background image

FAUCET SPECIFICATIONS

Vessel Bathroom Faucet

Model VG03024

MODEL #

FAUCET

SPOUT                      HOLE

HEIGHT

REACH                      DIAMETER

VG03024

10 1/2"

 5 1/4"                            1 3/8"

DIMENSIONS

MODEL VG03024

FEATURES

Solid brass construction
Single hole construction
Ceramic disk cartridge
Single lever faucet
Standard plumbing connections
Finish resist corrosion and tarnishing

PACKING LIST

Faucet Assembly
Brass ring
Rubber washer
Two Metal braided hoses
Nut

5 1/4"

10 1/2"

NOTE: All faucets are compliant to CEC 2016 regulations.  If you
have inquiries about your water flow, please email

techmail@vigoindustries.com.

Summary of Contents for VG03024

Page 1: ...nstruction Single hole construction Ceramic disk cartridge Single lever faucet Standard plumbing connections Finish resist corrosion and tarnishing PACKING LIST Faucet Assembly Brass ring Rubber washer Two Metal braided hoses Nut 5 1 4 10 1 2 NOTE All faucets are compliant to CEC 2016 regulations If you have inquiries about your water flow please email techmail vigoindustries com ...

Page 2: ...THE MEASUREMENTS IN INCHES ARE ROUNDED TO THE NEAREST 1 8 VG03024 6 TOP VIEW SIDE VIEW FRONT VIEW 5 1 4 10 1 2 3 1 2 8 2 1 5 8 2 1 5 8 1 3 4 2 ...

Page 3: ...o modifying Vigo is not responsible for any alterations and the affects that may come with altering the product post sale and highly advises that the client only install the product that meets the needs of their local plumbing code Flow rate with restrictors 1 2 gpm Flow rate without restrictors 1 5 gpm FLOW RATE REGULATIONS You will find the 1 2 gpm restrictors here Simply remove the 1 2 gpm rest...

Page 4: ...second wrench to tighten the nut one additional turn Connections that are too tight will reduce the integrity of the system Wrap all threaded connections with Teflon tape available at your local hardware or plumbing supply store Always wrap in a clockwise direction All installations can vary depending on how your previous faucet was installed Not all necessary supplies to install your faucet are i...

Page 5: ... tape 2 B Remove supply lines and flush lines 2 A Remove aerator and soak clean with a non abrasive agent i e half hot water and half vinegar 1 B Contact Vigo Technical Support for replacement 1 A Remove cartridge from housing wash thoroughly with hot water and reseat in housing 3 B Remove supply line and check the status of the washer If torn washer must be replaced for a secure non leaking conne...

Page 6: ...h access is not available all expenses to provide said access will be the responsibility of the owner This warranty does not apply to Products that have not been installed or operated in accordance with instructions supplied by VIGO and all applicable rules regulations and legislation pertaining to such installations This warranty does not apply unless the VIGO Product is installed by fully insure...

Page 7: ... MODEL VG03024 FEATURES Solid brass construction Single hole construction Ceramic disk cartridge Single lever faucet Standard plumbing connections Finish resist corrosion and tarnishing PACKING LIST Faucet Assembly Brass ring Rubber washer Two Metal braided hoses Nut 10 1 2 5 1 4 de la CEC de 2016 Si vous avez des questions au sujet de votre ...

Page 8: ...THE MEASUREMENTS IN INCHES ARE ROUNDED TO THE NEAREST 1 8 VG03024 6 TOP VIEW SIDE VIEW FRONT VIEW 5 1 4 10 1 2 3 1 2 8 2 1 5 8 2 1 5 8 1 3 4 2 ...

Page 9: ...peut venir avec la modification du poste de vente de produits et Vous trouverez les 1 2 restricteurs gpm ici Il suffit de retirer les 1 2 restricteurs gpm et installer le robinet comme d habitude Restricteur 1 2gpm restricteur Robinet 1 2gpm restricteur ...

Page 10: ...second wrench to tighten the nut one additional turn Connections that are too tight will reduce the integrity of the system Wrap all threaded connections with Teflon tape available at your local hardware or plumbing supply store Always wrap in a clockwise direction All installations can vary depending on how your previous faucet was installed Not all necessary supplies to install your faucet are i...

Page 11: ... tape 2 B Remove supply lines and flush lines 2 A Remove aerator and soak clean with a non abrasive agent i e half hot water and half vinegar 1 B Contact Vigo Technical Support for replacement 1 A Remove cartridge from housing wash thoroughly with hot water and reseat in housing 3 B Remove supply line and check the status of the washer If torn washer must be replaced for a secure non leaking conne...

Page 12: ...h access is not available all expenses to provide said access will be the responsibility of the owner This warranty does not apply to Products that have not been installed or operated in accordance with instructions supplied by VIGO and all applicable rules regulations and legislation pertaining to such installations This warranty does not apply unless the VIGO Product is installed by fully insure...

Page 13: ...ion Single hole construction Ceramic disk cartridge Single lever faucet Standard plumbing connections Finish resist corrosion and tarnishing PACKING LIST Faucet Assembly Brass ring Rubber washer Two Metal braided hoses Nut 10 1 2 5 1 4 NOTA Todos los grifos cumplen con CEC 2016 regulaciones Si usted tiene preguntas acerca de su flujo de agua por favor escriba techmail vigoindustries com ...

Page 14: ...THE MEASUREMENTS IN INCHES ARE ROUNDED TO THE NEAREST 1 8 VG03024 6 TOP VIEW SIDE VIEW FRONT VIEW 5 1 4 10 1 2 3 1 2 8 2 1 5 8 2 1 5 8 1 3 4 2 ...

Page 15: ... flujo con restrictores 1 2 gpm La velocidad de flujo sin restrictores 1 5 gpm NORMAS DE CAUDAL quitar los restrictores de 1 2 gpm e instalar el grifo como de costumbre Restrictor Limitador 1 2gpm Grifo Limitador 1 2gpm ...

Page 16: ...second wrench to tighten the nut one additional turn Connections that are too tight will reduce the integrity of the system Wrap all threaded connections with Teflon tape available at your local hardware or plumbing supply store Always wrap in a clockwise direction All installations can vary depending on how your previous faucet was installed Not all necessary supplies to install your faucet are i...

Page 17: ... tape 2 B Remove supply lines and flush lines 2 A Remove aerator and soak clean with a non abrasive agent i e half hot water and half vinegar 1 B Contact Vigo Technical Support for replacement 1 A Remove cartridge from housing wash thoroughly with hot water and reseat in housing 3 B Remove supply line and check the status of the washer If torn washer must be replaced for a secure non leaking conne...

Page 18: ...h access is not available all expenses to provide said access will be the responsibility of the owner This warranty does not apply to Products that have not been installed or operated in accordance with instructions supplied by VIGO and all applicable rules regulations and legislation pertaining to such installations This warranty does not apply unless the VIGO Product is installed by fully insure...

Reviews: