Instructio

ns

1 of 3

The Viega LLC Pump and Boiler Relay provides power to 

circulators and can enable a boiler as well.  Control may be 

provided from a Viega Zone Control or Thermostat.

Features

•  External Indicator Lights

•  Universal Replaceability

•  Snap-in PC Board

•  Simple Wiring

•  Sealed Relays

•  Fuse Protected Outputs

•  100% Factory Tested

•  Contractor Friendly PC Board Layout

•  Universal Zone Control and Thermostat Compatibility

•  UL Approved

Specifications

T

ransformer Voltage:120 VAC input

Input Voltage: 120/60/1 VAC
Maximum Combined Load: 12 Amps
Relay Connections: 1/3 hp ( 6FLA, 36 LRA )@ 120 vac
Thermostat Connection: 24 VAC Class 2 Output

Installation

Wiring connections must be made in accordance with all 

applicable electrical codes.  Use copper wire only.  Failure to 

follow this instruction can result in personal injury or death and/

or property damage.  12-18 gauge wire recommended for all 120 

VAC connections with 9 in. lbs. max torque, 14-22 gauge wire for 

thermostat connections with 9 in. lbs. max torque. 120VAC wiring 

must have a minimum temperature rating of 75

°

C.

Jumper placement:

 

The jumper is factory installed between terminals H and 3 to 

switch power on terminals 4 n/o and 4 n/c.

Operation

There are four common ways to connect the Pump and Boiler 

Relay:

Wiring Diagram #1 Viega Digital Thermostat 

(stock code 18050):

From the thermostat connect the R, W and C terminals to the 

corresponding R, W and C terminals on the zone control. When 

the thermostat calls for heat, the relay in the zone control is 

energized and power is supplied to the circulator. 

(R=R, W=W, C=C)

Wiring Diagram #2 Viega analog style thermostat 

(stock code 18029, 18031):

From the thermostat connect the L terminal to the R terminal on 

the zone control, connect the    to the W terminal on the zone 

control, and connect the N to the C terminal on the zone control. 

When the thermostat calls for heat, the relay in the zone control 

is energized and power is supplied to the circulator. 

(L=R,   =W, N=C)

Wiring Diagram #3 Zone Control:

Connect pump relay contacts of Zone Control to “T T” terminals 

on the relay.  When the Zone Control calls for heat, the relay is 

energized and power is provided to the circulator (and/or dry 

contact to the boiler).  

Wiring Diagram #4 With 2-Wire Thermostat:

Connect a 2-wire thermostat to the “T T” terminals on the 

relay.  When the thermostat calls for heat, the relay is energized 

and power is provided to the circulator (and/or dry contact to 

the boiler).  

Dimensions

Width   4-7/8"

Height  5-5/8"

Depth   2-3/8"

Troubleshooting

The external indicator lights show full functionality of the Pump 

and Boiler Relay.  The green light should always be on, indicating 

that power is connected.  If the green light is out check the 

power connections at terminals N and H.

The red light shows a call for heat, indicating that power is 

being supplied to the circulator (and/or a boiler enable signal is 

provided). 

If the Zone Control or thermostat is calling for heat but the red 

light is out, check the thermostat wiring.  If the red light is on but 

the circulator is not running, check the circulator connection to 

the relay.