Existing Line Or Securely Operate Multiple Door Strikes 

Features

The 

C-2000B

offers two operational modes for  flexibility

in operation.

In the Single Line Ring Through Mode, the 

C-2000B

allows single line phones to share a phone line with 1 to
4 entry phones.  Tenants may converse with visitors and
activate a contact closure to control gates or strikes. The

C-2000B

provides entry phone “Caller ID” and “Call

Waiting Caller ID” and a “Call Waiting” tone when the
phone line is in use.  Tenants can enter at each location
by entering a keyless entry code.

In the Analog Station Dial Through Mode, the 

C-2000B

allows 1 to 4 entry phones to share one analog PABX
extension or telephone line and place outgoing calls.
When a remote party answers, they can converse with
visitors and activate a contact closure to control gates or
strikes.  Monitoring entry phones, forcing door strike relays
to operate or remote programming of the 

C-2000B

can be

accomplished by calling the analog PABX extension or
telephone line connected.  Authorized personnel can enter
at each location by entering a keyless entry code.

In either operational mode, the secure relay control of the

C-2000B

prevents the entry phone from dialing the

activation code on the keypad of the entry phone or using
a hand held touch tone dialer.  An auxiliary input is
available for connecting a lighted doorbell switch, a
common garage door opener/receiver or an auxiliary
keyless entry keypad.

•  Allows 1-4 entry phones to share a single telephone line

with a residential or business telephone system

•  Compatible with the following Viking entry phones:

E-10A

E-20B

E-30

,

E-35

,

E-40

E-50

E-60

,

E-65

,

E-70

, and 

E-75

Phones

K-1500-7

Stainless Steel Panel Phone

K-1700-3

and 

K-1705-3

Phone with Keypad

K-1900-8

Stainless Steel Panel Phone with Keypad

- Or use with any analog touch tone phone

•  Provides entry phone activated chimes and whole house

paging when used with an

SLP-1 

or

SLP-4

•  Up to 6 different keyless entry codes / “one time use”

keyless entry codes per entrance

•  Up to 6 master keyless entry codes for use at any entry

•  Analog Station Dial Through Mode allows entry phones to

connect to an analog PABX station or telephone line

•  Optional “Privacy Number” allows only selected visitors to

call from an entry phone          

•  Provides “Caller ID” and “Call Waiting Caller ID”

•  Produces “Call Waiting” tones

•  Programmable entry phone Caller ID messages

•  Lighted doorbell switch input to activate entry phone call

•  One set of normally open and normally closed contacts

available for each entry phone

•  Programmable door strike activation code

•  Programmable contact activation time

•  Auxiliary input to activate timed auxiliary contacts

•  Add one to four entry phones to your standard home or

office phones to provide:

- Door communication
- Door entry
- Gate entry
- Keyless entry

•  Provide commercial or residential security via two-way

handsfree communication at the door and gate

•  Connects in series with a single phone line or to a

phone system’s unused line input (loop start trunk input)

•  High security building entry systems

•  Door strikes and gates in conjunction with entry phones

or hot-line/panel phones

Power: 

120VAC / 13.8VAC 1.25A, UL listed adapter provided

Dimensions: 

210mm x 159mm x 45mm (8.25" x 6.25" x 1.75")

Shipping weight: 

1.5kg (3.2 lbs.)

Environmental:  

0°C to 32°C (32°F to 90°F) with 5% to 95%

non-condensing humidity

Relay Contacts: 

5A @ 30VDC/250VAC

Ring Output: 

8 REN, capable of ringing (16) 0.5 REN phones

Talk Battery:

40V DC

REN: 

0.1A

Connections: 

(32) cage clamp screw terminals

C-2000B

Advanced Door/Gate

Entry Phone Controller

September 20, 2017

Applications

Specifications

www.VikingElectronics.com

Information: (715) 386-8861

VIKING

Summary of Contents for C-2000B

Page 1: ...65 E 70 and E 75 Phones K 1500 7 Stainless Steel Panel Phone K 1700 3 and K 1705 3 Phone with Keypad K 1900 8 Stainless Steel Panel Phone with Keypad Or use with any analog touch tone phone Provides e...

Page 2: ...Analog Station Mode DIP switch 5 ON DIP Switches see page 9 Power Input 13 8VAC 1 25A adapter included Note The C 2000B is not recommended to be installed in combination with the TR 1 Toll Restrictor...

Page 3: ...Stations E 10A E 60 E 40 K 1700 3 Ring Gen Ring Gen Ring Gen Ring Gen Ring Gen Ring Gen Ring Gen Ring Gen Note Keypads used for keyless entry only Note A C O line is not required but the unit must be...

Page 4: ...Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the telephone line It is recommended that a surge protector be installed to protect agai...

Page 5: ...G CO LINE INPUT GND OUT TO PHONES USB USB TRIG 1 TRIG 2 TRIG 3 TRIG 4 MSG MSG MSG MSG POWER PAGE MUTE AUDIO PAGE LOUD RING IO COM SPK OUTPUT C O Phone Line DIP Switch 1 must be ON DIP Switches 1 and 5...

Page 6: ...OR STRIKE 1 ENTRY PHONE 2 DOOR STRIKE 2 ENTRY PHONE 3 DOOR STRIKE 3 ENTRY PHONE 4 DOOR STRIKE 4 DOORBELL SWITCH AUX INPUT AUX CONTACT OUTPUT PHONE LINE INPUT LINE OUT TO PHONES ANALOG STATION INPUT ST...

Page 7: ...double beep will indicate that you have accessed the programming mode Step 4 You can now touch tone program the features listed in section B Step 5 When finished programming hang up and move DIP switc...

Page 8: ...es factory disabled 4 6 digits 0 9 Q 51 Q 56 Door strike 1 activation time 5 99 seconds factory set to 5 seconds 2 digits 00 99 19 Door strike 2 activation time 5 99 seconds factory set to 5 seconds 2...

Page 9: ...Mode 3 OFF Entry Phone automatic disconnect CPC disabled Note Viking handsfree entry phones require CPC for faster automatic disconnect 3 ON Entry Phone automatic disconnect CPC enabled factory settin...

Page 10: ...ill be called automatically answer see the Product Manual for your entry phone and begin ringing the house phones terminals 4 and 5 LINE OUT TO PHONES The house phones can then be answered door strike...

Page 11: ...eyless codes programmed for an entry phone and not master codes If a master keyless code is entered with Global Keyless Entry enabled the C 2000B will activate the relay for the entry phone the user i...

Page 12: ...D displays may not be compatible with certain characters Entry phone calls are factory set to ring the house phones in a custom double ring cadence 7 seconds on 3 seconds off 7 seconds on then 4 secon...

Page 13: ...cepted when the house phones pick up and is the first digit dialed Entry Phone Caller ID and Call waiting ID 1 Entry Phone 1 2 Entry Phone 2 3 Entry Phone 3 4 Entry Phone 4 C Activating Door Strike Ga...

Page 14: ...e designed for intermittent operation only The latch and toggle commands should NOT be used with these intermittent strikes or damage to the strike may occur Only use the latch and toggle commands wit...

Page 15: ...odes and or manually dialing extensions K 1700 3 K 1705 3 K 1900 8 K 1700 3 BN D10 Directory Any Analog Touch Tone Phone Entry phones with built in auto dialers for phone systems without ringdown capa...

Page 16: ...ECORDABLE TRIGGERED AUDIO CHIMES MESSAGES POWER 13 8 VAC USB LED POWER MUTE AUDIO PAGE PAGE TRIGGER OUTPUT WET 12VDC DRY N C COM N O WAVE FILE INPUT TRIGGERED AUDIO CHIME MESSAGE SELECTIONS PER TRIGGE...

Page 17: ...16 Entry phone 1 one time use keyless entry codes factory disabled 4 6 digits 0 9 Q 11 Q 16 Entry phone 2 keyless entry codes factory disabled 4 6 digits 0 9 21 26 Entry phone 2 one time use keyless e...

Page 18: ...ollowed by 47 If you have forgotten your security code follow the steps in Programming section A 2 Accessing the Programming Mode Locally Security Code Bypass Mode Note The security code must be six d...

Page 19: ...QQ To disable this feature enter 57 without any preceding digits The C 2000B determines which direction the touch tone is coming from and only responds to touch tones from the called phone The factory...

Page 20: ...he auxiliary relay during the monitor once the entry phone answers so a camera or light can be activated while monitoring Auxiliary Contact Programming DIP switch 1 OFF Enter Digits Location Auxiliary...

Page 21: ...aximum Entry Phone Ring Count on page 20 the C 2000B stops ringing that entry phone and remains in the programming mode for up to 20 seconds ready for another C 2000B program command When the entry ph...

Page 22: ...the relay A short buzz will indicate the door strike relay is off In this mode no caller ID data is generated by the controller and no entry phone identifier beeps are provided when the call is answe...

Page 23: ...the door Keyless entry codes also affect the operation of the auxiliary relay contacts if the auxiliary contacts have been programmed to trigger when an entry phone has gone off hook This is when DIP...

Page 24: ...ODUCT SOLD HEREUNDER EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY WHETHER IN AN ACTION BASED ON CONTRACT TORT INCLUDING NEGLIGENCE OR STRICT LIABILITY OR ANY OTHER LEGAL THEORY ANY LIABILITY OF VIKING...