background image

Installation and service

instructions

for contractors

VIESMANN

Vitogate 200
Type EIB

Communication for heating systems via KNX/EIB systems

For applicability, see the last page

VITOGATE 200

5592 880 GB

6/2007

Please keep safe.

Summary of Contents for Vitogate 200

Page 1: ...n and service instructions for contractors VIESMANN Vitogate 200 Type EIB Communication for heating systems via KNX EIB systems For applicability see the last page VITOGATE 200 5592 880 GB 6 2007 Please keep safe ...

Page 2: ...f accidents all legal instructions regarding envi ronmental protection the Code of Practice of relevant trade associations all current safety regulations as defined by DIN EN DVGW TRGI TRF VDE and all locally applicable standards Gas Safety Installation Use Regu lations the appropriate Building Regulation either the Building regulations the Building Regulation Scotland Building Regulations Norther...

Page 3: ...static dis charges Touch earthed objects such as heating or water pipes to dis charge static loads Repair work Please note Repairing components which ful fil a safety function can compro mise the safe operation of your heating system Replace faulty components only with original Viessmann spare parts Ancillary components spare and wearing parts Please note Spare and wearing parts which have not bee...

Page 4: ...2 Vitotronic control unit LON integration 12 EIB product database 14 Communication objects and flags 15 Parameters in ETS 18 Troubleshooting BUS voltage mains power failure 26 Characteristics after restoration of BUS voltage mains power 26 Connection fault between the Vitogate 200 and the EIB or LON system 26 Designs Connection diagram 27 Specification 28 Certificates Declaration of conformity 29 ...

Page 5: ...totronic 200 H type HK1M Vitotronic 050 type HK1M Vitotronic 200 H type HK1S HK3S Vitotronic 050 type HK1S HK3S Vitotronic 200 H type HK1W HK3W Vitotronic 050 type HK1W HK3W Vitotronic 100 type GC1 Vitotronic 200 type GW1 Vitotronic 300 type GW2 Vitotronic 300 K type MW1 MW1S Vitotronic 333 type MW1 MW1S Functions The Vitogate 200 type EIB enables sys tem users to utilise the following func tions ...

Page 6: ... within one LON Cable types on site 2 core cable CAT 5 screened JY St Y 2 x 2 x 0 8 mm telephone cable Observe the cabling requirements for the operation of the LON interface FTT 10A see www echelon com All Viessmann LON devices are connected via RJ45 plugs The Viessmann LON always requires cores 1 and 2 plus the screen The cores are interchangeable The installation is therefore reverse polarity p...

Page 7: ...e 7 m long Connection with LON cable and LON coupling C E A A B E D D D E E D D C D Routing distance 7 to 21 m A Vitotronic control unit B Vitogate 200 type EIB C Terminator D LON cable 7 m long Max 3 cables between 2 applian ces E LON coupling Installation sequence Connection to the Vitotronic control unit cont 5592 880 GB Installation ...

Page 8: ... On site cable F Up to 99 subscribers Connection with LON cable on site cable and LON socket 900 m F C D C D D D E F F F E A A G B Routing distance 900 m with LON sockets A Vitotronic control unit B Vitogate 200 type EIB C Terminator D LON cable 7 m long E On site cable F LON sockets G Up to 99 subscribers Installation sequence Connection to the Vitotronic control unit cont 5592 880 GB ...

Page 9: ...6 or local reg ulations Fit the main isolator outside the installa tion room It must be able to isolate all non earthed conductors simultaneously with at least 3 mm contact separation Power supply via the main isolator When the heating system is switched off via the main isolator the Vitogate 200 type EIB and the Vitotronic control unit are also switched off No data is transferred to the EIB sys t...

Page 10: ...otronic con trol unit Colour coding to DIN IEC 60757 BN brown BU blue GNYE green yellow Power supply independent of the main isolator When the heating system is switched off via the main isolator the Vitogate 200 type EIB remains on whilst the Vitotronic control unit is switched off No data is transferred to the EIB sys tem L1 PE N B C 40 D A L1 N F N L E BN BU GNYE A Vitogate 200 type EIB B Power...

Page 11: ...ion 2 Connect the power cable on site inside junction box D and at plug fÖ Danger Incorrect core termination can cause severe injuries and damage to the appliance Never interchange cores L1 and N L1 brown N blue PE green yellow 3 Insert plug fÖ into the Vitotronic con trol unit Installation sequence Power supply cont 5592 880 GB Installation ...

Page 12: ... yellow orange Vitotronic control unit LON integration The LON communication module accessory must be plugged into the Vitotronic control unit Note The data transfer via the LON system can take several minutes Viessmann system number and subscriber number Set LON system number LON sub scriber number and further functions via code 2 Vitotronic control unit service instructions and the following tab...

Page 13: ...er Viessmann system num ber Code 98 1 Viessmann system num ber Code 98 1 LON subscriber fault mon itoring Code 9C 20 LON subscriber fault mon itoring Code 9C 20 Updating LON subscriber list Preconditions All subscribers must be connected The control unit must be programmed as fault manager code 79 1 Press the following keys 1 L d simultaneously for approx 2 s The subscriber check has been initiate...

Page 14: ...ashes until its completion The display and all backlit keys for the selected subscriber flash for approx 60 s 4 Check OK is displayed during com munication between both devices Check not OK is displayed if there is no communication between both devices Check the LON connection and encoding 5 Repeat points 2 and 3 to check further subscribers 6 L d simultaneously for approx 1 s The subscriber check...

Page 15: ...only or write enabled via the Vitogate 200 type EIB If the write flag is deleted for a datapoint then it can no longer be written to via the EIB system although this would be possible via the Vitogate 200 type EIB Datapoints are assigned to every Vitotronic control unit Subject to the parameter settings the associated data point list will be available in a pop up menu A list of every available dat...

Page 16: ...iebsart EIS6 20 Betriebsart EIS6 A1 Betriebsart EIS6 21 Betriebsart EIS6 A1 Betriebsart EIS6 22 Betriebsart EIS6 A1 Betriebsart EIS6 23 Betriebsart EIS6 A1 Betriebsart EIS6 24 Betriebsart EIS6 A1 Betriebsart EIS6 25 Betriebsart EIS6 A1 Betriebsart EIS6 26 Betriebsart EIS6 A1 Betriebsart EIS6 27 Betriebsart EIS6 A1 Betriebsart EIS6 28 Betriebsart EIS6 A1 Betriebsart EIS6 29 Betriebsart EIS6 A1 Betr...

Page 17: ...on Kommunikation Com munication Authority for communication with EIB system corresponds to a main switch Lesen Read Read request via EIB system if the group address in this communication object stands in first position Schreiben Write Authority to write via the EIB system Commissioning Communication objects and flags cont 5592 880 GB Service ...

Page 18: ...owing a power failure Parameters in ETS With the Vitogate 200 type EIB up to 32 communication objects can be pro cessed by the Vitotronic control units in the EIB system connected via LON The heating system fault messages are transferred in the form of an error bit and or an error byte Commissioning Communication objects and flags cont 5592 880 GB ...

Page 19: ...Subscriber number 4 Dienst Service 5 Gruppe Group 6 Datenpunkt Data point 7 Zykluszeit Cycle time 8 max Abweichung gegenüber zuletzt gesendeten Wert max deviation from the value transmitted last 1 Regelung Menu for the selection of the Vitotronic control unit to be assigned to the corre sponding communication object Commissioning Parameters in ETS cont 5592 880 GB Service ...

Page 20: ... type HO1 VPendHO1 Vitotronic 200 type HO1 2 Anlagen Nummer Menu for the selection of the Viessmann system number to be assigned to the corresponding communication object Menu selection 1 to 5 If several systems are connected to a LON a number is assigned to each sys tem Up to 5 systems are possible A system may comprise up to 4 boilers up to 32 heating circuit control units and 1 cas cade control...

Page 21: ...ut of the operating parameters for heating circuit M2 e g operating modes subject to the Vitotronic control unit assigned under Regelung Bedienung M3 Opera tion M3 Input of the operating parameters for heating circuit M3 e g operating modes subject to the Vitotronic control unit assigned under Regelung Information Service scans for actual values and conditions tempera tures operating status of pum...

Page 22: ...ogate 200 eib 7 Zykluszeit Menu for the selection of the transmis sion interval to be assigned to the corre sponding communication object Menu selection Explanation 5 s bis 120 min 5 s to 120 min The value of this datapoint is transmitted cyclically to the EIB system in accordance with the selected interval nicht zyklisch senden do not transmit cycli cally The value of this datapoint is either nev...

Page 23: ...the set percent age Error bit central fault message Example with ETS3 Any fault on a component of the heating system can trigger the transmission of a Fehlerbit Sammelstörung error bit cen tral fault message to an appropriate cen tral fault message facility However this requires the fault message to be actually captured by the Vitotronic control unit You can select the transmission inter val Zyklu...

Page 24: ...he higher the BUS load for example see page 22 Max Abweichung Max deviation Menu for the selection of the transmis sion interval subject to the setting of the cycle time Menu selection Explanation nie senden Never transmit The fault message is never transmitted to the EIB sys tem bei jeder Änderung sen den transmit after every change The fault message is transmitted to the EIB system follow ing ev...

Page 25: ... Menu selection Explanation 5 s bis 120 min 5 s to 120 min The fault message is transmitted cyclically to the EIB sys tem in accordance with the selected interval nicht zyklisch senden do not transmit cycli cally The fault message is either never transmitted to the EIB system or only in the case of a change Note The shorter the cycle time the higher the BUS load for example see page 22 Max Abweich...

Page 26: ...fter the BUS voltage mains power has been restored again Connection fault between the Vitogate 200 and the EIB or LON system EIB system If the connection between the Vito gate 200 and the EIB system is interrup ted fault code 98 will be displayed on the Vitotronic control unit designated as fault manager LON system No data will be transferred to the EIB system if a LON subscriber e g Vitotronic co...

Page 27: ...onnection 2 pce RJ45 sockets screened B EIB 28 V connection 2 Wago solder pins part no 243 131 for fitting the Wago EIB terminal C 230 V power supply 2 pole terminal Type Phoenix MKDSP3 2 5 08 Designs Connection diagram 5592 880 GB Service ...

Page 28: ...tion Function Type 1 B as per EN 60730 1 Permiss ambient tempera ture during operation 0 to 70 C Installation in living spaces or boiler rooms standard ambient conditions during storage and trans port 20 to 85 C Humidity Humidity load to EN 60721 75 annual average 95 30 days continuous 85 remaining days occasionally Specification Specification 5592 880 GB ...

Page 29: ...IN EN 50090 2 2 1997 06 DIN EN 61000 6 2 2002 08 DIN EN 55024 2003 10 DIN EN 61000 6 3 2005 06 DIN EN 55014 1 2003 09 DIN EN 55014 2 2002 08 This product is _ designated in accordance with the terms of the following Direc tives 89 336 EEC Allendorf 01 June 2007 Viessmann Werke GmbH Co KG pp Manfred Sommer Certificates Declaration of conformity 5592 880 GB Service ...

Page 30: ...ng key 12 EIB system ON indicator 12 Electrical connections EIB 27 LON 27 Overview 27 Power supply 9 27 Error bit 23 Error byte 24 ETS 18 Download 15 F Fault manager 13 Flags 15 Explanation 17 Read 17 Write 17 G Group 21 L LON Cable 7 Connection to Vitotronic control unit 6 Control unit integration 12 Coupling 7 Electrical connections 27 Fault monitoring 13 ON indicator 12 On site 8 Plug 8 Service...

Page 31: ...t 22 Power supply Guidelines 9 Independent of main isolator 10 Via main isolator 9 Power supply regulations 9 Product database 14 R Reset 12 S Service 21 Standard setting 12 Status display EIB system 12 Subscriber number 20 System number 20 T Transmission interval 22 23 25 V Vitotronic 5 Keyword index Keyword index cont 5592 880 GB ...

Page 32: ... Limited Hortonwood 30 Telford Shropshire TF1 7YP GB Telephone 44 1952 675000 Fax 44 1952 675040 E mail info uk viessmann com Viessmann Werke GmbH Co KG D 35107 Allendorf Telephone 49 6452 70 0 Fax 49 6452 70 2780 www viessmann com 5592 880 GB Subject to technical modifications Printed on environmentally friendly chlorine free bleached paper ...

Reviews: