DIGITAL MULTIMETER OPERATION MANUAL 

 

1. GENERAL 

The instrument is a stable and good performance digital multi-meter driven by 
battery. It uses the LCD with 26mm-high figure to make the reading clear. Unit 
symbol displaying, and the function of backlight and overload protection make 
operation is convenient. 
The instrument has the function of measuring DCV, ACV, DCA, ACA, resistance, 
capacitance, inductance, temperature and frequency, and diode, triode and 
continuity test. The instrument takes dual-integral A/D converter as key point, is an 
excellent tool. 

2. SAFETY 

NOTES 

This series meter, meets the standard of IEC1010. Please read below notes 
carefully before operation. 
1. Do not input a limited voltage which RMS is over DC 1000V or AC 700V when 
measuring voltage. 
2. Voltage less than 36V is a safety voltage. When measuring voltage higher than 
DC 36V, AC 25V, check the connection and insulation of test leads to avoid electric 
shock. 
3. Be sure to keep the test leads off the testing points when converting function and 
range. 
4. Select correct function and range to avoid fault operation. 
5. When measuring current, do not input current over 20A. 
6. Safety symbols 

” exists high voltage, “

” GND, “

” dual Insulation, “

” must refer to manual, 

” low battery. 

3. SPECIFICATION 

1). GENERAL 

1-1. Displaying: LCD displaying. 
1-2. Max. indication: 1999 (3 1/2), auto polarity indication. 
1-3. Measuring method: dual slope A/D transfer. 
1-4. Sampling rate: approx, 3 times/sec. 
1-5. Over range indication: MSD displays “1”/“OL” or “-1”/“OL”. 
1-6. Low battery indication. “

” symbol displays. 

1-7. Operation: (0~40)°C, relative humidity <80%. 
1-8. Power: one 9V battery (NEDA 1604/6F22 or equivalent). 
1-9.  Size: 190

×

88.5

×

27.5mm. 

1-10. Weight: approx. 320g (including a battery). 

 
2). TECHNICAL DATA 
2-1. Accuracy:

 ±(a% 

×

 r dgts) at (23 ± 5)°C, relative humidity<75%. 

One year guarantee since production date. 

2-2. Function: 

DCV Resistance 

 Temperature 

°C 

ACV 

Diode continuity testing 

Frequency f 

DCA 

Triode 

h

FE 

Inductance L 

ACA 

Capacitance C 

Auto power-off 

 

2-3. TECHNICAL DATA 
2-3-1. DC Voltage 

Range 

Accuracy 

Resolution 

200mV 

0.1mV 

2V 

1mV 

20V 

10mV 

200V 

±(0.5%+3) 

100mV 

1000 V 

±(1.0%+5) 

1V 

Input resistance: 10M

 for all ranges. 

Overload protection: Range 200mV: DC 250V or AC peak value. 

Other ranges: DC 1000V or AC peak value. 

 

2-3-2. ACV Voltage 

Range 

Accuracy 

Resolution 

200mV 

±(1.2%+3) 

0.1mV 

2V 

1mV 

20V 

10mV 

200V 

±(0.8%+5) 

100mV 

700V 

±(1.2%+5) 

1V 

Input resistance: It is 1M

 at range 200mV or 2V, and be 10M

 at others. 

Overload protection: DC 250V or AC peak value at range 200mV. 

DC 1000 V or AC peak value at others. 

Frequency response: Range less than 200V: (40~400)Hz. 

Range 700V: (40~100)Hz. 

Displaying: RMS of sine wave (mean value response). 
 

2-3-3. DCA 

Range 

Accuracy 

Resolution 

2mA 

±(0.8%+3) 

1uA 

 

20mA 

±(0.8%+3) 

10uA 

200mA 

±(1.2%+4) 

100uA 

20A 

±(2.0%+5) 

10mA 

Max. measuring voltage drop: 200mV. 
Max. input current: 20A (within 10 seconds). 
Overload protection: 0.2A/ 250V fast-blown fuse, range 20A infused. 
 

2-3-4. ACA 

Range 

Accuracy 

Resolution 

2mA 

1uA 

20mA 

±(1.0%+5) 

10uA 

200mA 

±(2.0%+5) 

100uA 

20A 

±(3.0%+10) 

10mA 

Max. measuring voltage drop: 200mV. 
Max. input current: 20A (within 10 seconds). 
Overload protection: 0.2A/250V fused, range 20A infused. 
Frequency response: (40~200)Hz. 
Displaying: RMS of sine wave (mean value response). 
 

2-3-5. RESISTANCE (

Range 

Accuracy 

Resolution 

200

 

±(0.8%+5) 

0.1

 

2k

 

1

 

20k

 

10

 

200k

 

100

 

2M

 

±(0.8%+3) 

1k

 

20M

 

±(1.0%+l5) 

10k

 

2000M

 

±[5%(reading-10)+20] 

1M

 

Open voltage: less than 3V. 
Overload protection: DC 250V or AC peak value. 

NOTE:

 A: At range 200

, short-circuit the test leads to measure the wire resistance, then, 

subtracts it from the real measurement. 
B: At range 200M

, when the test leads short circuit, LCD displays 1.0M

. In the same way, 

the reading is 10M

 while the test leads short at range 2000M

. It’s normal and doesn’t 

affect the accuracy Please deduct the value from the real measurement. 
C: The reading be displayed slowly when the measurement is more than 1M

Please wait it to be stable. 
 

2-3-6. Capacitance 

Range 

Accuracy 

Resolution 

20nF 

10pF 

200nF 

100pF 

2uF 

1nF 

20uF 

±(2.5%+20) 

10nF 

200uF 

±(5.0%+5) 

100nF 

Test frequency: 100Hz. 
Overload protection: DC 36V or AC peak value. 
 

2-3-7. Inductance (L) 

Range 

Accuracy 

Resolution 

2mH 

1uH 

20mH 

10uH 

200mH 

100uH 

2H 

1mH 

20H 

±(2.5%+20) 

10mH 

Test frequency: 100Hz. 
Overload protection: DC 36V or AC peak value. 

 
2-3-8. Temperature 

Range 

Accuracy 

Resolution 

(-40~1000)°C 

±(0.8%+4) < 400°C 

±(1.5%+15) 

 400°C 

1°C 

K-type thermocouple (banana-shape plug). 
 

2-3-9. Frequency 

Range 

Accuracy 

Resolution 

2kHz 

1Hz 

20kHz 

10Hz 

200kHz 

100Hz 

2000kHz 

1kHz 

10MHz 

±(0.5%+4) 

10kHz 

Input sensitivity: 1V RMS. 
Overload protection: DC 250V or AC peak value (within 10 seconds). 