Installation instructions

for contractors

VIESMANN

Vitoplanar EI2
Type EI2.A1000GW and EI2.A1500GW

Infrared heater

VITOPLANAR EI2

5855607 GB

2/2018

Summary of Contents for EI2.A1000GW

Page 1: ...Installation instructions for contractors VIESMANN Vitoplanar EI2 Type EI2 A1000GW and EI2 A1500GW Infrared heater VITOPLANAR EI2 5855607 GB 2 2018 ...

Page 2: ...r have been instructed in the safe use of this appliance and any risks arising from it Regulations to be observed National installation regulations Statutory regulations for the prevention of accidents Statutory regulations for environmental protection Codes of practice of the relevant trade associations All current safety regulations as defined by DIN EN DVGW TRGI TRF VDE and all locally applicab...

Page 3: ...ug the appliance into a wall socket regulate the appliance clean the appli ance or carry out maintenance The appliance may only be commissioned once it has been installed The appliance must not be used in the immediate vicinity of a bathtub shower or swimming pool The appliance must not be used in small rooms inhabited by persons who cannot leave the room independently unless constant monitoring i...

Page 4: ...a tion in conjunction with permissible components designed for this purpose has been carried out The appliance should be able to radiate freely into the room The appliance must not be used in the immediate vicinity of a bathtub shower or swimming pool All other use is deemed inappropriate Any resulting losses are excluded from the manufacturer s liability Any usage beyond this must be approved by ...

Page 5: ... Please note Installation on uneven surfaces can cause dam age to the heating surface due to stress Only fit the appliance to level walls Standard delivery for wall mounting Fig 1 Fixing parts 2 x eccentric discs 1 x cable clip self adhesive Clearance dimensions Fig 2 Minimum clearances Danger Operating the appliance with insufficient clear ances may result in flammable objects catching fire Obser...

Page 6: ...ddenly Only use screws and rawl plugs that are suitable for the type of wall masonry con crete plasterboard etc Fig 4 3 Align the eccentric discs horizontally and tighten the screws Fig 5 4 Secure the self adhesive cable clip to the bottom of the metal frame at the rear of the appliance Note The position of the cable clip should be appropriate for the power supply Fig 6 5 Connect the appliance See...

Page 7: ... you hear a met allic noise Hole spacings Fig 9 Electrical connection Danger Incorrect wiring can lead to serious injury from electrical current and result in appliance dam age Connection to wall junction boxes must only be carried out by qualified contractors Danger A damaged connecting cable can lead to electric shock and short circuit Check the connecting cable for damage before installation Mo...

Page 8: ...orrectly connect the supplied connecting cable with plug to the junction box Note The connecting cable can be extended with a cable of type H05VV F3G 1 5 mm A direct connection to the appliance is not possi ble Commissioning and instructing the user Commissioning and user instruction must be carried out by the contractor performing the installation The operator must be instructed as to how the rad...

Page 9: ...ulations of the directive on the environmentally sound design of energy related products ErP Final decommissioning and disposal Viessmann products can be recycled Components and substances from the system are not part of ordi nary household waste For decommissioning the system isolate the system from the power supply and allow components to cool down where appropriate All components must be dispos...

Page 10: ...onwood 30 Telford Shropshire TF1 7YP GB Telephone 44 1952 675000 Fax 44 1952 675040 E mail info uk viessmann com Viessmann Werke GmbH Co KG D 35107 Allendorf Telephone 49 6452 70 0 Fax 49 6452 70 2780 www viessmann com 5855607 ...

Page 11: ...11 5855607 ...

Page 12: ... Shropshire TF1 7YP GB Telephone 44 1952 675000 Fax 44 1952 675040 E mail info uk viessmann com Viessmann Werke GmbH Co KG D 35107 Allendorf Telephone 49 6452 70 0 Fax 49 6452 70 2780 www viessmann com 5855607 Subject to technical modifications ...