background image

Operating instructions

for the system user

VIESMANN

Wireless remote control for one, two or three heating circuits

VITOTROL 300 RF

5592 245 GB

4/2012

Please keep safe.

Summary of Contents for VITOTROL 300 RF

Page 1: ...Operating instructions for the system user VIESMANN Wireless remote control for one two or three heating circuits VITOTROL 300 RF 5592 245 GB 4 2012 Please keep safe ...

Page 2: ...person as to how to use the unit Please note Children should be supervised Ensure that children do not play with the unit Danger Incorrectly executed work on the heating system can lead to life threatening accidents Work on gas appliances must only be carried out by a regis tered gas fitter Work on electrical equipment must only be carried out by a qualified electrician If you smell gas Danger Esc...

Page 3: ...ra tion at risk Ensure ambient temperatures above 0 ºC and below 35 ºC Prevent air contamination by halogenated hydrocarbons e g as contained in paints solvents or cleaning fluids and excessive dust e g through grinding polishing work Avoid continuously high humid ity levels e g through frequent drying of washing Never close existing ventilation apertures Ancillary components spare and wearing par...

Page 4: ...Central heating Required settings central heating 18 Selecting a heating circuit 18 Setting the room temperature 19 Setting the room temperature for standard heating mode 19 Setting the room temperature for reduced heating mode night setback 19 Setting the operating program for central heating 20 Setting the time program for central heating 20 Setting a time program for a day 21 Adopting the time ...

Page 5: ...ttings 33 Scanning Scanning information 35 Scanning in conjunction with solar thermal systems 35 Scanning the field strength 35 Resetting data to zero 36 Scanning the service messages 36 Calling up an acknowledged service message 37 Scanning fault messages 37 What to do if Rooms are too cold 39 Rooms are too hot 39 There is no hot water 40 The DHW is too hot 40 ã flashes and Fault is displayed 40 ...

Page 6: ...6 Appendix Menu overview 46 Extended menu see page 46 Scanning options in the extended menu 47 Terminology 47 Keyword index 51 Index Index cont 5592 245 GB ...

Page 7: ...ing is enabled for the boiler and DHW cylinder room tem perature for reduced heating mode 3 C Your heating contractor can make fur ther adjustments for you during com missioning You can change any settings individu ally at any time to suit your require ments see chapter Central heating from page 18 DHW heating Between 05 30 and 22 00 h the DHW is heated to 50 C Any installed DHW circulation pump i...

Page 8: ... Economy mode see page 23 As long as economy mode is activa ted the room temperature is reduced If you are going away set the Hol iday program see page 24 As long as the holiday program is activated the room temperature is reduced and DHW heating is off In summer if you don t want to heat any rooms but do need DHW select the operating program Only DHW see page 26 If you do not want to heat any roo...

Page 9: ...its table top dock or wall mounting bracket This ensures that the batteries are always charged The Vitotrol 300 RF enables the follow ing adjustments to be made from the liv ing space Standard room temperature Reduced room temperature DHW temperature Operating and holiday program Time phases for central heating Time phases for DHW heating Time phases for the DHW circulation pump if installed Date ...

Page 10: ...r the boiler and DHW cylinder Central heating with standard room temperature Central heating with reduced room temperature In conjunction with a solar thermal system Solar circuit pump is running Wireless connection transmitting icon Transmission and reception quality of the wireless connection Very good Good Adequate Inadequate In addition an acoustic signal will sound every 10 s and Poor wire le...

Page 11: ...em Standby mode Only DHW DHW and heating Standard menu There are two control levels available the standard menu see the following chapter and the extended menu see page 13 You can scan and adjust the settings you use most frequently from the standard menu Set room temperature Operating program Heating circuit selection Comfort function Party mode Energy saving function Economy mode Call up the sta...

Page 12: ...ram Holiday program If the Vitotrol 300 RF is not in its table top dock or wall mounting bracket Mobile test location Weak batt charge Poor wireless conn Adjusting the set room temperature for the displayed heating circuit Press the following buttons for the required value OK to confirm Selecting the operating program for the displayed heating circuit 1 Press the following buttons or or depending ...

Page 13: ...ction Economy mode Press The button becomes lighter Enabling comfort function Party mode Press the following buttons for the required temperature in party mode OK to confirm The button becomes lighter Extended menu In the extended menu you can adjust and scan the settings from the remote control s range of functions used less frequently e g holiday program and time programs The menu overview can b...

Page 14: ...display brightness is reduced 14 20 5 B C B Outside temperature C Current room temperature 1 Touch the display This takes you to the standard menu see page 11 2 Press Menu This takes you to the extended menu see page 13 The following example shows how to adjust the set room temperature for heat ing circuit 1 and heating circuit 2 About the controls Extended menu cont 5592 245 GB ...

Page 15: ...t 2 Menu 14 20 5 Heating circuit 1 Wednesday 25 05 2011 13 42 Heating circuit 1 Menu 14 22 22 Adopted Set room temperature Heating circuit 1 OK Set room temperature Heating circuit 1 OK 22 Set room temperature Heating circuit 1 20 5 OK 4 s Menu About the controls How to use the controls cont 5592 245 GB ...

Page 16: ...racket always remember to replace it once you have finished to allow the batteries to be charged and maintain good reception The batteries will last for approximately 3 h Table top dock 1 2 Note Make sure that the power plug is con nected Start up shutdown Charging the batteries 5592 245 GB ...

Page 17: ...17 Wall mounting bracket 1 2 Start up shutdown Charging the batteries cont 5592 245 GB ...

Page 18: ... you are using your remote control to control several heating circuits for all central heating settings first select the heating circuit for which you want to make a change If you are only controlling one heating circuit this option is not available Example Heating circuit 1 is the heating cir cuit for the rooms occupied by you Heating circuit 2 is the heating cir cuit for the rooms of a separate ...

Page 19: ... circuit 3 2 for the required value 3 OK to confirm Setting the room temperature for reduced heating mode night setback Factory setting Vitotronic control unit 3 C Extended menu 1 Menu 2 Heating 3 Heating circuit 1 Heating circuit 2 or Heating circuit 3 4 Red set room temperature 5 for the required value 6 OK to confirm The rooms are heated to this tempera ture Between the time phases for standard...

Page 20: ...central heating Factory setting Vitotronic control unit A time phase is set for every day of the week from 06 00 to 22 00 h for rooms to be heated to 20 C room temperature for standard heating mode The time program for central heating is made up of 1 to 4 time phases In the Extended menu you can scan the current time program under Infor mation see page 35 The time program can be set individ ually ...

Page 21: ... Heating circuit 1 OK Start End 05 30 09 00 Time phase 1 1 Saturday 8 OK to confirm 9 If required repeat steps 6 to 8 for fur ther time phases for the selected day of the week Example with 2 time phases for Sat urday Heating time program Saturday Copy 05 30 09 00 16 30 22 00 Heating circuit 1 Standard Standard Note If you want to terminate the setting proc ess prematurely keep pressing until the r...

Page 22: ...pt Mo Tu OK Th We Fr Sa Su 8 OK to confirm Deleting a time phase Set the time for the end point to the same time that was set for the start point The display shows the selected time phase Stopping the central heating Standard menu 1 Heating circuit 1 Heating circuit 2 or Heating circuit 3 2 3 Select the operating program Only DHW summer mode no cen tral heating or Standby mode frost protection mon...

Page 23: ...ng the party mode com fort function Party mode will terminate if you press again the button darkens or automatically after 8 hours this time period can be changed by your heating contractor or automatically when the next time phase in the time program starts see page 13 or if you enable the Economy mode energy saving function Selecting the Economy mode energy saving function To save energy you can...

Page 24: ...y program The holiday program applies to all heat ing circuits If you want to change this contact your local heating contractor Depending on the operating program selected see page 20 the holiday pro gram can have various effects If operating program Heating and DHW is selected The rooms are heated to the selected reduced room temperature see page 19 DHW heating is off If operating program Only DH...

Page 25: ... day of return Wednesday 25 05 2011 13 42 Heating circuit 1 Menu 14 20 5 Holiday program Terminating or deleting a holiday pro gram Extended menu 1 Menu 2 Heating 3 Holiday program 4 Delete holiday program 5 OK to confirm Comfort and energy saving functions Selecting the Holiday program energy saving function cont 5592 245 GB ...

Page 26: ...50 C Extended menu 1 Menu 2 DHW 3 Set DHW temperature 4 for the required value 5 OK to confirm Setting the operating program for DHW heating Factory setting Vitotronic control unit Heating and DHW Note DHW heating applies to all heating cir cuits If you want to change this contact your local heating contractor Standard menu 1 Heating circuit 1 Heating circuit 2 or Heating circuit 3 2 or or dependi...

Page 27: ...35 Automatic can be selected for DHW heating This means that in standard heating mode see page 13 the DHW is reheated to the set tem perature To ensure that hot water is available at the start of standard heat ing mode the time phase for DHW heating automatically begins half an hour earlier than the time phase for standard heating mode If you don t want automatic mode you can select Individual and...

Page 28: ...se Heating circuit 1 OK Start End 05 30 09 00 Time phase 1 1 Saturday 9 OK to confirm 10 If required repeat steps 7 to 9 for further time phases for the selected day of the week Example with 2 time phases for Sat urday Time program DHW Saturday Copy 05 30 09 00 Heating circuit 1 Standard Standard 10 00 12 00 Note If you want to terminate the setting proc ess prematurely keep pressing until the req...

Page 29: ...he display shows the selected time phase One off DHW heating outside the time program Note At least one heating circuit of your sys tem must not be in the operating pro gram Standby mode Standard menu 1 Heating circuit 1 Heating circuit 2 or Heating circuit 3 2 for Party mode 3 Press OK twice to confirm The button becomes lighter 4 to disable Party mode to prevent unintentional central heating wit...

Page 30: ...ulation 4 Individual 5 OK to confirm 6 for the required day of the week e g Saturday 7 Select the required time phase e g 1 05 30 22 00 8 for the required Start and End of the relevant time phase 9 OK to confirm 10 If required repeat steps 7 to 9 for further time phases for the selected day of the week Note If you want to terminate the setting proc ess prematurely keep pressing until the required ...

Page 31: ...am is active 3 Select the operating program Standby mode frost protection monitoring 4 OK to confirm Standard menu 1 Heating circuit 1 Heating circuit 2 or Heating circuit 3 2 or or depending on which op erating program is active 3 Select the operating program Heating and DHW 4 OK to confirm 5 Menu 6 DHW 7 Set DHW temperature 8 Adjust in steps of 10 C 9 OK to confirm DHW heating Stopping DHW heati...

Page 32: ...date Setting the date Extended menu 1 Menu 2 Settings 3 Time Date 4 Date 5 for the required date Date Day Month Year We 11 05 2011 OK 6 OK to confirm Setting the time Extended menu 1 Menu 2 Settings 3 Time Date 4 Time 5 for the required time Time Hours Minutes 15 08 OK 6 OK to confirm Further adjustments Setting the date and time 5592 245 GB ...

Page 33: ...the brightness for the standard display using Standby illumi nation Extended menu 1 Menu 2 Settings 3 Display settings 4 Set the required brightness for the Backlighting 5 Set the required brightness for the Standby illumination Display settings OK Backlighting Standby illumination 90 50 Restoring factory settings You can reset the factory settings of all modified values for each heating circuit s...

Page 34: ... Set room temperature Reduced room temperature Set DHW temperature Operating program Time program for central heating Time program for DHW heating Time program for DHW circulation pump Party mode is terminated Economy mode is terminated Holiday program is terminated or deleted Further adjustments Restoring factory settings cont 5592 245 GB ...

Page 35: ...tems Extended menu 1 Menu 2 Solar energy The solar energy yield for the past 7 days is displayed on a graph The flashing line on the graph indicates that the current day is not yet over Solar energy Tu We Th Fr Sa Su Mo Tu Tuesday 22 03 2011 3 8kWh 0 2 0 4 0 To scan the solar energy yield for a pre vious day tap on the bar of the day you would like to scan Note Further scanning options e g for the...

Page 36: ...e service messages If your heating system is due for a serv ice the symbol flashes in the display and Service appears 1 Pressing OK allows you to access general service information 2 You can call up the reason for the service with OK Service Burner 05500h OK 3 Pressing calls up information on the service that is due 4 If you want to acknowledge the serv ice message press OK The service message is ...

Page 37: ...on the cause of the fault please refer to the operating instructions for the Vitotronic control unit 3 Remember to make a note of the fault code In this example Fault 18 and Fault 20 This enables the heating contractor to be better prepared for the service call and may save additional travelling costs 4 If you want to acknowledge the fault message press OK The fault message is transferred to the F...

Page 38: ...e the signalling will be stopped when you acknowledge the fault message If the fault cannot be rectified until a later date the fault message will be displayed again the next day The signalling equipment will be switched on again Calling up an acknowledged fault message Extended menu 1 Menu 2 Fault Scanning Scanning fault messages cont 5592 245 GB ...

Page 39: ... oil LPG Check the fuel reserves and re order if required With natural gas Open the gas shut off valve If necessary check with your gas supply utility Fault is displayed Scan and acknowledge the type of fault see page 37 If necessary notify your heating contractor Rooms are too hot Cause Remedy Remote control is incorrectly adjusted Check settings and correct if required Room temperature see page ...

Page 40: ...check with your gas supply utility Fault is displayed Scan and acknowledge the type of fault see page 37 If necessary notify your heating contractor The DHW is too hot Cause Remedy The remote control is incorrectly adjus ted Check the set DHW temperature and cor rect if required see page 26 ã flashes and Fault is displayed Cause Remedy Heating system fault Proceed as described on page 37 ë flashes...

Page 41: ...ause Remedy The operating program has been changed by the Vitocom communication interface You can change the operating program Follow the instructions in the menu Ext set room temperature is displayed Cause Remedy A set room temperature has been input via the Vitocom communication interface You can change the standard room tem perature see page 19 This will cancel the external hook up and are disp...

Page 42: ...Insert the batteries see next chapter is displayed Cause Remedy Batteries are faulty Change the batteries see next chapter Changing the batteries Use batteries of the type Mignon NiMH AA HR6 2100 mAh 1 2 V What to do if flashes 5592 245 GB ...

Page 43: ... display will start up when the batter ies are inserted The display may take up to 5 min to start up Heating circuit selection Heating circuit 2 Heating circuit 3 id After starting up the standard menu appears What to do if Changing the batteries cont 5592 245 GB ...

Page 44: ...44 Disposal Always dispose of spent batteries via an authorised collection site What to do if Changing the batteries cont 5592 245 GB ...

Page 45: ...ouring Clean the sur face of the programming unit with the microfibre cloth provided Redecorating If you redecorate make sure that you are able to keep the table top dock wall mounting bracket in the same place Never use wallpaper containing metal foil laminated wallpaper Servicing Servicing 5592 245 GB ...

Page 46: ...ate time Select language Standard setting Display settings Reset data to zero General Heating circuit 1 Heating circuit 2 DHW Solar Time program DHW circulation Set DHW temperature Time program DHW Heating circuit 3 Detailed scan options see following page Solar energy DHW Configuration Appendix Menu overview 5592 245 GB ...

Page 47: ...erature Red set room temperature Ext set room temperature Set party temperature Flow temperature Holiday program DHW Time program DHW HC1 Time program DHW HC2 Time program DHW HC3 Time program DHW circulation HC1 Time program DHW circulation HC2 Time program DHW circulation HC3 DHW temperature DHW temperature top DHW temp bottom Cylinder primary pump DHW circulation Solar Collector temperature Sol...

Page 48: ...m Heating and DHW the operating status changes from Standard heating mode see page 49 to reduced heating mode see page 49 and vice versa The times for the operating status change over are defined by you when setting the time program Heating circuit A heating circuit is a sealed circuit between the boiler and radiators in which the heating water circulates A heating system may comprise several heat...

Page 49: ...e see page 19 See also Reduced heating mode Solar circuit pump In conjunction with solar thermal sys tems The solar circuit pump delivers the cooled heat transfer medium from the DHW cylinder indirect coil to the collec tors Set temperature Default temperature that should be reached e g set DHW temperature Summer mode Operating program Only DHW During the warmer months of the year i e if the rooms...

Page 50: ...The DHW circulation pump transports the DHW around a ring pipeline between the DHW cylinder and the draw off points e g hot tap This makes hot water available quickly at the draw off point Appendix Terminology cont 5592 245 GB ...

Page 51: ...ating outside the time pro gram 29 DHW temperature setting 26 Display backlighting 33 Display elements 9 E Economy mode Enabling 23 Terminating 24 Energy saving Economy mode 23 Holiday program 24 Energy saving function Economy mode 23 Holiday program 24 Extended menu 13 External hook up 41 External program 41 External set room temperature 41 F Factory setting 7 Fault message 11 Acknowledging 37 Ca...

Page 52: ...n Controls 9 Sequence 14 P Party mode Enabling 23 Terminating 23 Power failure 7 Pre setting at factory 7 Programming unit 9 Programs setting For central heating 20 For DHW circulation pump 29 For DHW heating 27 Pump Cylinder 49 DHW circulation 50 Heating circuit 48 Solar circuit 49 R Reduced heating mode 7 19 49 Reduced room temperature night set back 7 19 49 Reset 33 Restoring factory settings 3...

Page 53: ...am 25 Summer mode 22 48 49 Summertime changeover 7 Symbols on the display 9 T Temperature Actual temperature 48 DHW 26 Reduced room temperature 19 Scanning 35 Set temperature 49 Standard room temperature 12 19 Terminology 8 47 Time 32 Time phase deleting For central heating 22 For DHW circulation pump 30 For DHW heating 29 Time phase setting For central heating 20 For DHW circulation pump 29 For D...

Page 54: ...54 5592 245 GB ...

Page 55: ...55 5592 245 GB ...

Page 56: ...nd local contractors on the internet under www viessmann com Viessmann Limited Hortonwood 30 Telford Shropshire TF1 7YP GB Telephone 44 1952 675000 Fax 44 1952 675040 E mail info uk viessmann com Viessmann Werke GmbH Co KG D 35107 Allendorf Telephone 49 6452 70 0 Fax 49 6452 70 2780 www viessmann com 5592 245 GB Subject to technical modifications ...

Reviews: