Viega LLC
585 Interlocken Blvd.
Broomfield, CO 80021
Phone (800) 976-9819
www.viega.us
Product Instructions
Viega PureFlow
®
Fire Rated
Outlet Boxes
PI-PF 599986 1119 PureFlow Fire Rated Outlet Boxes (EN ES FR)
Models 2872.2, 2872.3, 2872.5, 2872.6
EN
Product Instructions
Viega PureFlow Fire Rated
Outlet Boxes
This document is subject to updates. For the most current Viega
technical literature please visit www.viega.us.
6
A
C
B
D
F
H
E
G
Pure
Flow
1/2”
Pure
Flow
1/2”
Pure
Flow
1/2”
1
7
8
3
2
9
4
10
11
12
5
6
EN
Viega PureFlow Fire Rated Outlet
Boxes
For Washing Machine and Icemaker Boxes
Viega products are designed to be
installed by licensed and trained plumbing
and mechanical professionals who are
familiar with Viega products and their installation.
Installation by non-professionals may void
Viega LLC’s warranty.
Assembly tested to ASTM 814.
Product certified for both metal and wood
studs.
1
A. Stud
B. Face plate
C. Backing board fastened between studs
D. Valve outlet
E. Solvent cement drain connection
F. Viega PureFlow press
G. PureFlow tube
H. Wall material
2
If installing the washing machine box, clip the
mounting brackets into the box (the icemaker box
has built in mounting brackets). Position the box
between studs at the desired height.
3
Use two nails or screws per bracket to secure
the outlet box to the front of the studs. On the
washing machine boxes, if necessary, cut or
punch opening on the bottom of the box for the
2" plastic drain tube and solvent cement tube
connection.
4
Prepare PureFlow tubing by squaring off to proper
length. Uneven, jagged, or irregular cuts will
produce unsatisfactory connections.
5
Insert PureFlow tubing into the attached PureFlow
press sleeve on the valve(s).
6
Ensure that the tube is fully inserted by visually
confirming that is appears in the view holes in
PureFlow press sleeve. Full insertion means tubing
must be completely visible in at least two view
holes and partially visible in the one.
7
Position the PureFlow press tool perpendicular
over the press sleeve, resting it against the tool
locator ring. Make sure the PureFlow press tool is
properly aligned (see step 9 if it is not).
For a one or two hour fire rating, the
Fire Rated box must be installed in the
corresponding Gypsum board. The wall
cavity must have a minimum 3½" cavity depth.
Store Fire Rated outlet boxes in a cool, dry
place and out of direct sun exposure.
WARNING!
Do not install two boxes back to back.
WARNING!
The connection is not leakproof when
the tool has been opened by emergency
release. The tool locator ring must be present to
ensure a proper PureFlow Press connection.
CAUTION!
Do not press twice!
The tool locator ring must be in the factory
installed position while making a press to
ensure a consistent leakproof connection.
It may be necessary to rotate the tool locator ring
to avoid interference between the ring and tool.
8
Close the PureFlow press tool handles, using the
trigger to reduce the grip span if desired.
9
If the PureFlow press tool is not properly aligned
with the locator ring, use the emergency release
(using a screw driver to turn the emergency
release) to open the press tool. Once released,
align the PureFlow press tool properly and go
back to step 7.
10
Extend the PureFlow press tool handle and
continue ratcheting until automatic tool release
occurs at the proper compression force.
11
When installing drywall, cut an opening (8¼" W x
6
3
/
16
" H for the washing machine box and 3
15
/
16
" W
x 5
5
/
16
" H for the icemaker box). Any gap between
the drywall and the side of the box must be filled
with drywall compound.
12
Push face plate into the box until the plate is flush
against the wall material.
ES
Instrucciones del producto
Cajas de salida con clasificación
contra incendios Viega PureFlow
Este documento está sujeto a actualizaciones. Para obtener la
documentación técnica más reciente de Viega, visite www.viega.us.
FR
Instructions produit
Boîtes de sortie résistantes au feu
Viega PureFlow
Le présent document est soumis à des mises à jour. Pour consulter
les manuels techniques Viega les plus récents, veuillez visiter
www.viega.us.