) 

UK: 44/(0) 1489-566300      WEB: www.vicon-cctv.com

 

Summary of Contents for SurveyorVFTXX134-60-01

Page 1: ... or perform precisely as described in the documentation This system has not been designed to be used in life critical situations and must not be used for this purpose Copyright 2007 Vicon Industries Inc All rights reserved Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YO...

Page 2: ......

Page 3: ...Use only grounded outdoor cables to protect against voltage surges and static charges Section 810 of the National Electrical Code ANSI NFPA 70 1984 provides information on proper grounding of the lead in wire to an antenna discharge unit size of grounding conductors and the requirements of grounding electrodes 14 Lightning Disconnect the product from its power source and cable system when possible...

Page 4: ......

Page 5: ...ith coaxial UTP fiber or ViconNet video transmission 3 Standard PTZ SurveyorVFT Outdoor Pendant SVFT W series includes 22EX color ExView 23X and 35X day night 22X color models available with coaxial UTP fiber or ViconNet video transmission 4 SVFT M Impact Resistant SVFT M series includes 22X color 22EX color ExView 23X and 35X day night pendant models available with coaxial UTP fiber or ViconNet v...

Page 6: ...2 Introduction XX134 60 01 Rev 108 SurveyorVFT Camera Dome Quick Guide Quick Installation Standard PTZ In Ceiling Model Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N ...

Page 7: ...XX134 60 01 Rev 108 SurveyorVFT Camera Dome Quick Guide Introduction 3 Quick Installation Standard PTZ Indoor Pendant Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N ...

Page 8: ...4 Introduction XX134 60 01 Rev 108 SurveyorVFT Camera Dome Quick Guide Quick Installation Standard PTZ Outdoor Pendant Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N ...

Page 9: ...XX134 60 01 Rev 108 SurveyorVFT Camera Dome Quick Guide Introduction 5 Quick Installation SVFT M Impact Resistant Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N ...

Page 10: ...6 Introduction XX134 60 01 Rev 108 SurveyorVFT Camera Dome Quick Guide Quick Installation SVFT PRS Pressurized Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N ...

Page 11: ...XX134 60 01 Rev 108 SurveyorVFT Camera Dome Quick Guide Introduction 7 Quick Installation Fixed In Ceiling No Access to Ceiling Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N ...

Page 12: ...8 Introduction XX134 60 01 Rev 108 SurveyorVFT Camera Dome Quick Guide Quick Installation Fixed In Ceiling Access to Ceiling Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N ...

Page 13: ...XX134 60 01 Rev 108 SurveyorVFT Camera Dome Quick Guide Introduction 9 Quick Installation Fixed Indoor Pendant Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N ...

Page 14: ...10 Introduction XX134 60 01 Rev 108 SurveyorVFT Camera Dome Quick Guide Quick Installation Fixed Outdoor Pendant Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N ...

Page 15: ...3 7 RELAY NO Relay normally open TB3 8 RELAY NC Relay normally closed J2 for optional fiber optics interface board that provides video and RS 422 full duplex data through a standard fiber optics connector Wiring Connections Standard Coaxial Fiber Optic Versions CONNECTOR PIN NUMBER CONNECTOR TYPE CONNECTOR PIN LABEL SIGNAL NAME TERMINAL BLOCK VIDEO NVT TB4 TB4 1 UTP Unshielded twisted pair TB4 2 U...

Page 16: ...12 Wiring and Setup XX134 60 01 Rev 108 SurveyorVFT Camera Dome Quick Guide Wiring Connections UTP Version ...

Page 17: ... RJ 45 LAN J7 J7 1 TX Transmit J7 2 TX Transmit J7 3 RX Receive J7 4 POE POWER PoE Power J7 5 POE POWER PoE Power J7 6 RX Receive J7 7 POE POWER PoE Power J7 8 POE POWER PoE Power 1 8 IN PHONO AUDIO J3 MIC Audio In J6 SPK Audio Out N A Wiring Connections ViconNet Version Pin Connections SVFT PRS Customer prepared cable Prefabricated cable On coaxial and UTP units L M X and U are not used On fiber ...

Page 18: ...xial a screw terminal for twisted pair video an ST connector for fiber optic or an RJ 45 connector on the ViconNet board for video connection and a removable two position screw terminal connector for camera power DIP Switch Settings The address and mode are set using the two 8 position DIP Switch banks SW1 and SW2 DIP switch 1 SW1 is used to set the address DIP switch 2 SW2 is used to set the mode...

Page 19: ...part of the preset if the image is out of focus when the preset is stored it will be out of focus when the preset is solved even if autofocus is enabled When a preset is recalled the corresponding preset title is displayed on the screen when preset titles have been enabled If the operator attempts to recall a preset number that has not been stored the message Preset Not Stored appears on the scree...

Page 20: ...f sector 2 Continue panning the camera and pressing AP until all 16 boundaries have been programmed If fewer than 16 sectors are required press AP repeatedly at the right boundary of the last sector you will be programming to use up all the boundary numbers and exit sector programming mode When the camera is moved the corresponding sector title is displayed on the screen when sector titles have be...

Page 21: ...Zoom Scalable Pan Tilt Compass PTZ TImeout and Flip features Camera Controller Permits user adjustment of the advanced video features available on the SurveyorVFT Alarm Handling Configures the SurveyorVFT s four alarm inputs Relay Driver Adjusts and configures the relay output for control of external devices Source Titling Programs and displays the various titles available to the SurveyorVFT Note ...

Page 22: ...y equipment which may have been tampered with altered misused or been subject to unauthorized repair Software supplied either separately or in hardware is furnished on an As Is basis Vicon does not warrant that such software shall be error bug free Software support via telephone if provided at no cost may be discontinued at any time without notice at Vicon s sole discretion Vicon reserves the righ...

Page 23: ...rs Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Germany vin videotronic infosystems gmbh Lahnstrasse 1 D 24539 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 47 Far East Office Unit 5 17 F Metropole Square 2 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...

Reviews: